Permit Details

Status:
Final
Type:
COMMERCIAL ALTERATION
Apply Date:
07/07/2011
Applicant:
LUKE WILSON
Description:
TI: BROOKLINE COLLEGE
Contractors:
  • VISTA GENERAL L L C

Permit Reviews

Permit Number - T11CM02131
Permit Status: Final
Permit Description: TI: BROOKLINE COLLEGE
Start Date Submittal Complete Date Status  
01/31/2012 REVISION - - 2ND 02/08/2012 COMPLETED Review Details
07/07/2011 PLANS OK TO SUBMIT - COMM 07/07/2011 COMPLETED Review Details
07/07/2011 COMMERCIAL - TI 09/13/2011 COMPLETED Review Details
09/13/2011 RESUBMITTAL 10/03/2011 COMPLETED Review Details
10/03/2011 RESUBMITTAL 10/20/2011 COMPLETED Review Details
10/20/2011 RESUBMITTAL 10/24/2011 COMPLETED Review Details
10/24/2011 RESUBMITTAL 10/27/2011 COMPLETED Review Details
12/13/2011 REVISION - - 1ST 12/13/2011 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T11CM02131
Permit Status: Final
Permit Description: TI: BROOKLINE COLLEGE
Total Outstanding Activity Conditions - 1
Date Name
07/07/2011 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Completed Inspections

Permit Status: Final
Permit Number: T11CM02131
Permit Description: TI: BROOKLINE COLLEGE
Total Completed Inspections - 25
Date Description Inspector Results Comments
11/02/2011 PLUMBING - PRE SLAB RRICH Approved IVRS - Inspection :*
1) SAME AREA EAST ONLY OK
12/02/2011 ELECTRIC - ABOVE CEILING DSANTACR Approved IVRS - Inspection :*
1) OK PHASE ONE EXCEPT POWER POLES, PROJECTORS, EXIT LTGS, JUST EAST OF EXISTING DEMIZING WALL, DENTAL LAB, SNACK SHOP, RESTROOMS AND MESSAGE THEROPY
12/09/2011 PLUMBING - INTERMEDIATE BBENEDON Approved IVRS - Inspection :*
1) COMPLETE PIPE INSULATION, REINSTALL SUPPORTS AS NEEDED
2) SUPPORT PIPING AT EACH END AN NOT TO EXCEED MINIMUM REQUIRED DISTANCE
12/14/2011 ELECTRIC - FINAL RMORENO Approved IVRS - Inspection :*
1) PHASE I EM FOR SOUTH FRONT DOORS NOT WORKING
2) BREAKER HANDLES MISSING 1102 FOR POWER POLE
12/14/2011 PLUMBING - PROGRESS BBENEDON Approved IVRS - Inspection :*
1) VENTS REQUIRE UV PROTECTION AND CLEARANCE
2) ISOLATE CU FROM GRID WIRES
3) OVERHEAD DWV REQUIRES SUPPORT AT EACH CHANGE OF DIRECTION, NOT EXCEED 4', CU SUPPORTS NOT TO EXCEED 6'
4) PROVIDE LISTED CLEANOUT PLUGS FOR SCREWS
5) TRAP ARM MAY NOT CHANGE ELEVATION
6) VACUUM RELIEF VAVLE SHOWN
7) EAST PLAN REVISION OK
12/14/2011 PLUMBING - ROUGH, SOIL BBENEDON Approved IVRS - Inspection :*
12/15/2011 PLUMBING - FINAL BBENEDON Approved IVRS - Inspection :*
1) PLUMBING DEMO REQUIRES PERM CAPS AND INSPECTION
2) WORK NOT DONE WILL REQUIRE REV.
3) SEAL AND CLIP NEW SINKS AND MAKE CLEANOUTS ACCESSIBLE
12/15/2011 PLUMBING - ABOVE CEILING BBENEDON Approved IVRS - Inspection :*
1) EAST SIDE PHASE I
12/16/2011 MECHANICAL - FINAL JMILITEL Approved IVRS - Inspection :*
1) OK FOR FINAL PHASE I
12/16/2011 BUILDING - FINAL MHENSON Approved IVRS - Inspection :*
1) OK TO MOVE EQUIPMENT/FURNITURE
2) NEED TO SEE LEERAY REGARDING TEMP C OF O
3) NEED ELECTRIC OK FOR PHASE I
4) NEE ENGINEERING OK FOR PHASE I
5) RAMP TO HAVE HANDRAILS BOTH SIDES DIRECTIONAL SIGN TO ACCESSIBLE ENTRANCE
12/19/2011 NPPO - FINAL DROBERTS Approved
12/19/2011 SIGN - FINAL DROBERTS Approved
12/19/2011 LANDSCAPE - FINAL DROBERTS Approved
12/19/2011 ENGINEERING - FINAL DROBERTS Approved
12/22/2011 MECHANICAL - INTERMEDIATE JMILITEL Approved IVRS - Inspection :*
ALL EXISTING DUCTS + DIFFUSERS OK
NEED TO SEE CONDESATE DRAINS + NEW DUCT CONNECTIONS
12/28/2011 ELECTRIC - INTERMEDIATE RMORENO Approved IVRS - Inspection :*
1) 1016, 110, 122, 1001-1004 AND CEILINGS OK
2) 1057, 1055 AND WALLS OK
12/28/2011 SHEET ROCK NAILING WLAHR Approved IVRS - Inspection :*
12/28/2011 FRAMING WLAHR Approved IVRS - Inspection :*
12/29/2011 BUILDING ABOVE CEILING WLAHR Approved IVRS - Inspection :*
12/30/2011 MECHANICAL - ABOVE CEILING MRAMBER Approved IVRS - Inspection :*
01/26/2012 FIRE - ALARM FINAL MBrown Approved
01/26/2012 FIRE SPKLR - FINAL MBrown Approved
01/26/2012 FIRE - FINAL MBrown Approved
02/17/2012 ELECTRIC - UNDERGROUND RMORENO Approved
02/17/2012 BUILDING - PROGRESS JBURGE Approved IVRS - Inspection :*

