Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T11CM02131

Parcel: 12809006B


Addresses:

5441 E 22ND ST #125


Inspection Status: Approved

Inspection History: PLUMBING - PROGRESS

Permit Number - T11CM02131

Inspection Description - PLUMBING - PROGRESS

Inspection Status - Approved

Date Description Inspector Results Comments
02/17/2012 PLUMBING - PROGRESS Approved IVRS - Inspection :*
01/26/2012 PLUMBING - PROGRESS Not ready for Inspection IVRS - Inspection :*
12/14/2011 PLUMBING - PROGRESS Not ready for Inspection IVRS - Inspection :*
1) VENTS REQUIRE UV PROTECTION AND CLEARANCE
2) ISOLATE CU FROM GRID WIRES
3) OVERHEAD DWV REQUIRES SUPPORT AT EACH CHANGE OF DIRECTION, NOT EXCEED 4', CU SUPPORTS NOT TO EXCEED 6'
4) PROVIDE LISTED CLEANOUT PLUGS FOR SCREWS
5) TRAP ARM MAY NOT CHANGE ELEVATION
6) VACUUM RELIEF VAVLE SHOWN
7) EAST PLAN REVISION OK
12/09/2011 PLUMBING - PROGRESS Not ready for Inspection IVRS - Inspection :*