Permit Details

Status:
Expired
Type:
COMMERCIAL ADDITION
Apply Date:
10/24/2012
Applicant:
METRO TUCSON EXPEDITING & DEVELOPMENT
Description:
ADD; LOADING DOCK TO RESTAURANT AND ENCLOSE PATIO
Contractors:
  • BARKER MORRISSEY CONTRACTING INC **APA**

Permit Reviews

Permit Number - T12CM06790
Permit Status: Expired
Permit Description: ADD; LOADING DOCK TO RESTAURANT AND ENCLOSE PATIO
Start Date Submittal Complete Date Status  
09/03/2013 REVISION - - 1ST 09/04/2013 COMPLETED Review Details
10/24/2012 COMMERCIAL - TI 11/28/2012 COMPLETED Review Details
11/28/2012 COMMERCIAL - TI 02/11/2013 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T12CM06790
Permit Status: Expired
Permit Description: ADD; LOADING DOCK TO RESTAURANT AND ENCLOSE PATIO
Total Outstanding Activity Conditions - 6
Date Name
10/24/2012 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.
10/24/2012 SPECIAL INSPECTION FORMS AND REPORTS REQUIRED PRIOR TO ISSUANCE OF A CERTIFICATE OF OCCUPANCY.
10/24/2012 SPECIAL INSPECTION FOR CONCRETE IS REQUIRED..
10/24/2012 SPECIAL INSPECTION FOR REINFORCING STEEL AND/OR PRE-STRESSING TENDONS IS REQUIRED.
10/24/2012 SPECIAL INSPECTION FOR STRUCTURAL MASONRY IS REQUIRED.
10/24/2012 SPECIAL INSPECTION FOR FOUNDATION/EXCAVATION IS REQUIRED.

Completed Inspections

Permit Status: Expired
Permit Number: T12CM06790
Permit Description: ADD; LOADING DOCK TO RESTAURANT AND ENCLOSE PATIO
Total Completed Inspections - 21
Date Description Inspector Results Comments
02/13/2013 STEM WALL/RETAINING WALL DQUINN Approved IVRS - Inspection :*
02/13/2013 EXCAVATION/LAYOUT REBAR & ZON DQUINN Approved IVRS - Inspection :*
03/04/2013 PLUMBING - ROUGH, SOIL DQUINN Approved IVRS - Inspection :*
03/04/2013 BUILDING PRE-SLAB DQUINN Approved IVRS - Inspection :*
05/17/2013 PLUMBING - FINAL DQUINN Approved IVRS - Inspection :*
05/17/2013 PLUMBING - INTERMEDIATE DQUINN Approved IVRS - Inspection :*
12/03/2013 BUILDING - PROGRESS JMILITEL Approved RELOCATE LIGHT SWITCH IN ATTIC OVER TO CRAWL HOLE. EXTEND SERVICE PLATFORM TO 30" WIDE. HORIZONTAL SECTION OF FURNACE VENT CAN BE NO MORE THAN 75% OF TOTAL VENT HEIGHT. PROVIDE A PROTECTIVE COATING ON EXPOSED ARMFLEX. SEAL FLASHING AT ELEC CONDUIT.
12/03/2013 MECHANICAL - INTERMEDIATE JMILITEL Approved IVRS - Inspection :*
12/03/2013 ELECTRIC - ABOVE CEILING JMILITEL Approved IVRS - Inspection :*
12/03/2013 ELECTRIC - INTERMEDIATE JMILITEL Approved IVRS - Inspection :*
12/03/2013 BUILDING - PROGRESS JMILITEL Approved IVRS - Inspection :*
12/03/2013 U VALUE FOR WINDOW JMILITEL Approved IVRS - Inspection :*
12/03/2013 FRAMING JMILITEL Approved IVRS - Inspection :*
12/03/2013 EXT METAL CLIPS/EXT SHEATHING JMILITEL Approved IVRS - Inspection :*
12/18/2013 BUILDING - FINAL JMILITEL Approved OK TO OCCUPY
12/18/2013 MECHANICAL - FINAL JMILITEL Approved IVRS - Inspection :*
12/18/2013 ELECTRIC - FINAL JMILITEL Approved IVRS - Inspection :*
12/18/2013 BUILDING - FINAL JMILITEL Approved IVRS - Inspection :*
12/18/2013 FIRE - ALARM FINAL CSCHULTZ Approved
12/18/2013 FIRE SPKLR - FINAL CSCHULTZ Approved
12/18/2013 FIRE - FINAL CSCHULTZ Approved

Documents

File Name Document Type  
001_A0.0.TIF CONSTRPLANS VIEW
002_C1.0.TIF CONSTRPLANS VIEW
003_A1.1.TIF CONSTRPLANS VIEW
004_A1.2.TIF CONSTRPLANS VIEW
005_A2.0.TIF CONSTRPLANS VIEW
006_A2.1.TIF CONSTRPLANS VIEW
007_M1.TIF CONSTRPLANS VIEW
008_M2.TIF CONSTRPLANS VIEW
009_E1.0.TIF CONSTRPLANS VIEW
None DOCUMENTS VIEW