Permit: T16CM04800
Permit Details
Apply Date:
06/21/2016
Applicant:
N/A
Description:
(T16DV03180) REMODEL MAIN HOUSE DETACHED GARAGE INTO SLEEPING QTRS. ON R1.
Contractors:
- DANO S TILE INSTALLERS L L C
- EDWARD S HEATING AND COOLING L L C
- ENERGY SOURCE ELECTRIC**APA**
- TAMAYO AND SONS PLUMBING L L C
Outstanding Activity Conditions
Permit Number - T16CM04800
Permit Status: Final
Permit Description: (T16DV03180) REMODEL MAIN HOUSE
DETACHED GARAGE INTO SLEEPING QTRS. ON R1.
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 06/21/2016 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: Final
Permit Number: T16CM04800
Permit Description: (T16DV03180) REMODEL MAIN HOUSE
DETACHED GARAGE INTO SLEEPING QTRS. ON R1.
Total Completed Inspections - 17
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/24/2016 | U VALUE FOR WINDOW | BSTEVENS | Approved | WINDOWS IN GARAGE CONVERSION ARE APPROVED. |
| 08/24/2016 | ELECTRIC - UNDERGROUND | BSTEVENS | Approved | EXPOSE ELECTRIC UNDERGROUND |
| 08/24/2016 | MECHANICAL - FINAL | BSTEVENS | Approved | |
| 08/24/2016 | MECHANICAL - INTERMEDIATE | BSTEVENS | Approved | |
| 08/24/2016 | PLUMBING - FINAL | BSTEVENS | Approved | |
| 08/24/2016 | ELECTRIC - FINAL | BSTEVENS | Approved | |
| 08/24/2016 | ELECTRIC - INTERMEDIATE | BSTEVENS | Approved | |
| 09/08/2016 | ROOF NAILING | BSTEVENS | Approved | 1. ROOF WAS COVERED WITHOUT INSPECTION. 2. WALL SUPPORTING SOUTH END OF OLD JOISTS IS NOW BEARING. THEREFORE, IT WILL REQUIRE A FOOTING AND DOUBLE TOP PLATE AS WELL AS HEADERS AT DOOR OPENINGS. |
| 09/08/2016 | EXT METAL CLIPS/EXT SHEATHING | BSTEVENS | Approved | 1. ROOF WAS COVERED WITHOUT INSPECTION. 2. WALL SUPPORTING SOUTH END OF OLD JOISTS IS NOW BEARING. THEREFORE, IT WILL REQUIRE A FOOTING AND DOUBLE TOP PLATE AS WELL AS HEADERS AT DOOR OPENINGS. |
| 10/06/2016 | BUILDING - PROGRESS | BRUCE_S | Approved | FRONT HOUSE, WORK THAT IS ONGOING: PAINTING - NO PERMIT REQUIRED CHANGED WINDOWS - NO PERMIT REQUIRED TILE FLOORING - NO PERMIT REQUIRED NEW WATER HEATER - COVERED UNDER EXISTING REMODEL PERMIT. REMOVE WINDOW ADJACENT TO FRONT DOOR AND INFILL WALL - COVERED UNDER EXISTING REMODEL PERMIT. MINOR REMODEL OF BATHROOMS - COVERED UNDER EXISTING REMODEL PERMIT. REAR SLEEPING QUARTERS: NO WORK HAS BEEN DONE IN THIS BUILDING SINCE MY INITIAL INSPECTION OF THIS SITE ON 08/24/2016. IT IS CURRENTLY BEING USED TO STORE MATERIALS FOR THE JOB. |
| 12/19/2016 | BUILDING - FINAL | BSTEVENS | Approved | FRONT HOUSE: INSTALL DISHWASHER SEAL DRYWALL AROUND WATER HEATER FLUE PIPE. |
| 12/19/2016 | FRAMING | BSTEVENS | Approved | 1. HEADERS IN BEARING WALLS MUST BE DOUBLE 2X6 MIN. 2. ADD FOOTINGS AT 2X6 BEARING WALLS. 3. CAMERA UNDERGROUND PLUMBING WITH INSPECTOR PRESENT. PROVIDE TEST ON DWV SYSTEM. 4. EXPOSE UNDERGROUND PLUMBING OUTSIDE OF BUILDING. 5. RE-NAIL ROOF PLYWOOD IN ADDITION. |
| 12/23/2016 | PLUMBING - ROUGH, SOIL | BSTEVENS | Approved | |
| 12/23/2016 | PLUMBING - INTERMEDIATE | BSTEVENS | Approved | |
| 12/30/2016 | BUILDING PRE-SLAB | BSTEVENS | Approved | 5202 |
| 12/30/2016 | EXCAVATION/LAYOUT REBAR & ZON | BSTEVENS | Approved | |
| 04/20/2017 | STUCCO MESH | BSTEVENS | Approved |