Permit Details

Status:
Expired
Type:
COMMERCIAL OTHER
Address:
160 S SCOTT AV
Address NEW:
160 S SCOTT AV
Apply Date:
05/01/2014
Applicant:
N/A
Description:
REMODEL KITCHEN;COMM R1:COVERSHEET CHANGES
Architects:
  • CATALANO, VINCENT VICTOR
Contractors:
  • CALDWELL CONSTRUCTION L L C *C*

Permit Reviews

Permit Number - T14CM02524
Permit Status: Expired
Permit Description: REMODEL KITCHEN;COMM R1:COVERSHEET CHANGES
Start Date Submittal Complete Date Status  
05/01/2014 COMMERCIAL - TI 08/27/2014 COMPLETED Review Details
08/27/2014 REVISION - - 1ST 09/05/2014 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T14CM02524
Permit Status: Expired
Permit Description: REMODEL KITCHEN;COMM R1:COVERSHEET CHANGES
Total Outstanding Activity Conditions - 3
Date Name
05/01/2014 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.
05/08/2014 SPECIAL INSPECTION FOR FIELD WELDING IS REQUIRED.
05/08/2014 SPECIAL INSPECTION FOR EPOXY ANCHORS IS REQUIRED.

Outstanding Inspections

Permit Status: Expired
Permit Number: T14CM02524
Permite Description: REMODEL KITCHEN;COMM R1:COVERSHEET CHANGES
Total Outstanding Inspections - 3
Last Inspection Date Description Inspector Results Comments
MECHANICAL - FINAL N/A Not Inspected
08/26/2014 BUILDING - FINAL N/A Partial Approval 1.PENDING FIRE FINAL UNRELATED TO KITCHEN OK FOR USE
08/26/2014 BUILDING - FINAL N/A Partial Approval IVRS - Inspection :*

Completed Inspections

Permit Status: Expired
Permit Number: T14CM02524
Permit Description: REMODEL KITCHEN;COMM R1:COVERSHEET CHANGES
Total Completed Inspections - 19
Date Description Inspector Results Comments
07/30/2014 PLUMBING - ROUGH, SOIL MRAMBER Approved IVRS - Inspection :*
08/06/2014 PLUMBING - INTERMEDIATE MRAMBER Approved IVRS - Inspection :*
08/06/2014 ELECTRIC - INTERMEDIATE MRAMBER Approved IVRS - Inspection :*
08/06/2014 FRAMING MRAMBER Approved IVRS - Inspection :*
08/20/2014 PLUMBING - GAS PRESSURE TEST MRAMBER Approved IVRS - Inspection :*
08/21/2014 MECHANICAL - INTERMEDIATE MRAMBER Approved IVRS - Inspection :*
08/21/2014 BUILDING ABOVE CEILING MRAMBER Approved IVRS - Inspection :*
08/22/2014 ELECTRIC - PROGRESS MRAMBER Approved IVRS - Inspection :*
08/25/2014 FIRE - KITCHEN EXH HOOD FINAL CSCHULTZ Approved
08/25/2014 FIRE SPKLR - FINAL CSCHULTZ Approved
08/25/2014 MECHANICAL - PROGRESS MRAMBER Approved IVRS - Inspection :*
08/25/2014 MECHANICAL - HOOD SYSTEMS MRAMBER Approved IVRS - Inspection :*
08/25/2014 MECHANICAL - HOODS MRAMBER Approved IVRS - Inspection :*
08/25/2014 PLUMBING - FINAL MRAMBER Approved IVRS - Inspection :*
08/25/2014 PLUMBING - PROGRESS MRAMBER Approved IVRS - Inspection :*
08/25/2014 PLUMBING - GAS PRESS TEST FNL MRAMBER Approved IVRS - Inspection :*
08/25/2014 ELECTRIC - FINAL MRAMBER Approved IVRS - Inspection :*
08/25/2014 BUILDING - PROGRESS MRAMBER Approved IVRS - Inspection :*
09/04/2014 FIRE - FINAL KenB Approved Arrangements will occur between TFD and owner's to address Vertical enclosure requirements from Chapter 11 of the 2012 IFC.

Documents

File Name Document Type  
001_C1.TIF CONSTRPLANS VIEW
002_P2.TIF CONSTRPLANS VIEW
003_P4.TIF CONSTRPLANS VIEW
004_A1.TIF CONSTRPLANS VIEW
005_A2.TIF CONSTRPLANS VIEW
006_S1.0.TIF CONSTRPLANS VIEW
007_S2.0.TIF CONSTRPLANS VIEW
008_M1.TIF CONSTRPLANS VIEW
009_M2.TIF CONSTRPLANS VIEW
010_P1.TIF CONSTRPLANS VIEW
011_P2.TIF CONSTRPLANS VIEW
012_P3.TIF CONSTRPLANS VIEW
013_P4.TIF CONSTRPLANS VIEW
014_E0.0.TIF CONSTRPLANS VIEW
015_ED1.0.TIF CONSTRPLANS VIEW
016_E1.0.TIF CONSTRPLANS VIEW
017_FS-1.TIF CONSTRPLANS VIEW
018_FS-2.TIF CONSTRPLANS VIEW
019_FS-3.TIF CONSTRPLANS VIEW
020_FS-4.TIF CONSTRPLANS VIEW
None DOCUMENTS VIEW