Permit Details

Status:
Final
Type:
SINGLE FAMILY NEW
Address:
1815 E 9TH ST
Apply Date:
12/01/2017
Applicant:
MARAK ARTHUR GENE JR
Description:
DETACHED QUARTERS

Permit Reviews

Permit Number - T17CM08867
Permit Status: Final
Permit Description: DETACHED QUARTERS
Start Date Submittal Complete Date Status  
03/26/2018 RESIDENTIAL - BLDG/WWM 04/25/2018 COMPLETED Review Details
12/01/2017 PLANS OK TO SUBMIT - RES 03/16/2018 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T17CM08867
Permit Status: Final
Permit Description: DETACHED QUARTERS
Total Outstanding Activity Conditions - 1
Date Name
12/01/2017 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Completed Inspections

Permit Status: Final
Permit Number: T17CM08867
Permit Description: DETACHED QUARTERS
Total Completed Inspections - 22
Date Description Inspector Results Comments
04/10/2018 MECHANICAL - INTERMEDIATE KEN Approved SUBMIT MANUAL J-D-S REPORT BEFORE MECH INSP
10/03/2018 PLUMBING - YARD WTR LINE/TEST BSTEVENS Approved
10/23/2018 PLUMBING - ROUGH, SOIL GWEST Approved
10/23/2018 ELECTRIC - UNDERGROUND GWEST Approved
10/25/2018 ELECTRIC - UFER GWEST Approved
10/25/2018 BUILDING PRE-SLAB GWEST Approved
10/25/2018 EXCAVATION/LAYOUT REBAR & ZON GWEST Approved
12/20/2018 ROOF NAILING DMCCARTHY Approved Residential detached addition roof nail inspection only
In line construction general contractor commercial TI
01/16/2019 EXT METAL CLIPS/EXT SHEATHING MHASSAN Approved
01/23/2019 PLUMBING - INTERMEDIATE mhassan Approved
01/23/2019 FRAMING mhassan Approved
01/23/2019 PLUMBING - INTERMEDIATE TVALENCIA Approved 1- Shall provide the required shield plate for the sole plate at the 3 inch waste and vent pipe.
2- Shall provide a block support for the 2 inch horizontal vent for the kitchen sink.
3- Shall provide a minimum of 12 inch separation of the water line from the can light.
4- Shall provide a sanitary tee for the lavatory trap arm.
5- Shall provide a minimum is two times the pipe size diameter of trap arm distance on clothes washer.
6- Re test on he DWV system.
01/23/2019 FRAMING TVALENCIA Approved 1- Shall provide the required shield plate for the sole plate at the 3 inch waste and vent pipe.
2- Shall provide a block support for the 2 inch horizontal vent for the kitchen sink.
3- Shall provide a minimum of 12 inch separation of the water line from the can light.
4- Shall provide a sanitary tee for the lavatory trap arm.
5- Shall provide a minimum is two times the pipe size diameter of trap arm distance on clothes washer.
6- Re test on he DWV system.
04/03/2019 STUCCO MESH RCHANDLER Approved
04/03/2019 ELECTRIC - INTERMEDIATE RCHANDLER Approved Clearance TEP-INCR. Customer is installing new 200 amp service at guest quarters, and feeding back to existing service which will become a sub-panel with meter socket blanked. This change to revised plans accommodates TEP’s request to re-route existing overhead conductors that are now in violation of clearance requirements due to proximity to new structure. Builder will run feeders of 1/0 copper with 150 amp breaker, which meets Code.
04/22/2019 TEP CLEARANCE - AM RCHANDLER Approved CODE INCR (SENT FOR 4/3)
08/22/2019 OUTDOOR LIGHTING FINAL ESTEVENS Approved
08/22/2019 PLUMBING - GAS PRESSURE TEST ESTEVENS Approved
08/22/2019 ELECTRIC - FINAL ESTEVENS Approved
08/28/2019 MECHANICAL - FINAL ESTEVENS Approved
08/28/2019 PLUMBING - FINAL ESTEVENS Approved
08/28/2019 BUILDING - FINAL ESTEVENS Approved

Documents

File Name Document Type  
001_A1.0.TIF CONSTRPLANS VIEW
002_A2.0.TIF CONSTRPLANS VIEW
003_A3.0.TIF CONSTRPLANS VIEW
004_S1.1.TIF CONSTRPLANS VIEW
005_S1.2.TIF CONSTRPLANS VIEW
006_M1.0.TIF CONSTRPLANS VIEW
007_P1.0.TIF CONSTRPLANS VIEW
008_P2.0.TIF CONSTRPLANS VIEW
009_MP1.1.TIF CONSTRPLANS VIEW
010_E1.0.TIF CONSTRPLANS VIEW
None DOCUMENTS VIEW