Permit: T12CM06790
Permit Details
Apply Date:
10/24/2012
Applicant:
METRO TUCSON EXPEDITING & DEVELOPMENT
Description:
ADD; LOADING DOCK TO RESTAURANT AND ENCLOSE PATIO
Contractors:
- BARKER MORRISSEY CONTRACTING INC **APA**
Permit Reviews
Permit Number - T12CM06790
Permit Status: Expired
Permit Description: ADD; LOADING DOCK TO RESTAURANT AND ENCLOSE PATIO
Start Date | Submittal | Complete Date | Status |
---|---|---|---|
09/03/2013 | REVISION - - 1ST | 09/04/2013 | COMPLETED |
10/24/2012 | COMMERCIAL - TI | 11/28/2012 | COMPLETED |
11/28/2012 | COMMERCIAL - TI | 02/11/2013 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T12CM06790
Permit Status: Expired
Permit Description: ADD; LOADING DOCK TO RESTAURANT AND ENCLOSE PATIO
Total Outstanding Activity Conditions - 6
Date | Name |
---|---|
10/24/2012 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
10/24/2012 | SPECIAL INSPECTION FORMS AND REPORTS REQUIRED PRIOR TO ISSUANCE OF A CERTIFICATE OF OCCUPANCY. |
10/24/2012 | SPECIAL INSPECTION FOR CONCRETE IS REQUIRED.. |
10/24/2012 | SPECIAL INSPECTION FOR REINFORCING STEEL AND/OR PRE-STRESSING TENDONS IS REQUIRED. |
10/24/2012 | SPECIAL INSPECTION FOR STRUCTURAL MASONRY IS REQUIRED. |
10/24/2012 | SPECIAL INSPECTION FOR FOUNDATION/EXCAVATION IS REQUIRED. |
Completed Inspections
Permit Status: Expired
Permit Number: T12CM06790
Permit Description: ADD; LOADING DOCK TO RESTAURANT AND ENCLOSE PATIO
Total Completed Inspections - 21
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
02/13/2013 | STEM WALL/RETAINING WALL | DQUINN | Approved | IVRS - Inspection :* |
02/13/2013 | EXCAVATION/LAYOUT REBAR & ZON | DQUINN | Approved | IVRS - Inspection :* |
03/04/2013 | PLUMBING - ROUGH, SOIL | DQUINN | Approved | IVRS - Inspection :* |
03/04/2013 | BUILDING PRE-SLAB | DQUINN | Approved | IVRS - Inspection :* |
05/17/2013 | PLUMBING - FINAL | DQUINN | Approved | IVRS - Inspection :* |
05/17/2013 | PLUMBING - INTERMEDIATE | DQUINN | Approved | IVRS - Inspection :* |
12/03/2013 | BUILDING - PROGRESS | JMILITEL | Approved | RELOCATE LIGHT SWITCH IN ATTIC OVER TO CRAWL HOLE. EXTEND SERVICE PLATFORM TO 30" WIDE. HORIZONTAL SECTION OF FURNACE VENT CAN BE NO MORE THAN 75% OF TOTAL VENT HEIGHT. PROVIDE A PROTECTIVE COATING ON EXPOSED ARMFLEX. SEAL FLASHING AT ELEC CONDUIT. |
12/03/2013 | MECHANICAL - INTERMEDIATE | JMILITEL | Approved | IVRS - Inspection :* |
12/03/2013 | ELECTRIC - ABOVE CEILING | JMILITEL | Approved | IVRS - Inspection :* |
12/03/2013 | ELECTRIC - INTERMEDIATE | JMILITEL | Approved | IVRS - Inspection :* |
12/03/2013 | BUILDING - PROGRESS | JMILITEL | Approved | IVRS - Inspection :* |
12/03/2013 | U VALUE FOR WINDOW | JMILITEL | Approved | IVRS - Inspection :* |
12/03/2013 | FRAMING | JMILITEL | Approved | IVRS - Inspection :* |
12/03/2013 | EXT METAL CLIPS/EXT SHEATHING | JMILITEL | Approved | IVRS - Inspection :* |
12/18/2013 | BUILDING - FINAL | JMILITEL | Approved | OK TO OCCUPY |
12/18/2013 | MECHANICAL - FINAL | JMILITEL | Approved | IVRS - Inspection :* |
12/18/2013 | ELECTRIC - FINAL | JMILITEL | Approved | IVRS - Inspection :* |
12/18/2013 | BUILDING - FINAL | JMILITEL | Approved | IVRS - Inspection :* |
12/18/2013 | FIRE - ALARM FINAL | CSCHULTZ | Approved | |
12/18/2013 | FIRE SPKLR - FINAL | CSCHULTZ | Approved | |
12/18/2013 | FIRE - FINAL | CSCHULTZ | Approved |