Permit Details

Status:
C of o
Type:
COMMERCIAL ALTERATION
Address NEW:
5530 E BROADWAY BL
Apply Date:
08/17/2012
Applicant:
METRO TUCSON EXPEDITING & DEVELOPMENT
Description:
TI: RETAIL
Contractors:
  • BARKER MORRISSEY CONTRACTING INC **APA**

Permit Reviews

Permit Number - T12CM05090
Permit Status: C of o
Permit Description: TI: RETAIL
Start Date Submittal Complete Date Status  
08/17/2012 PLANS OK TO SUBMIT - COMM 08/17/2012 COMPLETED Review Details
08/17/2012 COMMERCIAL - TI 09/06/2012 COMPLETED Review Details
09/06/2012 RESUBMITTAL 09/24/2012 COMPLETED Review Details
09/24/2012 RESUBMITTAL 09/25/2012 COMPLETED Review Details
11/15/2012 REVISION - - 1ST 11/15/2012 COMPLETED Review Details
11/27/2012 REVISION - - 2ND 11/27/2012 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T12CM05090
Permit Status: C of o
Permit Description: TI: RETAIL
Total Outstanding Activity Conditions - 1
Date Name
08/17/2012 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Completed Inspections

Permit Status: C of o
Permit Number: T12CM05090
Permit Description: TI: RETAIL
Total Completed Inspections - 35
Date Description Inspector Results Comments
10/18/2012 PLUMBING - PRE SLAB DWALKER Approved IVRS - Inspection :*
10/18/2012 PLUMBING - ROUGH, SOIL DWALKER Approved IVRS - Inspection :*
10/31/2012 BUILDING PRE-SLAB JBURGE Approved IVRS - Inspection :*
11/09/2012 REINFORCED MASONRY PRE-GROUT JBURGE Approved IVRS - Inspection :*
11/13/2012 MECHANICAL - INTERMEDIATE JBURGE Approved IVRS - Inspection :*
11/13/2012 PLUMBING - ABOVE CEILING JBURGE Approved IVRS - Inspection :*
11/13/2012 PLUMBING - INTERMEDIATE JBURGE Approved IVRS - Inspection :*
11/14/2012 PLUMBING - GAS PRESSURE TEST JBURGE Approved IVRS - Inspection :*
11/14/2012 TEP CLEARANCE - AM JBURGE Approved OK TO ENERGIZE PANEL
12/03/2012 NPPO - FINAL MRUSSO Approved
12/03/2012 SIGN - FINAL MRUSSO Approved
12/03/2012 LANDSCAPE - FINAL MRUSSO Approved
12/03/2012 RIGHT OF WAY - FINAL P.Whiddon Approved
12/04/2012 MECHANICAL - ABOVE CEILING JBURGE Approved IVRS - Inspection :*
12/04/2012 ELECTRIC - OUTDOOR LIGHTING JBURGE Approved IVRS - Inspection :*
12/04/2012 PLUMBING - PROGRESS JBURGE Approved IVRS - Inspection :*
12/04/2012 ELECTRIC - PROGRESS JBURGE Approved IVRS - Inspection :*
12/04/2012 PLUMBING - FINAL JBURGE Approved IVRS - Inspection :*
12/04/2012 ELECTRIC - FINAL JBURGE Approved IVRS - Inspection :*
12/05/2012 FIRE SPKLR - FINAL CSCHULTZ Approved
12/05/2012 FIRE - ALARM FINAL CSCHULTZ Approved
12/05/2012 FIRE - FINAL CSCHULTZ Approved
12/05/2012 FIRE - FINAL CSCHULTZ Approved Replace taped and painted heads in the following areas: TV section, Recliners, dinning room tables. X10
Remove two heads next to duct work need to be 4" inches or more away by TV's and Recliners area.
In janitors closet install a ceiling or extend walls all the away to the deck or install uprights above ceiling throughout office and restrooms.
Need new cal plate.
Need a clear access to the inspectors' valve on the southwest corner wall.
Need to test the flow switch with the inspectors test valve that is buried behind the wall southwest corner.
Need lock out on breaker for alarm panel.
12/05/2012 FIRE - ALARM FINAL CSCHULTZ Approved Need lock out on breaker
Need to test the flow switch with the inspectors test valve that is buried behind the wall southwest corner.
12/05/2012 FIRE SPKLR - FINAL CSCHULTZ Approved Replace taped and painted heads in the following areas: TV section, Recliners, dinning room tables. X10
Remove two heads next to duct work need to be 4" inches or more away by TV's and Recliners area.
In janitors closet install a ceiling or extend walls all the away to the deck or install uprights above ceiling throughout office and restrooms.
Need new cal plate.
Need a clear access to the inspectors valve on the southwest corner wall.
12/06/2012 MECHANICAL - FINAL JBURGE Approved
12/06/2012 ELECTRIC - ABOVE CEILING JBURGE Approved
12/06/2012 ELECTRIC - INTERMEDIATE JBURGE Approved
12/06/2012 BUILDING - FINAL JBURGE Approved
12/06/2012 BUILDING - PROGRESS JBURGE Approved
12/06/2012 SHEET ROCK NAILING JBURGE Approved
12/06/2012 BUILDING ABOVE CEILING JBURGE Approved
12/06/2012 FRAMING JBURGE Approved
12/06/2012 ROOF NAILING JBURGE Approved
12/07/2012 ENGINEERING - FINAL MRUSSO Approved