Permit Details

Status:
C of o
Type:
COMMERCIAL ALTERATION
Apply Date:
10/11/2011
Applicant:
URIAS, CHARLES GILBERT
Description:
TI; SANDWICH SHOP & MEAT MARKET
Architects:
  • URIAS, CHARLES GILBERT
Contractors:
  • CAPITAL CONSTRUCTION L L C

Permit Reviews

Permit Number - T11CM03219
Permit Status: C of o
Permit Description: TI; SANDWICH SHOP & MEAT MARKET
Start Date Submittal Complete Date Status  
01/04/2012 REVISION - - 1ST 01/05/2012 COMPLETED Review Details
10/11/2011 COMMERCIAL - TI 10/18/2011 COMPLETED Review Details
10/18/2011 COMMERCIAL - TI 10/27/2011 COMPLETED Review Details
10/27/2011 RESUBMITTAL 10/31/2011 COMPLETED Review Details
10/31/2011 RESUBMITTAL 11/17/2011 COMPLETED Review Details

Completed Inspections

Permit Status: C of o
Permit Number: T11CM03219
Permit Description: TI; SANDWICH SHOP & MEAT MARKET
Total Completed Inspections - 24
Date Description Inspector Results Comments
11/29/2011 PLUMBING - PRE SLAB BBENEDON Approved IVRS - Inspection :*
12/05/2011 FRAMING JBURGE Approved IVRS - Inspection :*
12/06/2011 PLUMBING - INTERMEDIATE BBENEDON Approved IVRS - Inspection :*
1) IN WALL OK PENDING DELETION OF PIPE INSULATION
2) OVERHEAD REQUIRES SUPPORT AND ISOLATION
12/15/2011 PLUMBING - ROUGH, SOIL BBENEDON Approved IVRS - Inspection :
See detailed listing on site.| 999*
1) EXPLAINED TO STEVE 272-0621 THAT ENGINEERING IS REQUIRED TO CHANGE TYPE OF HYDRO MECHANICAL INTERCEPTOR AND THAT I CANNOT GIVE ANY APPROVAL WITHOUT A CITY APPROVED REVISION
2) FLOW CONTROL MAY NOT BE BURRIED BELOW SLAB
3) A 3 X 2 RESTRICTION AT OUTLET IS A CODE VIOLATION
4) INTERCEPTOR REQUIRES A VENT
5) PLEASE HAVE ALL OF YOUR CHANGES REVISED AND APPROVED
6) PROVIDE REVISION TO PLUMBING INSPECTOR
12/15/2011 PLUMBING - PROGRESS BBENEDON Approved IVRS - Inspection :*
12/30/2011 MECHANICAL - ABOVE CEILING MRAMBER Approved IVRS - Inspection :*
12/30/2011 ELECTRIC - PROGRESS MRAMBER Approved IVRS - Inspection :*
12/30/2011 ELECTRIC - TEMP POWER FOR TEST MRAMBER Approved IVRS - Inspection :*
01/03/2012 TEP CLEARANCE - AM CPIERCE Approved
01/09/2012 PLUMBING - ABOVE CEILING BBENEDON Approved IVRS - Inspection :*
01/19/2012 FIRE - FINAL WMOTTO Approved
01/19/2012 FIRE - KITCHEN EXH HOOD FINAL WMOTTO Approved 1. THERE IS NO KITCHEN HOOD.
01/19/2012 FIRE SPKLR - FINAL WMOTTO Approved
01/19/2012 BUILDING ABOVE CEILING AQUIROZ Approved IVRS - Inspection :*
01/19/2012 MECHANICAL - INTERMEDIATE AQUIROZ Approved IVRS - Inspection :*
01/19/2012 ELECTRIC - INTERMEDIATE AQUIROZ Approved IVRS - Inspection :*
01/24/2012 BUILDING - FINAL JBURGE Approved IVRS - Inspection :*
01/24/2012 PLUMBING - FINAL JBURGE Approved IVRS - Inspection :*
11/20/2012 HEALTH DEPT - FINAL 724-7908 pima county Approved
11/20/2012 MECHANICAL - FINAL LHANLY Approved
11/20/2012 MECHANICAL - PROGRESS LHANLY Approved
11/20/2012 MECHANICAL - HOODS LHANLY Approved
11/20/2012 ELECTRIC - FINAL LHANLY Approved
11/20/2012 ELECTRIC - ABOVE CEILING LHANLY Approved

Documents

File Name Document Type  
C OF O_11-21-2012.TIF CERT OF OCC VIEW
001_T-1.TIF CONSTRPLANS VIEW
002_A-1.TIF CONSTRPLANS VIEW
003_A-2.TIF CONSTRPLANS VIEW
004_A-3.TIF CONSTRPLANS VIEW
005_A-4.TIF CONSTRPLANS VIEW
006_A-5.TIF CONSTRPLANS VIEW
007_A-6.TIF CONSTRPLANS VIEW
008_P-1.TIF CONSTRPLANS VIEW
009_P-2.TIF CONSTRPLANS VIEW
010_P-3.TIF CONSTRPLANS VIEW
011_M-1.TIF CONSTRPLANS VIEW
012_E-1.TIF CONSTRPLANS VIEW
013_E-2.TIF CONSTRPLANS VIEW
014_E-3.TIF CONSTRPLANS VIEW
015_E-4.TIF CONSTRPLANS VIEW
016_E-5.TIF CONSTRPLANS VIEW
017_E-6.TIF CONSTRPLANS VIEW
None DOCUMENTS VIEW