Permit: T12BU00348
Permit Details
Apply Date:
03/14/2012
Applicant:
N/A
Description:
GRADING
Contractors:
- WITHERS CONSTRUCTION L C , D L
Permit Reviews
Permit Number - T12BU00348
Permit Status: Final
Permit Description: GRADING
Start Date | Submittal | Complete Date | Status |
---|---|---|---|
03/14/2012 | PLANS OK TO SUBMIT - GRADING | 03/14/2012 | COMPLETED |
03/14/2012 | GRADING | 04/13/2012 | COMPLETED |
11/22/2013 | RESUBMITTAL - GRADING ALL | 06/19/2014 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T12BU00348
Permit Status: Final
Permit Description: GRADING
Total Outstanding Activity Conditions - 1
Date | Name |
---|---|
03/14/2012 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: Final
Permit Number: T12BU00348
Permit Description: GRADING
Total Completed Inspections - 10
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
09/05/2014 | ENGINEERING PRE-CONSTRUCTION | MRUSSO | Approved | 1) POST A COPY OF YOUR NOI AT THE ENTRANCE TO THE SITE 2) INSTALL A STABILIZE CONSTRUCTION ENTRANCE/EXIT PER YOUR PLAN. CONTRACTOR WILL USE THE EXITING PAVED ROADWAY AS A STABILIZED ENTRANCE TEMPORARY. 3) ENSURE STORM WATER SELF INSPECTIONS ARE PERFORMED PER PLAN. 4) INSTALL A CONCRETE/MATERIALS WASH-OUT WHEN APPLICABLE 5) INSTAL AN ENGINEERED BIRM ALONG THE DOWN SLOPE OF THE PERIMETER OF THE CONSTRUCTION. INSTALL TEMP SEDIMENT CONTROLS INFRONT OF TWO CULVERT PIPES LEAVING THE PROPERTY ALONG THE WEST SIDE. 6) CALL FOR RE-INSPECTION WHEN COMPLETED AZCON#81403 ADAM LEBRECHT 602-526-0194 |
09/25/2014 | GRADING - TIER REV | eleibol1 | Approved | Tier 1 Revision: EOR provided revised sheets (which will later be formally submitted w/ as-builts). Century Link line conflict requires shifting basin & other infrastructure to N of old Los Reales alignment. |
11/21/2014 | STORMWATER INSTALL OF CONTROLS | RLEDONNE | Approved | INSPECTION PER HIGH LIGHT ON C6 FOR STORM DRAIN PIPING. |
12/23/2014 | STORMWATER FOLLOW-UP INSP | MRUSSO | Approved | 1) INSPECTED PEDESTRIAN ACCESS RAMP TO SCALE BLDG. RAMP FORMED PER PLAN - OK TO POUR CONCRETE. 2) NO SIGNIFICANT STORM WATER CONCERNS AT THIS TIME. |
12/23/2014 | GRADING - INTERMEDIATE | MRUSSO | Approved | 1) INSPECTED PEDESTRIAN ACCESS RAMP TO SCALE BLDG. RAMP FORMED PER PLAN - OK TO POUR CONCRETE. 2) NO SIGNIFICANT STORM WATER CONCERNS AT THIS TIME. |
08/13/2015 | LANDSCAPE INSPECTION | MRUSSO | Approved | |
08/13/2015 | STORMWATER FINAL INSPECTION | MRUSSO | Approved | FILE A NOTICE OF TERMINATION WITH ADEQ |
08/13/2015 | GRADING - CHECK FOR ACTIVITY | MRUSSO | Approved | |
10/06/2015 | GRADING - FINAL | MRUSSO | Approved | PRIOR TO FINAL APPROVAL PROVIDE THE FOLLOWING: 1) EL-CERT/FLOODPLAIN USE PERMIT 2) CERT STATEMENT FROM THE ENG OF RECORD 3) PROVIDE AN AS-BUILT PLAN FOR FINAL INSPECTION 4) ENSURE CHANGES MADE AND SHOWN ON PLANS HAVE BEEN APPROVED BY THE COT 5) COMPLETE ALL ASPECTS OF PHASE I SHOWN ON THE APPROVED PLANS |
06/11/2020 | GRADING - REBAR | DROBERTS | Approved | SEE 9190 |