Permit: T13CM02593
Permit Details
Apply Date:
04/30/2013
Applicant:
BWS ARCHITECTS
Description:
NEW MEDICAL OFFICE TCO FOR PHASE 1
Contractors:
- B F L CONSTRUCTION CO INC ,
Permit Reviews
Permit Number - T13CM02593
Permit Status: C of o
Permit Description: NEW MEDICAL OFFICE
TCO FOR PHASE 1
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 01/30/2014 | REVISION - - 2ND | 02/03/2014 | COMPLETED |
| 02/03/2014 | REVISION - - 3RD | 02/03/2014 | COMPLETED |
| 02/03/2014 | REVISION - - 4TH | 03/18/2014 | COMPLETED |
| 03/18/2014 | REVISION - - 5TH | 03/18/2014 | COMPLETED |
| 04/30/2013 | PLANS OK TO SUBMIT - COMM | 04/30/2013 | COMPLETED |
| 04/30/2013 | COMMERCIAL - NEW | 06/06/2013 | COMPLETED |
| 06/14/2013 | RESUBMITTAL | 07/09/2013 | COMPLETED |
| 07/09/2013 | RESUBMITTAL | 07/16/2013 | COMPLETED |
| 08/29/2013 | REVISION - - 1ST | 08/29/2013 | COMPLETED |
| 08/29/2013 | REVISION - - 1ST | 09/09/2013 | COMPLETED |
| 09/09/2013 | REVISION - - 1ST | 09/12/2013 | COMPLETED |
Completed Inspections
Permit Status: C of o
Permit Number: T13CM02593
Permit Description: NEW MEDICAL OFFICE
TCO FOR PHASE 1
Total Completed Inspections - 54
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/06/2013 | SITE - SEWER | RMYERS | Approved | 1. 6" SCH 40 PVC DWV temporary sewer installed at upper end and connected to existing. Extended downstream to re-connection with existing sewer. OK to cover. |
| 08/21/2013 | ENGINEERING - FINAL | RLEDONNE | Approved | GOT WITH GRADING CONTRACTOR ABOUT 18" HDPE PIPING WORKING BACK FROM BUBBLER . |
| 09/06/2013 | PLUMBING - YARD WTR LINE/TEST | RMYERS | Approved | 1. RP at meter installed. |
| 09/30/2013 | MECHANICAL - UNDERGROUND | RMYERS | Approved | |
| 10/23/2013 | PLUMBING - ROOF DRAINS | RMYERS | Approved | 1. Underground storm drain complete. Tied into manhole OK. OK to cover Water test OK. |
| 10/23/2013 | PLUMBING - ROUGH, SOIL | RMYERS | Approved | 1. Underground storm water drains water test OK. OK to cover. |
| 10/23/2013 | PLUMBING - ROUGH, SOIL | RMYERS | Approved | 1. Solvent weld storm drain complete underground OK. Subject to water test. |
| 10/29/2013 | PLUMBING - PRE SLAB | RMYERS | Approved | IVRS - Inspection :* |
| 10/29/2013 | BUILDING PRE-SLAB | RMYERS | Approved | IVRS - Inspection :* |
| 10/29/2013 | BUILDING PRE-SLAB | RMYERS | Approved | |
| 12/10/2013 | REINFORCED MASONRY PRE-GROUT | RMYERS | Approved | 1. Last lift at elevator shaft to top of beam OK |
| 12/10/2013 | EXCAVATION/LAYOUT REBAR & ZON | RMYERS | Approved | 1, Infill at column pads OK. |
| 12/16/2013 | FIRE SPKLR - UG PIPING FLUSH | CSCHULTZ | Approved | 2 mins. 30 secs. flushed - APPROVED |
| 12/16/2013 | FIRE SPKLR - UG, PIPING, HYDRO | CSCHULTZ | Approved | 200 PSI for 2 hours - APPROVED 2mins 30 secs. Flushed - APPROVED |
