Permit: T17CM08867

Parcel: 124090560


Addresses:

1815 E 9TH ST


Inspection Status: Denied

Inspection History: PLUMBING - INTERMEDIATE

Permit Number - T17CM08867

Inspection Description - PLUMBING - INTERMEDIATE

Inspection Status - Denied

Date Description Inspector Results Comments
01/23/2019 PLUMBING - INTERMEDIATE Denied 1- Shall provide the required shield plate for the sole plate at the 3 inch waste and vent pipe.
2- Shall provide a block support for the 2 inch horizontal vent for the kitchen sink.
3- Shall provide a minimum of 12 inch separation of the water line from the can light.
4- Shall provide a sanitary tee for the lavatory trap arm.
5- Shall provide a minimum is two times the pipe size diameter of trap arm distance on clothes washer.
6- Re test on he DWV system.
01/23/2019 PLUMBING - INTERMEDIATE Approved
01/18/2019 PLUMBING - INTERMEDIATE Partial Approval Leak at bathroom sink area
01/16/2019 PLUMBING - INTERMEDIATE Partial Approval secure pex and ABS piping in walls where loose. ABS piping needs to be under test at time of inspection