Permit Details

Status:
Expired
Type:
Residential Building - One or Two Family
Apply Date:
08/09/2018
Applicant:
Timothy Robertson
Description:
ADD MASTER BEDROOM AND REC ROOM

Permit Reviews

Permit Number - T18CM06233
Permit Status: Expired
Permit Description: ADD MASTER BEDROOM AND REC ROOM
Start Date Submittal Complete Date Status  
08/09/2018 RESIDENTIAL - BLDG/ZONING-WALKTHRU 08/09/2018 COMPLETED Review Details
09/04/2018 RESIDENTIAL - BLDG/WWM 09/12/2018 COMPLETED Review Details
09/12/2018 RESIDENTIAL - BLDG/WWM 09/28/2018 COMPLETED Review Details
10/23/2018 REVISION - - 1ST 12/07/2018 COMPLETED Review Details
12/07/2018 REVISION - - 2ND 12/07/2018 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T18CM06233
Permit Status: Expired
Permit Description: ADD MASTER BEDROOM AND REC ROOM
Total Outstanding Activity Conditions - 1
Date Name
08/09/2018 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Conditions

Permit Number - T18CM06233
Permit Status: Expired
Permit Description: ADD MASTER BEDROOM AND REC ROOM
Date Description Comments
09/04/2018 ROOF TRUSSES MUST BE APPROVED PRIOR TO FRAMING INSPECTION (P2I)

Completed Inspections

Permit Status: Expired
Permit Number: T18CM06233
Permit Description: ADD MASTER BEDROOM AND REC ROOM
Total Completed Inspections - 18
Date Description Inspector Results Comments
12/12/2018 COT - RSBU - Preslab Passed {Activity date: 12/12/2018; Status: Approved; Inspector: RCAMACHO; Comment: Entered by CBELL1 - } ; {Activity date: 10/29/2018; Status: Denied; Inspector: RCAMACHO; Comment: Entered by CBELL1 - Missing f-2 footers south garage wall
Missing holddowns south garage wall
Except f-2footers south deck} ; {Activity date: 10/26/2018; Status: Denied; Inspector: ESTEVENS; Comment: Entered by CBELL1 - 3 inch clearance required from rebar to earth. Center footing is two, F-2 footings. Rebar is required at corners}
12/12/2018 COT - RSBU - Excavation/Rebar/Zoning Passed {Activity date: 12/12/2018; Status: Approved; Inspector: RCAMACHO; Comment: Entered by CBELL1 - } ; {Activity date: 12/11/2018; Status: Approved; Inspector: DMCCARTHY; Comment: Entered by CBELL1 - for two piers-caisson at the front entry area. Not for main structure addition.} ; {Activity date: 10/29/2018; Status: Denied; Inspector: RCAMACHO; Comment: Entered by CBELL1 - Missing f-2 footers south garage wall
Missing holddowns south garage wall
Except f-2footers south deck} ; {Activity date: 10/26/2018; Status: Denied; Inspector: ESTEVENS; Comment: Entered by CBELL1 - 3 inch clearance required from rebar to earth. Center footing is two, F-2 footings. Rebar is required at corners}
12/14/2018 COT - RSBU - Roof Nailing Passed {Activity date: 12/14/2018; Status: Approved; Inspector: ESTEVENS; Comment: Entered by CBELL1 - }
12/14/2018 COT - RSPL - Gas Pressure Test Passed {Activity date: 12/14/2018; Status: Approved; Inspector: ESTEVENS; Comment: Entered by CBELL1 - }
12/17/2018 COT - BULD - SWG Clearance Passed {Activity date: 12/17/2018; Status: Approved; Inspector: ESTEVENS; Comment: Entered by CBELL1 - }
02/07/2019 RSEL - Electrical Progress Passed {Activity date: 02/07/2019; Status: Approved; Inspector: TVALENCIA; Comment: Entered by CBELL1 - }
02/11/2019 COT - LCBU - Framing Passed {Activity date: 02/11/2019; Status: Approved; Inspector: TVALENCIA; Comment: Entered by CBELL1 - } ; {Activity date: 02/08/2019; Status: Not ready for Inspection; Inspector: TVALENCIA; Comment: Entered by CBELL1 - Work is incomplete} ; {Activity date: 02/07/2019; Status: Denied; Inspector: TVALENCIA; Comment: Entered by CBELL1 - 1- Shall seal all top plate penetrations with fire rated foam or caulk.
2- Shall provide blocking at all horizontal sanitary vents every 5 feet.
3- Shall provide (3) sided blocking at all forced air vents.} ; {Activity date: 12/20/2018; Status: Not ready for Inspection; Inspector: DMCCARTHY; Comment: Entered by CBELL1 - Required inspections still need before 1035 Framing can be signed off.
Required inspections still need before 1035 Framing can be signed off.