| 03/06/2014 | ROOF NAILING | RMYERS | Approved | |
| 03/28/2014 | ELECTRIC - SERVICE UPGRADE | RMYERS | Approved | |
| 03/28/2014 | ELECTRIC - TEMPORARY SERVICE | RMYERS | Approved | |
| 04/02/2014 | EXT METAL CLIPS/EXT SHEATHING | RMYERS | Approved | |
| 04/02/2014 | STUCCO MESH | RMYERS | Approved | |
| 04/02/2014 | FIREWALL/FIREBARRIER/FIRESTOP | RMYERS | Approved | |
| 04/11/2014 | PLUMBING - INTERMEDIATE | RMYERS | Approved | |
| 04/11/2014 | SEWER - PRE CONSTRUCTION MTG | RMYERS | Approved | |
| 04/11/2014 | FRAMING | RMYERS | Approved | |
| 04/18/2014 | SHEET ROCK NAILING | RMYERS | Approved | |
| 04/21/2014 | ELECTRIC - INTERMEDIATE | RMYERS | Approved | |
| 04/23/2014 | MECHANICAL - INTERMEDIATE | RMYERS | Approved | |
| 05/01/2014 | PLUMBING - PROGRESS | RMYERS | Approved | |
| 05/30/2014 | MECHANICAL - ABOVE CEILING | RMYERS | Approved | |
| 05/30/2014 | ELECTRIC - ABOVE CEILING | RMYERS | Approved | |
| 05/30/2014 | PLUMBING - ABOVE CEILING | RMYERS | Approved | |
| 05/30/2014 | BUILDING ABOVE CEILING | RMYERS | Approved | |
| 06/05/2014 | ELECTRIC - UFER | AQUIROZ | Approved | IVRS - Inspection :* |
| 06/06/2014 | TEP CLEARANCE - AM | aquiroz | Approved | TEC |
| 06/19/2014 | STEM WALL/RETAINING WALL | AQUIROZ | Approved | IVRS - Inspection :* |
| 07/03/2014 | FIRE SPKLR - OH PIPING & HYDRO | wmotto | Approved | |
| 07/10/2014 | RIGHT OF WAY - FINAL | TWOLFGAN | Approved | |
| 07/11/2014 | NPPO - FINAL | RLEDONNE | Approved | |
| 07/11/2014 | SIGN - FINAL | RLEDONNE | Approved | |
| 07/11/2014 | LANDSCAPE - FINAL | RLEDONNE | Approved | COMPLET ALLWORK ON PHASE #1. |
| 07/11/2014 | ELECTRIC - FINAL | AQUIROZ | Approved | IVRS - Inspection :* |
| 07/11/2014 | U VALUE FOR WINDOW | AQUIROZ | Approved | IVRS - Inspection :* |
| 07/14/2014 | FIRE SPKLR - FINAL | KRB | Approved | |
| 07/14/2014 | FIRE - ALARM FINAL | KRB | Approved | |
| 07/17/2014 | PLUMBING - FINAL | AQUIROZ | Approved | IVRS - Inspection :* |
| 07/17/2014 | BUILDING - FINAL | AQUIROZ | Approved | IVRS - Inspection :* |
| 07/29/2014 | FIRE - FINAL | WMOTTO | Approved | |
| 07/29/2014 | FIRE - KITCHEN EXH HOOD FINAL | WMOTTO | Approved | |
| 08/05/2014 | MECHANICAL - FINAL | AQUIROZ | Approved | IVRS - Inspection :* |
| 08/05/2014 | MECHANICAL - HOODS | AQUIROZ | Approved | IVRS - Inspection :* |
| 11/19/2014 | ELECTRIC - OUTDOOR LIGHTING | AQUIROZ | Approved | IVRS - Inspection :* |
| 12/22/2014 | ELECTRIC - UNDERGROUND | AQUIROZ | Approved | IVRS - Inspection :* |
| 12/22/2014 | BUILDING - PROGRESS | AQUIROZ | Approved | IVRS - Inspection :* |
| 01/06/2015 | OUTDOOR LIGHTING FINAL | AQUIROZ | Approved | IVRS - Inspection :* |
| 04/10/2015 | MECHANICAL - HYDRONIC PIPING | aquiroz | Approved | per final |