Permit: T12BU00348

Parcel: 14044007E

Inspection Status: Approved

Inspection History: GRADING - INTERMEDIATE

Permit Number - T12BU00348

Inspection Description - GRADING - INTERMEDIATE

Inspection Status - Approved

Date Description Inspector Results Comments
08/13/2015 GRADING - INTERMEDIATE Approved
05/06/2015 GRADING - INTERMEDIATE Continued FOLLOW UP INSPECTION, NO CHANGES AND/OR CONCERNS AT THIS TIME
04/28/2015 GRADING - INTERMEDIATE Continued NO SITE CHANGES AND/OR CONCERNS AT THIS TIME
04/14/2015 GRADING - INTERMEDIATE Continued 1) WALKED SITE WITH SUPERINTENDENT, REVIEWED PLANS
2) MEASURED SLOPE FOR SIDEWALKS THAT HAVE BEEN COMPLETED
3) DISCUSSED ANY CHANGES TO ORIGINAL PLAN
4) PROVIDE AS-BUILT AND CERT STATEMENT
04/03/2015 GRADING - INTERMEDIATE Continued 1) NO SIGNIFICANT STORM WATER CONCERNS AT THIS TIME
2) ANY SIGNIFICANT SITE CHANGES MUST BE SHOWN ON AN APPROVED REVISION
03/26/2015 GRADING - INTERMEDIATE Continued 1) TRUNCATED DOMES ARE NOT REQUIRED AT THIS SITE PER MARTY DUPONT, COT ADA COMPLIANCE SPECIALIST/CARL BUETER, P.E. AND ADASAD.
2) NO SIGNIFICANT STORM WATER CONCERNS AT THIS TIME
02/26/2015 GRADING - INTERMEDIATE Continued 1) WALKED SITE WITH SUPERINTENDENT DISCUSSED APPROVED GRADING PLAN AND STORM WATER REQUIREMENTS
2) PEDESTRIAN ACCESS BEING CONSTRUCTED AND SOME CURB AND CONCRETE SITE WORK BEING INSTALLED.
3) RETENTION/DETENTION BASINS HAVE BEEN ROUGHED-IN
4) WILL FOLLOW UP AS MORE SITE WORK IS BEING ACCOMPLISHED.
5) NO SIGNIFICANT STORM WATER CONCERNS AT THIS TIME
02/25/2015 GRADING - INTERMEDIATE Continued 1) MET WITH SUPERINTENDENT TO DISCUSS SITE/GRADING
2) NO SIGNIFICANT STORM WATER CONCERNS AT THIS TIME
01/20/2015 GRADING - INTERMEDIATE Continued 1) INSPECTED INSTALL OF PVC-STORM PIPE AND HDPE PIPE @ DRAINAGE CHANNEL/BASIN.
2) PVC PIPE FOR FUTURE USE
3) STORM PIPE INSTALLED PER APPROVED PLANS.
4) NO SIGNIFICANT STORM WATER CONCERNS AT THIS TIME

OK TO COVER PIPE (PICTURES TAKEN)
12/23/2014 GRADING - INTERMEDIATE Continued 1) INSPECTED PEDESTRIAN ACCESS RAMP TO SCALE BLDG.
RAMP FORMED PER PLAN - OK TO POUR CONCRETE.
2) NO SIGNIFICANT STORM WATER CONCERNS AT THIS TIME.
12/19/2014 GRADING - INTERMEDIATE Continued NO CHANGES NO CONCERNS
12/18/2014 GRADING - INTERMEDIATE Continued
11/14/2014 GRADING - INTERMEDIATE Continued NO CHANGES AND/OR CONCERNS AT THIS TIME
11/05/2014 GRADING - INTERMEDIATE Continued NO SIGNIFICANT STORM WATER CONCERNS AT THIS TIME
NO SITE/GRADING CONCERNS