Permit: T13CM02209
Permit Details
Apply Date:
04/15/2013
Applicant:
METRO TUCSON EXPEDITING & DEVELOPMENT
Description:
TI: GROCERY STORE
Architects:
- DANIEL MACIAS
Contractors:
- HAUGEBAK CONSTRUCTION COMPANY ,
Permit Reviews
Permit Number - T13CM02209
Permit Status: Expired
Permit Description: TI: GROCERY STORE
Start Date | Submittal | Complete Date | Status |
---|---|---|---|
04/15/2013 | COMMERCIAL - TI | 05/07/2013 | COMPLETED |
05/07/2013 | COMMERCIAL - TI | 06/11/2013 | COMPLETED |
06/11/2013 | COMMERCIAL - TI | 07/10/2013 | COMPLETED |
07/10/2013 | COMMERCIAL - TI | 07/25/2013 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T13CM02209
Permit Status: Expired
Permit Description: TI: GROCERY STORE
Total Outstanding Activity Conditions - 4
Date | Name |
---|---|
04/15/2013 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
05/16/2013 | SPECIAL INSPECTION FOR FIELD WELDING IS REQUIRED. |
05/16/2013 | SPECIAL INSPECTION FOR EPOXY ANCHORS IS REQUIRED. |
05/16/2013 | SPECIAL INSPECTION FOR EXPANSION ANCHORS IS REQUIRED. |
Outstanding Inspections
Permit Status: Expired
Permit Number: T13CM02209
Permite Description: TI: GROCERY STORE
Total Outstanding Inspections - 15
Last Inspection Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
BUILDING - PROGRESS | N/A | Not Inspected | ||
PLUMBING - PRE SLAB | N/A | Not Inspected | ||
PLUMBING - ABOVE CEILING | N/A | Not Inspected | ||
PLUMBING - PROGRESS | N/A | Not Inspected | ||
PLUMBING - FINAL | N/A | Not Inspected | ||
MECHANICAL - ABOVE CEILING | N/A | Not Inspected | ||
FIRE SPKLR - FINAL | N/A | Not Inspected | ||
08/29/2013 | SHEET ROCK NAILING | N/A | Partial Approval | ACCOUNTING ROOM - OK TO TAPE PROGRESS AREA |
08/29/2013 | SHEET ROCK NAILING | N/A | Partial Approval | IVRS - Inspection :* |
09/19/2013 | FRAMING | N/A | Partial Approval | IVRS - Inspection :* |
09/19/2013 | FRAMING | N/A | Partial Approval | PRODUCE PREP - ALL OK: 1035, 2035, & 3035 |
09/19/2013 | PLUMBING - INTERMEDIATE | N/A | Partial Approval | IVRS - Inspection :* |
10/17/2013 | ELECTRIC - INTERMEDIATE | N/A | Denied | 1. LIGHTING INSTALLED AT CUSTOMER SERVICE OK 2. EXISTING LOW VOLTAGE & LIGHTING WHIPS & EMT TO BE REMOVED OR STRAPPED OFF GRID CEILING & ACCOUNTING ROOM 3. LIQUOR DEPARTMENT LIGHTING WHIPS & HOMERUN TO BE OFF GRID. J. BOX TO BE CLOSED UP & BEER COOLER TO BE CLEANED ON TOP 4. REDUCE AREA 1/2 K.O SEAL MISSING 5.BAKERY ARE3A LOW VOLTAGE TO BE OFF GRID 6. EXIT TO BE REMOUNTED BREAD AREA 7. LOW VOLTAGE & LLIGHTING WHIPS TO BE OFF GRID MEAT DEPARTMENT 8. SEAFOOD AREA OPEN J. BOXES & MC TO BE STRAPPED & OFF GRID 9. REFRIGERATION MC & J. BOXES TO BE STRAPPED AT CASES 10. DAIRY J. BOX OPEN. MC & LOW VOLTAGE TO BE STRAPPED 11. PHARMACY FLEX & LOW VOLTAGE TO BE OFF GRID 12. FRONT END 3/4 EMT & LOW COLTAGE TO BE STRAPPED & OFF GRID 13. PANELS AT BACKROOM. SPARES TO BE PLACED GOING INTO WALL & DOWN TO LIVE PANELS & WALL TO BE PATCHED 14. U.S CAN REGISTER 4 OPEN BOXES & LOW VOLTAGE TO BE OFF GRID 15. COVER MISSING FOR POWER STRIP 16. FRONT ENTRANCE STRIP LIGHTING 1/2 PLUG MISSING & BROKEN COVER |
10/17/2013 | ELECTRIC - INTERMEDIATE | N/A | Denied | IVRS - Inspection : See detailed listing on site.| 999* |
10/17/2013 | ELECTRIC - ABOVE CEILING | N/A | Denied | IVRS - Inspection : See detailed listing on site.| 999* |
Completed Inspections
Permit Status: Expired
Permit Number: T13CM02209
Permit Description: TI: GROCERY STORE
Total Completed Inspections - 4
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
09/12/2013 | PLUMBING - ROUGH, SOIL | RMORENO | Approved | IVRS - Inspection :* |
09/24/2013 | BUILDING ABOVE CEILING | RMORENO | Approved | IVRS - Inspection :* |
01/24/2014 | ELECTRIC - FINAL | RMORENO | Approved | IVRS - Inspection :* |
01/24/2014 | BUILDING - FINAL | RMORENO | Approved | IVRS - Inspection :* |