Permit: T14CM03855
Permit Details
Apply Date:
06/20/2014
Applicant:
METRO TUCSON EXPEDITING & DEVELOPMENT
Description:
TI: REMODEL/FACADE - APARTMENTS
Architects:
- GOLDSTEIN GENE
Contractors:
- ADVANCED RENOVATIONS L L C
Permit Reviews
Permit Number - T14CM03855
Permit Status: Expired
Permit Description: TI: REMODEL/FACADE - APARTMENTS
Start Date | Submittal | Complete Date | Status |
---|---|---|---|
06/20/2014 | COMMERCIAL - TI | 06/25/2014 | COMPLETED |
06/25/2014 | WALK THRU - COMM | 06/27/2014 | COMPLETED |
06/27/2014 | OTHER | 08/20/2014 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T14CM03855
Permit Status: Expired
Permit Description: TI: REMODEL/FACADE - APARTMENTS
Total Outstanding Activity Conditions - 1
Date | Name |
---|---|
06/20/2014 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Outstanding Inspections
Permit Status: Expired
Permit Number: T14CM03855
Permite Description: TI: REMODEL/FACADE - APARTMENTS
Total Outstanding Inspections - 2
Last Inspection Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
12/03/2014 | ELECTRIC - FINAL | N/A | Not ready for Inspection | EXPOSED WIRES THRU-OUT. OPEN ALL PANELS, PROVIDE ACCESS, & COMPLETE PANEL SCHEDULE. INCOMPLETE INSPECTION |
12/03/2014 | ELECTRIC - FINAL | N/A | Not ready for Inspection | IVRS - Inspection :* |
Completed Inspections
Permit Status: Expired
Permit Number: T14CM03855
Permit Description: TI: REMODEL/FACADE - APARTMENTS
Total Completed Inspections - 14
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
09/09/2014 | ELECTRIC - ABOVE CEILING | MPUGH | Approved | IVRS - Inspection :* |
09/09/2014 | ELECTRIC - INTERMEDIATE | MPUGH | Approved | IVRS - Inspection :* |
09/17/2014 | SHEET ROCK NAILING | MPUGH | Approved | IVRS - Inspection :* |
09/24/2014 | TEP CLEARANCE - AM | MPUGH | Approved | INCR |
11/07/2014 | FRAMING | MPUGH | Approved | IVRS - Inspection :* |
12/03/2014 | BUILDING - FINAL | MPUGH | Approved | COMPLETE SHOP, COMPLETE POOL ENCLOSURE. INCOMPLETE INSPECTION |
12/03/2014 | MECHANICAL - FINAL | MPUGH | Approved | IVRS - Inspection :* |
12/03/2014 | MECHANICAL - INTERMEDIATE | MPUGH | Approved | IVRS - Inspection :* |
12/03/2014 | BUILDING - FINAL | MPUGH | Approved | IVRS - Inspection :* |
12/03/2014 | BUILDING ABOVE CEILING | MPUGH | Approved | IVRS - Inspection :* |
12/03/2014 | ROOF NAILING | MPUGH | Approved | IVRS - Inspection :* |
12/03/2014 | REINFORCED MASONRY PRE-GROUT | MPUGH | Approved | IVRS - Inspection :* |
12/03/2014 | EXCAVATION/LAYOUT REBAR & ZON | MPUGH | Approved | IVRS - Inspection :* |
12/03/2014 | FIRE - FINAL | CSCHULTZ | Approved | 1. On pg A 1.0 of the approved plans the exercise room egress door # 42 has a access-controlled mag lock system this device was not indicated on the approved plans and will need to meet sections IFC 1008.1.9.8 and 1008.1.9.9 2. All doors exiting into the pool area from the lounge shall be self-closing, self -latching type only and need to meet IFC section 1008.1.9.2 exception - you can install an approved fencing before the pool and not need to change locks on doors. 3. All egress gates exiting from pool area shall meet IFC sections 1008.1.9.3 and 1008.1.9.2, gate locks cannot be double cylinder keyed dead bolt locks must be type that can be opened without the use of a key or any special knowledge or effort 4. Need two fire extinguishers 2A-10BC type one for the lounge area and other in the office area |