Permit: T18CM02149
Permit Details
Apply Date:
03/21/2018
Applicant:
DUSTIN DIAZ
Description:
PAVILLION IMPROVEMENT
Architects:
- WATSON, ANGELA
Permit Reviews
Permit Number - T18CM02149
Permit Status: Final
Permit Description: PAVILLION IMPROVEMENT
Start Date | Submittal | Complete Date | Status |
---|---|---|---|
04/17/2018 | COMMERCIAL - TI | 05/31/2018 | COMPLETED |
06/04/2018 | RESUBMITTAL - TI ALL | 06/26/2018 | COMPLETED |
06/29/2018 | RESUBMITTAL | 06/29/2018 | COMPLETED |
07/24/2018 | RESUBMITTAL | 07/24/2018 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T18CM02149
Permit Status: Final
Permit Description: PAVILLION IMPROVEMENT
Total Outstanding Activity Conditions - 1
Date | Name |
---|---|
03/21/2018 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: Final
Permit Number: T18CM02149
Permit Description: PAVILLION IMPROVEMENT
Total Completed Inspections - 34
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
05/10/2018 | MECHANICAL - FINAL | RSHERRY | Approved | AIR BALANCE REPORT REQUIRED |
07/24/2018 | PLUMBING - FINAL | RSHERRY | Approved | WATER CHLORINATION REPORT REQUIRED |
07/26/2018 | BUILDING ABOVE CEILING | JBURGE | Approved | PHASE I COMPLETE - OK TO SET CEILING TILES. |
07/26/2018 | PLUMBING - ABOVE CEILING | JBURGE | Approved | PHASE I COMPLETE. |
09/04/2018 | STEM WALL/RETAINING WALL | JBURGE | Approved | CMU STEM WALL AT 12" - 48"; NORTH WEST CORNER OF BUILDING - OK TO GROUT PROGRESS AREAS. |
09/05/2018 | PLUMBING - PROGRESS | JBURGE | Approved | PLUMBING ROUGH SOIL: 8' ROOF DRAIN PIPE/LINE. OK TO COVER. |
09/10/2018 | MECHANICAL - HYDRONIC PIPING | JBURGE | Approved | DOMESTIC WATER LINE AT 2 1/2", HEATED HOT WATER SUPPLY AND RETURN AT 3"; CHILLED BEAM SUPPLY AND RETRUN LINES AT 3". OK TO COVER PROGRESS AREAS. |
09/25/2018 | ROOF NAILING | JBURGE | Approved | METAL DECK SYSTEM; PUDDLE WELDED. OK TO COVER. |
09/27/2018 | BUILDING PRE-SLAB | JBURGE | Approved | Main entry areas (North and Northeast), Rebar is in place. Ok to place concrete. |
10/11/2018 | EXT METAL CLIPS/EXT SHEATHING | JBURGE | Approved | West exterior wall - dens-glas system. Ok to water proof |
11/28/2018 | ELECTRIC - UNDERGROUND | JBURGE | Approved | Conduits and users for 7 light pole caisson footings. Ok to cover progress areas. |
11/28/2018 | MECHANICAL - ABOVE CEILING | JBURGE | Approved | High and low pressure duct system. Ok to insulate progress areas. |
12/03/2018 | EXCAVATION/LAYOUT REBAR & ZON | JBURGE | Approved | 8 each light pole caisson footings at West portion of site. Ok to place concrete |
12/05/2018 | PLUMBING - ROOF DRAINS | JBURGE | Approved | storm drains and over flow drains tested and corrections are complete. |
12/17/2018 | FRAMING | JBURGE | Approved | West restroom ceiling. Soffits at main entry areas, center portion of building. Ok to cover progress areas. |
12/19/2018 | ELECTRIC - INTERMEDIATE | JBURGE | Approved | Chapel area in wall electric. Ok to cover walls |
12/19/2018 | PLUMBING - INTERMEDIATE | JBURGE | Approved | 4 each 4” roof drains at North entry area. Under Hydro test - ok to drain lines |
12/26/2018 | SHEET ROCK NAILING | JBURGE | Approved | West shaft. Fire caulked and sheet rocked. Ok to place final layer of sheetrock. |
12/26/2018 | ELECTRIC - ABOVE CEILING | JBURGE | Approved | 9 Can lights in soffits in main entry areas |
12/28/2018 | PLUMBING - ROUGH, SOIL | JBURGE | Approved | EDMRE, Phase III - WASTE & Vent lines at 1 1/2" - 4" lines, Ok to cover |
03/28/2019 | FIRE - FINAL | JPEELDAVIS | Approved | |
04/05/2019 | OUTDOOR LIGHTING FINAL | JBURGE | Approved | |
04/05/2019 | ELECTRIC - FINAL | JBURGE | Approved | |
04/05/2019 | ELECTRIC - OUTDOOR LIGHTING | JBURGE | Approved | |
04/05/2019 | ELECTRIC - PROGRESS | JBURGE | Approved | |
04/05/2019 | ELECTRIC - CONSTRUCTION POWER | JBURGE | Approved | |
04/05/2019 | ELECTRIC - TEMPORARY SERVICE | JBURGE | Approved | |
04/05/2019 | ELECTRIC - UFER | JBURGE | Approved | |
04/05/2019 | BUILDING - PROGRESS | JBURGE | Approved | |
04/05/2019 | FIREWALL/FIREBARRIER/FIRESTOP | JBURGE | Approved | |
04/05/2019 | U VALUE FOR WINDOW | JBURGE | Approved | |
04/05/2019 | REINFORCED MASONRY PRE-GROUT | JBURGE | Approved | |
04/05/2019 | MECHANICAL - INTERMEDIATE | JBURGE | Approved | |
09/09/2019 | BUILDING - FINAL | JBURGE | Approved | PENDING ENGINEERING FINAL |