Inspection History Details
Inspection Status: Denied
Inspection History: ELECTRIC - INTERMEDIATE
Permit Number - T13CM02209
Inspection Description - ELECTRIC - INTERMEDIATE
Inspection Status - Denied
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
10/17/2013 | ELECTRIC - INTERMEDIATE | Denied | IVRS - Inspection : See detailed listing on site.| 999* |
|
10/17/2013 | ELECTRIC - INTERMEDIATE | Denied | 1. LIGHTING INSTALLED AT CUSTOMER SERVICE OK 2. EXISTING LOW VOLTAGE & LIGHTING WHIPS & EMT TO BE REMOVED OR STRAPPED OFF GRID CEILING & ACCOUNTING ROOM 3. LIQUOR DEPARTMENT LIGHTING WHIPS & HOMERUN TO BE OFF GRID. J. BOX TO BE CLOSED UP & BEER COOLER TO BE CLEANED ON TOP 4. REDUCE AREA 1/2 K.O SEAL MISSING 5.BAKERY ARE3A LOW VOLTAGE TO BE OFF GRID 6. EXIT TO BE REMOUNTED BREAD AREA 7. LOW VOLTAGE & LLIGHTING WHIPS TO BE OFF GRID MEAT DEPARTMENT 8. SEAFOOD AREA OPEN J. BOXES & MC TO BE STRAPPED & OFF GRID 9. REFRIGERATION MC & J. BOXES TO BE STRAPPED AT CASES 10. DAIRY J. BOX OPEN. MC & LOW VOLTAGE TO BE STRAPPED 11. PHARMACY FLEX & LOW VOLTAGE TO BE OFF GRID 12. FRONT END 3/4 EMT & LOW COLTAGE TO BE STRAPPED & OFF GRID 13. PANELS AT BACKROOM. SPARES TO BE PLACED GOING INTO WALL & DOWN TO LIVE PANELS & WALL TO BE PATCHED 14. U.S CAN REGISTER 4 OPEN BOXES & LOW VOLTAGE TO BE OFF GRID 15. COVER MISSING FOR POWER STRIP 16. FRONT ENTRANCE STRIP LIGHTING 1/2 PLUG MISSING & BROKEN COVER |
|
10/10/2013 | ELECTRIC - INTERMEDIATE | Denied | IVRS - Inspection : See detailed listing on site.| 999* |
|
10/10/2013 | ELECTRIC - INTERMEDIATE | Denied | 1. COMMERCIAL KITCHEN OR PREP AREA TO BE GFI 2. IN CEILING J. BOX OPEN & K.O. SEAL MISSING 3. INDUSTRIAL COVERS TO HAVE 3 SCREWS 4. A/C SPLIT UNIT IN OFFICE OK - ROOF OK TOO |
|
09/24/2013 | ELECTRIC - INTERMEDIATE | Denied | IVRS - Inspection : See detailed listing on site.| 999* |
|
09/24/2013 | ELECTRIC - INTERMEDIATE | Denied | 1. CUSTOMER SERVICE MC TO BE STRAPPED & ABOVE CEILING - STILL TO BE INSPECTED 2. PRODUCE PREP TEE BAR - CEILING OK 3. ELECTRIC ABOVE CEILING AT PRODUCE PREP NOT READY |
|
09/19/2013 | ELECTRIC - INTERMEDIATE | Partial Approval | IVRS - Inspection :* | |
09/12/2013 | ELECTRIC - INTERMEDIATE | Partial Approval | IVRS - Inspection :* | |
09/12/2013 | ELECTRIC - INTERMEDIATE | Partial Approval | 1. ACCOUNTING ROOM OK 2. PRODUCE PREP ROOM ROUGH PLUMBING OK 3. STILL TO INSPECT ROOF A/C |
|
08/29/2013 | ELECTRIC - INTERMEDIATE | Partial Approval | IVRS - Inspection :* | |
08/29/2013 | ELECTRIC - INTERMEDIATE | Partial Approval | OUTLETS & LIGHTING IN ACCOUNTING ROOM | |
08/21/2013 | ELECTRIC - INTERMEDIATE | Partial Approval | IVRS - Inspection :* | |
08/21/2013 | ELECTRIC - INTERMEDIATE | Partial Approval | NEW PANEL & TRANSFORMER SET IN PLACE | |
08/13/2013 | ELECTRIC - INTERMEDIATE | Partial Approval | IVRS - Inspection :* | |
08/13/2013 | ELECTRIC - INTERMEDIATE | Partial Approval | FLORAL PREP AREA |