Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

PRO is currently experiencing an outage. Some documents and records may not be available on PRO momentarily. We apologize for the inconvenience and are working to restore full access.

Permit Number: T13CM02209
Parcel: 13405119H

Address:
9401 E 22ND ST

Review Status: Completed

Review Details: COMMERCIAL - TI

Permit Number - T13CM02209
Review Name: COMMERCIAL - TI
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
05/08/2013 MARTIN BROWN FIRE REVIEW Approved
05/16/2013 RONALD BROWN BUILDING-COMMERCIAL REVIEW Approved
05/22/2013 ROBERT SHERRY WATER REVIEW Approved
05/22/2013 ROBERT SHERRY PLUMBING-COMMERCIAL REVIEW Denied 1. Verify that the mixing valve specified for fixtures (e.g.PLC-2B) are listed as conforming to ASSE 1070. Reference: Sections 416.4 and 607.1.2, IPC 2012.
2. Revise the drains for the new 3-compartment sink (detail PSD-7/P6.1) to be independently routed to the indirect waste receptor and terminated with an air gap. Reference: Sections 801.2 and 802.1, IPC 2012.
3. Modify detail PSD-1/P6.1 to show that the installation of the open hub drains meets the requirements of Section 802.3.2, IPC 2006 with regard to the minimum projection above the floor (1") and show how the floor is to be made impervious to water at the point of penetration into the floor.
4. Provide accessible cleanouts in the island sink vent system to permit rodding of all portions of the vents located below the flood rim of the fixture. Reference: Section 916.3, IPC 2012.
05/22/2013 ROBERT SHERRY MECHANICAL-COMMERCIAL REVIEW Denied Provide electrical and balancing data for the fan that is to be replaced. Reference: Section 107.2.1, IBC 2012.
05/30/2013 RAY MAJUTA ELECTRICAL-COMMERCIAL REVIEW Approved

Final Status

Task End Date Reviewer's Name Type of Review Description
06/11/2013 FERNE RODRIGUEZ OUT TO CUSTOMER Completed
06/11/2013 CPIERCE1 REJECT SHELF Completed