Permit: T17CM05664

Parcel: 128120440


Addresses:

4902 E 18TH ST

Inspection Status: Passed

Inspection History: RSEL - Electrical Progress

Date Description Inspector Results Comments
08/30/2019 RSEL - Electrical Progress RCHANDLER Approved Entered by DMERANZ1 -
09/11/2018 RSEL - Electrical Progress GWest Partial Approval Entered by GWEST2 - Light and proximal switch required at exit door and in attic at crawl space opening. Secure all romex in attic at 4'OC. Secure all romex 6 " before it enters a J-Box. Receptacle required in Hallway. Smoke detectors required at hallway leading to bedroom and one in the bedroom. Bond all metal boxes with a pigtail long enough to connect to the ground wires entering th J-Boxes using metal J-Boxes. Laundry- use single Yoke receptacles at J-Boxes provided for the Washer and the Dryer.