Documents

File Name Document Type  
C OF O_02-17-2012.TIF CERT OF OCC VIEW
001_G1.1.TIF CONSTRPLANS VIEW
002_A1.0.TIF CONSTRPLANS VIEW
003_A2.0.TIF CONSTRPLANS VIEW
004_A2.0W.TIF CONSTRPLANS VIEW
005_A2.0E.TIF CONSTRPLANS VIEW
006_A2.1.TIF CONSTRPLANS VIEW
007_A2.1W.TIF CONSTRPLANS VIEW
008_A2.1E.TIF CONSTRPLANS VIEW
009_A2.2.1.TIF CONSTRPLANS VIEW
010_A2.2.2.TIF CONSTRPLANS VIEW
011_A2.2.3.TIF CONSTRPLANS VIEW
012_A2.3.TIF CONSTRPLANS VIEW
013_A2.3.TIF CONSTRPLANS VIEW
014_A2.3W.TIF CONSTRPLANS VIEW
015_A2.3E.TIF CONSTRPLANS VIEW
016_A2.4W.TIF CONSTRPLANS VIEW
017_A2.4E.TIF CONSTRPLANS VIEW
018_A3.1.TIF CONSTRPLANS VIEW
019_A3.1W.TIF CONSTRPLANS VIEW
020_A3.1E.TIF CONSTRPLANS VIEW
021_A4.1.TIF CONSTRPLANS VIEW
022_A4.1W.TIF CONSTRPLANS VIEW
023_A4.1E.TIF CONSTRPLANS VIEW
024_A5.1.TIF CONSTRPLANS VIEW
025_A5.2.TIF CONSTRPLANS VIEW
026_A5.3.TIF CONSTRPLANS VIEW
027_A5.4.TIF CONSTRPLANS VIEW
028_A6.1.TIF CONSTRPLANS VIEW
029_A6.2.TIF CONSTRPLANS VIEW
030_A7.1.TIF CONSTRPLANS VIEW
031_S1.TIF CONSTRPLANS VIEW
032_MD1.1.TIF CONSTRPLANS VIEW
033_MD1.2.TIF CONSTRPLANS VIEW
034_M1.0.TIF CONSTRPLANS VIEW
035_M1.1.TIF CONSTRPLANS VIEW
036_M1.2.TIF CONSTRPLANS VIEW
037_E0.1.TIF CONSTRPLANS VIEW
038_E2.1.TIF CONSTRPLANS VIEW
039_E2.2.TIF CONSTRPLANS VIEW
040_E2.3.TIF CONSTRPLANS VIEW
041_E2.4.TIF CONSTRPLANS VIEW
042_E3.1.TIF CONSTRPLANS VIEW
043_E3.2.TIF CONSTRPLANS VIEW
044_E3.3.TIF CONSTRPLANS VIEW
045_E3.4.TIF CONSTRPLANS VIEW
046_E3.5.TIF CONSTRPLANS VIEW
047_E5.1.TIF CONSTRPLANS VIEW
048_E5.2.TIF CONSTRPLANS VIEW
049_E5.3.TIF CONSTRPLANS VIEW
050_P0.1.TIF CONSTRPLANS VIEW
051_P2.1.TIF CONSTRPLANS VIEW
052_P2.2.TIF CONSTRPLANS VIEW
053_PD1.1.TIF CONSTRPLANS VIEW
054_PD1.2.TIF CONSTRPLANS VIEW
None DOCUMENTS VIEW