Permit: T17CM08867
Permit Details
Apply Date:
12/01/2017
Applicant:
MARAK ARTHUR GENE JR
Description:
DETACHED QUARTERS
Permit Reviews
Permit Number - T17CM08867
Permit Status: Final
Permit Description: DETACHED QUARTERS
Start Date | Submittal | Complete Date | Status |
---|---|---|---|
03/26/2018 | RESIDENTIAL - BLDG/WWM | 04/25/2018 | COMPLETED |
12/01/2017 | PLANS OK TO SUBMIT - RES | 03/16/2018 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T17CM08867
Permit Status: Final
Permit Description: DETACHED QUARTERS
Total Outstanding Activity Conditions - 1
Date | Name |
---|---|
12/01/2017 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: Final
Permit Number: T17CM08867
Permit Description: DETACHED QUARTERS
Total Completed Inspections - 22
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
04/10/2018 | MECHANICAL - INTERMEDIATE | KEN | Approved | SUBMIT MANUAL J-D-S REPORT BEFORE MECH INSP |
10/03/2018 | PLUMBING - YARD WTR LINE/TEST | BSTEVENS | Approved | |
10/23/2018 | PLUMBING - ROUGH, SOIL | GWEST | Approved | |
10/23/2018 | ELECTRIC - UNDERGROUND | GWEST | Approved | |
10/25/2018 | ELECTRIC - UFER | GWEST | Approved | |
10/25/2018 | BUILDING PRE-SLAB | GWEST | Approved | |
10/25/2018 | EXCAVATION/LAYOUT REBAR & ZON | GWEST | Approved | |
12/20/2018 | ROOF NAILING | DMCCARTHY | Approved | Residential detached addition roof nail inspection only In line construction general contractor commercial TI |
01/16/2019 | EXT METAL CLIPS/EXT SHEATHING | MHASSAN | Approved | |
01/23/2019 | PLUMBING - INTERMEDIATE | mhassan | Approved | |
01/23/2019 | FRAMING | mhassan | Approved | |
01/23/2019 | PLUMBING - INTERMEDIATE | TVALENCIA | Approved | 1- Shall provide the required shield plate for the sole plate at the 3 inch waste and vent pipe. 2- Shall provide a block support for the 2 inch horizontal vent for the kitchen sink. 3- Shall provide a minimum of 12 inch separation of the water line from the can light. 4- Shall provide a sanitary tee for the lavatory trap arm. 5- Shall provide a minimum is two times the pipe size diameter of trap arm distance on clothes washer. 6- Re test on he DWV system. |
01/23/2019 | FRAMING | TVALENCIA | Approved | 1- Shall provide the required shield plate for the sole plate at the 3 inch waste and vent pipe. 2- Shall provide a block support for the 2 inch horizontal vent for the kitchen sink. 3- Shall provide a minimum of 12 inch separation of the water line from the can light. 4- Shall provide a sanitary tee for the lavatory trap arm. 5- Shall provide a minimum is two times the pipe size diameter of trap arm distance on clothes washer. 6- Re test on he DWV system. |
04/03/2019 | STUCCO MESH | RCHANDLER | Approved | |
04/03/2019 | ELECTRIC - INTERMEDIATE | RCHANDLER | Approved | Clearance TEP-INCR. Customer is installing new 200 amp service at guest quarters, and feeding back to existing service which will become a sub-panel with meter socket blanked. This change to revised plans accommodates TEP’s request to re-route existing overhead conductors that are now in violation of clearance requirements due to proximity to new structure. Builder will run feeders of 1/0 copper with 150 amp breaker, which meets Code. |
04/22/2019 | TEP CLEARANCE - AM | RCHANDLER | Approved | CODE INCR (SENT FOR 4/3) |
08/22/2019 | OUTDOOR LIGHTING FINAL | ESTEVENS | Approved | |
08/22/2019 | PLUMBING - GAS PRESSURE TEST | ESTEVENS | Approved | |
08/22/2019 | ELECTRIC - FINAL | ESTEVENS | Approved | |
08/28/2019 | MECHANICAL - FINAL | ESTEVENS | Approved | |
08/28/2019 | PLUMBING - FINAL | ESTEVENS | Approved | |
08/28/2019 | BUILDING - FINAL | ESTEVENS | Approved |