Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Details

Status:
Issued
Type:
Residential Building - One or Two Family
Address:
4902 E 18TH ST
Address NEW:
4902 E 18TH ST
Apply Date:
07/25/2017
Applicant:
Description:
MASTER BED , BATH CLOSET, LAUNDRY, BATH, LIVING ADDITION

Permit Reviews

Permit Number - T17CM05664
Permit Status: Issued
Permit Description: MASTER BED , BATH CLOSET, LAUNDRY, BATH, LIVING ADDITION
Start Date Submittal Complete Date Status  
07/25/2017 RESIDENTIAL - BLDG/ZONING-WALKTHRU 09/26/2017 COMPLETED Review Details
09/26/2017 RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO 09/27/2017 COMPLETED Review Details
09/27/2017 RESIDENTIAL - BLDG/WWM 10/24/2017 COMPLETED Review Details
10/24/2017 RESUBMITTAL 10/24/2017 ACTIVE Review Details

Outstanding Activity Conditions

Permit Number - T17CM05664
Permit Status: Issued
Permit Description: MASTER BED , BATH CLOSET, LAUNDRY, BATH, LIVING ADDITION
Total Outstanding Activity Conditions - 1
Date Name
07/25/2017 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Conditions

Permit Number - T17CM05664
Permit Status: Issued
Permit Description: MASTER BED , BATH CLOSET, LAUNDRY, BATH, LIVING ADDITION
Date Description Comments
10/16/2017 ROOF TRUSSES MUST BE APPROVED PRIOR TO FRAMING INSPECTION (P2I)

Outstanding Inspections

Permit Status: Issued
Permit Number: T17CM05664
Permite Description: MASTER BED , BATH CLOSET, LAUNDRY, BATH, LIVING ADDITION
Total Outstanding Inspections - 3
Last Inspection Date Description Inspector Results Comments
08/30/2019 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing N/A Canceled {Activity date: 08/30/2019; Status: Not Applicable; Inspector: RCHANDLER; Comment: Entered by DMERANZ1 - }
10/27/2022 RSBU - Building Final N/A Not Ready
10/27/2022 COT - RSPL - Plumbing Final N/A Not Ready

Completed Inspections

Permit Status: Issued
Permit Number: T17CM05664
Permit Description: MASTER BED , BATH CLOSET, LAUNDRY, BATH, LIVING ADDITION
Total Completed Inspections - 16
Date Description Inspector Results Comments
11/24/2017 COT - RSPL - Rough Soil Passed {Activity date: 11/24/2017; Status: Approved; Inspector: BBENEDO1; Comment: Entered by BBENEDO1 - IVRS - Inspection :*} ; {Activity date: 11/22/2017; Status: Denied; Inspector: BBENEDO1; Comment: Entered by BBENEDO1 - IVRS - Inspection :
See detailed listing on site.| 999