2035 electric intermediate
3035 plumbing intermediate
All trades complete inside wall and floor diaphragm. Then framing inspection, 1035.
1035, 2035, 3035, all at the same}
02/15/2019 COT - RSEL - Service Relocation Passed {Activity date: 02/15/2019; Status: Approved; Inspector: MHASSAN; Comment: Entered by CBELL1 - OK to clear electric INCR this is a cut over from existing to new panel.}
02/15/2019 PDSD Building Division - TEP PM Clearance Passed {Activity date: 02/15/2019; Status: Approved; Inspector: MHASSAN; Comment: Entered by CBELL1 - CODE INCR}
02/15/2019 COT - LCPL - Plumbing Intermediate Passed {Activity date: 02/15/2019; Status: Approved; Inspector: MHASSAN; Comment: Entered by CBELL1 - } ; {Activity date: 02/07/2019; Status: Denied; Inspector: TVALENCIA; Comment: Entered by CBELL1 - 1-Shall provide a trap and vent for the 2nd floor shower.}
02/15/2019 COT - RSBU - Exterior Clips/Sheathing Passed {Activity date: 02/15/2019; Status: Approved; Inspector: MHASSAN; Comment: Entered by CBELL1 - }
02/15/2019 RSME - Mechanical Progress Passed {Activity date: 02/15/2019; Status: Approved; Inspector: MHASSAN; Comment: Entered by CBELL1 - } ; {Activity date: 02/07/2019; Status: Denied; Inspector: TVALENCIA; Comment: Entered by CBELL1 - } ; {Activity date: 09/04/2018; Status: Prior to Intermediates; Inspector: KEN; Comment: Entered by KKARSEN1 - MANUAL J-D-S REPORT MUST BE APPROVED PRIOR TO INSPECTION}
03/25/2019 COT - RSME - Mechanical Final Passed {Activity date: 03/25/2019; Status: Approved; Inspector: TVALENCIA; Comment: Entered by CBELL1 - }
03/25/2019 RSBU - Building Final Passed {Activity date: 03/25/2019; Status: Approved; Inspector: TVALENCIA; Comment: Entered by CBELL1 - } ; {Activity date: 02/15/2019; Status: Not ready for Inspection; Inspector: MHASSAN; Comment: Entered by CBELL1 - stairs up to second floor addition need to be fixed and made to code before final.}
03/25/2019 COT - RSEL - Outdoor Lighting Passed {Activity date: 03/25/2019; Status: Approved; Inspector: TVALENCIA; Comment: Entered by CBELL1 - }
03/25/2019 COT - RSPL - Plumbing Final Passed {Activity date: 03/25/2019; Status: Approved; Inspector: TVALENCIA; Comment: Entered by CBELL1 - }
03/25/2019 COT - RSPL - Rough Soil Passed {Activity date: 03/25/2019; Status: Approved; Inspector: TVALENCIA; Comment: Entered by CBELL1 - approved upon 3090 approval from TVALENCIA} ; {Activity date: 10/18/2018; Status: Partial Approval; Inspector: RCAMACHO; Comment: Entered by CBELL1 - 4" main under new garage only} ; {Activity date: 10/17/2018; Status: Not ready for Inspection; Inspector: MRAMBER; Comment: Entered by CBELL1 - Plan calls for 3" waste, 4" is installed, DWV not on test} ; {Activity date: 10/15/2018; Status: Denied; Inspector: ESTEVENS; Comment: Entered by VFLORES1 - No access to garage plumbing, P2604.3, backfill shall be free from rocks. No contractor contact number.}
03/25/2019 COT - RSEL - Electrical Final Passed {Activity date: 03/25/2019; Status: Approved; Inspector: TVALENCIA; Comment: Entered by CBELL1 - }

Documents

File Name Document Type  
001_A1.1.TIF CONSTRPLANS VIEW
002_A2.0.TIF CONSTRPLANS VIEW
003_A2.1.TIF CONSTRPLANS VIEW
004_A2.2.TIF CONSTRPLANS VIEW
005_A3.1.TIF CONSTRPLANS VIEW
006_A3.2.TIF CONSTRPLANS VIEW
007_A4.1.TIF CONSTRPLANS VIEW
008_S1.1.TIF CONSTRPLANS VIEW
009_S2.1.TIF CONSTRPLANS VIEW
010_S2.2.TIF CONSTRPLANS VIEW
011_S3.1.TIF CONSTRPLANS VIEW
001_P0.1.TIF CONSTRPLANS VIEW
012_P1.1.TIF CONSTRPLANS VIEW
013_M1.1.TIF CONSTRPLANS VIEW
014_E1.1.TIF CONSTRPLANS VIEW
015_E1.2.TIF CONSTRPLANS VIEW
None DOCUMENTS VIEW
3158WSTARRPASSBLVD.PDF DOCUMENTS VIEW