Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit: T15CM01732
Permit Details
Status:
C of o
Type:
COMMERCIAL NEW
Address:
450 W PASEO REDONDO 02
Address NEW:
450 W PASEO REDONDO 02
Apply Date:
03/16/2015
Applicant:
METRO TUCSON EXPEDITING & DEVELOPMENT
Description:
OFFICE BUILDING
Architects:
- CDG ARCHITECTS
Contractors:
- B F L CONSTRUCTION CO INC ,
Permit Reviews
Permit Number - T15CM01732
Permit Status: C of o
Permit Description: OFFICE BUILDING
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 03/16/2015 | PLANS OK TO SUBMIT - COMM | 03/17/2015 | COMPLETED |
| 03/17/2015 | COMMERCIAL - NEW | 04/28/2015 | COMPLETED |
| 04/28/2015 | COMMERCIAL - NEW | 06/01/2015 | COMPLETED |
| 06/01/2015 | RESUBMITTAL | 06/04/2015 | COMPLETED |
| 06/04/2015 | RESUBMITTAL | 06/04/2015 | COMPLETED |
| 06/04/2015 | RESUBMITTAL | 06/08/2015 | COMPLETED |
| 08/28/2015 | REVISION - - 1ST | 08/28/2015 | COMPLETED |
| 08/28/2015 | REVISION - - 1ST | 09/18/2015 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T15CM01732
Permit Status: C of o
Permit Description: OFFICE BUILDING
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 03/16/2015 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: C of o
Permit Number: T15CM01732
Permit Description: OFFICE BUILDING
Total Completed Inspections - 47
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 04/23/2015 | ZONING - FINAL | jgreen | Approved | Prior to building final or CoO the recordation information for all easements as shown on Sheet 4 (specifically the 15-foot public utility easement, 10-foot public utility easement, and the 15-foot x 15-foot public utility easement) is required to be provided to the ZON or ENG reviewer. Do not remove this P2F until it has been approved. |
| 07/27/2015 | STEM WALL/RETAINING WALL | AQUIROZ | Approved | IVRS - Inspection :* |
| 08/05/2015 | PLUMBING - ROUGH, SOIL | AQUIROZ | Approved | IVRS - Inspection :* |
| 08/11/2015 | ELECTRIC - UFER | AQUIROZ | Approved | IVRS - Inspection :* |
| 11/10/2015 | ELECTRIC - UNDERGROUND | AQUIROZ | Approved | IVRS - Inspection :* |
| 11/13/2015 | ROOF NAILING | AQUIROZ | Approved | IVRS - Inspection :* |
| 11/19/2015 | SITE - SEWER | AQUIROZ | Approved | IVRS - Inspection :* |
| 11/20/2015 | FIRE SPKLR - UG, PIPING, HYDRO | CBASALDUA | Approved | 1. Partial for roughly 80 ft. of C-900 piping. Ok to bury. Still need to hydro and flush. 2. Contractor needs to pull separate Underground Permit. |
| 11/23/2015 | EXT METAL CLIPS/EXT SHEATHING | AQUIROZ | Approved | IVRS - Inspection :* |
| 11/25/2015 | FIRE SPKLR - OH PIPING & HYDRO | CBASALDUA | Approved | |
| 11/30/2015 | REINFORCED MASONRY PRE-GROUT | AQUIROZ | Approved | IVRS - Inspection :* |
| 12/01/2015 | FIRE SPKLR - UG PIPING FLUSH | CBASALDUA | Approved | |
| 12/02/2015 | MECHANICAL - INTERMEDIATE | AQUIROZ | Approved | IVRS - Inspection :* |
| 12/02/2015 | PLUMBING - YARD WTR LINE/TEST | AQUIROZ | Approved | IVRS - Inspection :* |
| 12/03/2015 | EXCAVATION/LAYOUT REBAR & ZON | AQUIROZ | Approved | TRASH ENCLOSURE |
| 12/03/2015 | BUILDING PRE-SLAB | AQUIROZ | Approved | IVRS - Inspection :* |
| 12/04/2015 | PLUMBING - INTERMEDIATE | AQUIROZ | Approved | IVRS - Inspection :* |
| 12/09/2015 | ELECTRIC - INTERMEDIATE | AQUIROZ | Approved | IVRS - Inspection :* |
| 12/09/2015 | FRAMING | AQUIROZ | Approved | IVRS - Inspection :* |
| 12/11/2015 | PLUMBING - ABOVE CEILING | AQUIROZ | Approved | IVRS - Inspection :* |
| 12/11/2015 | U VALUE FOR WINDOW | AQUIROZ | Approved | IVRS - Inspection :* |
| 12/18/2015 | MECHANICAL - ABOVE CEILING | AQUIROZ | Approved | IVRS - Inspection :* |
| 12/18/2015 | BUILDING ABOVE CEILING | AQUIROZ | Approved | IVRS - Inspection :* |
| 12/22/2015 | ELECTRIC - ABOVE CEILING | AQUIROZ | Approved | PROGRESSS ON 2ND FLOOR CORRIDOR |
| 12/31/2015 | SHEET ROCK NAILING | AQUIROZ | Approved | IVRS - Inspection :* |
| 12/31/2015 | STUCCO MESH | AQUIROZ | Approved | IVRS - Inspection :* |
| 01/06/2016 | ELECTRIC - CONSTRUCTION POWER | AQUIROZ | Approved | IVRS - Inspection :* |
| 01/29/2016 | TEP CLEARANCE - AM | AQUIROZ | Approved | TEC |
| 01/29/2016 | PLUMBING - PROGRESS | AQUIROZ | Approved | IVRS - Inspection :* |
| 02/18/2016 | ELECTRIC - PROGRESS | AQUIROZ | Approved | IVRS - Inspection :* |
| 03/10/2016 | FIRE - FINAL | CBASALDUA | Approved | 1. Ok for TCO. 2. All fire systems tested ok. 3. Waiting for elevator to be installed and to test recall before final C of O. |
| 03/10/2016 | FIRE - ALARM FINAL | CBASALDUA | Approved | |
| 03/10/2016 | FIRE SPKLR - FINAL | CBASALDUA | Approved | |
| 03/14/2016 | RIGHT OF WAY - FINAL | DROBERTSON | Approved | |
| 03/14/2016 | PLUMBING - FINAL | aquiroz | Approved | |
| 03/14/2016 | MECHANICAL - FINAL | aquiroz | Approved | |
| 03/14/2016 | MECHANICAL - HOODS | aquiroz | Approved | |
| 03/14/2016 | ELECTRIC - OUTDOOR LIGHTING | aquiroz | Approved | |
| 03/14/2016 | BUILDING - PROGRESS | aquiroz | Approved | |
| 03/17/2016 | NPPO - FINAL | MRUSSO1 | Approved | |
| 03/17/2016 | OUTDOOR LIGHTING FINAL | aquiroz | Approved | |
| 03/17/2016 | ELECTRIC - FINAL | aquiroz | Approved | |
| 03/17/2016 | FIREWALL/FIREBARRIER/FIRESTOP | aquiroz | Approved | |
| 04/12/2016 | SIGN - FINAL | MRUSSO | Approved | |
| 04/12/2016 | LANDSCAPE - FINAL | MRUSSO | Approved | |
| 04/13/2016 | ENGINEERING - FINAL | RB | Approved | PER AQUIROZ/MRUSSO |
| 04/13/2016 | BUILDING - FINAL | RB | Approved | PER AQUIROZ |