*}
03/02/2018 COT - RSBU - Roof Nailing Passed {Activity date: 03/02/2018; Status: Approved; Inspector: RGREENE1; Comment: Entered by DROBERT5 - }
05/08/2018 COT - RSPL - Gas Pressure Test Passed {Activity date: 05/08/2018; Status: Approved; Inspector: MHASSAN1; Comment: Entered by MHASSAN1 - }
05/08/2018 COT - RSBU - Sustainability Passed {Activity date: 05/08/2018; Status: Approved; Inspector: MHASSAN1; Comment: Entered by MHASSAN1 - }
06/18/2018 COT - RSBU - Preslab Passed {Activity date: 06/18/2018; Status: Approved; Inspector: GWest; Comment: Entered by GWEST2 - Front Porch/Patio and Window Seat. 6-18-2018. GWest. AP} ; {Activity date: 12/08/2017; Status: Partial Approval; Inspector: RGREENE; Comment: Entered by DROBERT5 - PHASE ONE LIVING}
06/18/2018 COT - RSBU - Excavation/Rebar/Zoning Passed {Activity date: 06/18/2018; Status: Approved; Inspector: GWest; Comment: Entered by GWEST2 - Front Porch/Paio and Window Seat. 6-18-2018. GWest AP} ; {Activity date: 12/08/2017; Status: Partial Approval; Inspector: RGREENE; Comment: Entered by DROBERT5 - PHASE ONE LIVING}
08/30/2019 COT - RSME - Mechanical Final Passed {Activity date: 08/30/2019; Status: Approved; Inspector: RCHANDLER; Comment: Entered by DMERANZ1 - }
08/30/2019 COT - LCBU - Framing Passed {Activity date: 08/30/2019; Status: Approved; Inspector: RCHANDLER; Comment: Entered by DMERANZ1 - } ; {Activity date: 09/11/2018; Status: Partial Approval; Inspector: GWest; Comment: Entered by GWEST2 - Pictures to Follow. Stud at bath wall-replace with full length/full bearing. Frame in Crawl space opening at hallway. Strap corners and wall juncture that doe not have channel or dog ear tie in. Kickers at trusse go from top plate to top of truss vertical. Get criples on layout above window headers and take stress off front bedroom window by installing cripples.
}
08/30/2019 COT - LCPL - Plumbing Intermediate Passed {Activity date: 08/30/2019; Status: Approved; Inspector: RCHANDLER; Comment: Entered by DMERANZ1 - } ; {Activity date: 05/08/2018; Status: Partial Approval; Inspector: MHASSAN1; Comment: Entered by MHASSAN1 - NEED TRACER WIRE ON GAS LINE TO HOUSE, MISSING SOME NAIL PATES MAST BATH AND LAUNDRY, MISSING FEW STRAPS ON VENT LINES OVER MAST. BATH.}
08/30/2019 COT - RSPL - Yard Water Line Passed {Activity date: 08/30/2019; Status: Approved; Inspector: RCHANDLER; Comment: Entered by DMERANZ1 - } ; {Activity date: 05/08/2018; Status: Partial Approval; Inspector: MHASSAN1; Comment: Entered by MHASSAN1 - NEED TRACER WIRE}
08/30/2019 RSEL - Electrical Progress Passed {Activity date: 08/30/2019; Status: Approved; Inspector: RCHANDLER; Comment: Entered by DMERANZ1 - } ; {Activity date: 09/11/2018; Status: Partial Approval; Inspector: GWest; Comment: Entered by GWEST2 - Light and proximal switch required at exit door and in attic at crawl space opening. Secure all romex in attic at 4'OC. Secure all romex 6 " before it enters a J-Box. Receptacle required in Hallway. Smoke detectors required at hallway leading to bedroom and one in the bedroom. Bond all metal boxes with a pigtail long enough to connect to the ground wires entering th J-Boxes using metal J-Boxes. Laundry- use single Yoke receptacles at J-Boxes provided for the Washer and the Dryer.}
08/30/2019 RSME - Mechanical Progress Passed {Activity date: 08/30/2019; Status: Approved; Inspector: RCHANDLER; Comment: Entered by DMERANZ1 - } ; {Activity date: 09/11/2018; Status: Partial Approval; Inspector: GWest; Comment: Entered by GWEST2 - }
08/13/2020 COT - RSEL - Outdoor Lighting Passed {Activity date: 08/13/2020; Status: Approved; Inspector: DMUNIZ; Comment: Entered by RSALDAT1 - Approved}
08/13/2020 COT - RSEL - Electrical Final Passed {Activity date: 08/13/2020; Status: Approved; Inspector: DMUNIZ; Comment: Entered by RSALDAT1 - Approved} ; {Activity date: 02/26/2020; Status: Not ready for Inspection; Inspector: MRAMBER; Comment: Entered by SFLORES2 - Call for inspection when all finals are ready.} ; {Activity date: 02/25/2020; Status: Cancelled; Inspector: IVR USER; Comment: Entered by IVR USER - IVRS - RI canceled}
03/21/2023 RSBU - Building Final Passed
03/21/2023 COT - RSPL - Plumbing Final Passed

Documents

File Name Document Type  
None DOCUMENTS VIEW
TRUSSES.PDF DOCUMENTS VIEW
None CONSTRPLANS VIEW
001_SHEET 1.TIF CONSTRPLANS VIEW
002_SHEET 2.TIF CONSTRPLANS VIEW
003_SHEET 3.TIF CONSTRPLANS VIEW
004_SHEET 4.TIF CONSTRPLANS VIEW
005_SHEET 5.TIF CONSTRPLANS VIEW