Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Details

Status:
L of c
Type:
SINGLE FAMILY ADDITION
Address:
6001 E 32ND ST
Address NEW:
6001 E 32ND ST
Apply Date:
05/13/2011
Applicant:
JESUS GAYTAN
Description:
ADDITION:2ND STORY & OUT BUILDINGS:ELECTRIC UPGRADE:T10DV06702

Permit Reviews

Permit Number - T11CM01464
Permit Status: L of c
Permit Description: ADDITION:2ND STORY & OUT BUILDINGS:ELECTRIC UPGRADE:T10DV06702
Start Date Submittal Complete Date Status  
05/13/2011 RESIDENTIAL - BLDG/ZONING/ENGINE/WWM 05/18/2011 COMPLETED Review Details
05/31/2011 REVISION - - 1ST 08/02/2011 COMPLETED Review Details
10/15/2012 REVISION - - 3RD 10/15/2012 COMPLETED Review Details
11/09/2011 REVISION - - 2ND 11/09/2011 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T11CM01464
Permit Status: L of c
Permit Description: ADDITION:2ND STORY & OUT BUILDINGS:ELECTRIC UPGRADE:T10DV06702
Total Outstanding Activity Conditions - 1
Date Name
05/13/2011 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Completed Inspections

Permit Status: L of c
Permit Number: T11CM01464
Permit Description: ADDITION:2ND STORY & OUT BUILDINGS:ELECTRIC UPGRADE:T10DV06702
Total Completed Inspections - 15
Date Description Inspector Results Comments
08/05/2011 EXCAVATION/LAYOUT REBAR & ZON WLAHR Approved IVRS - Inspection :
See detailed listing on site.| 999*
1) PLANS NEED TO SHOW WHAT IS DONE ON SITE (REVISION)
2) NEED SUPERVISORS PERMISSION TO TRY TO GET CLAYTON TO JOB SITE BEFORE PLAN REVISONS ARE MADE
3) MAX OVERCURRENT PROTECTION FOR 12 AWG IS 20 AMPS ON KITCHEN CIRCUIT
4) LOOSE NEUTRAL WIRE IN PANEL-BREAKER DBL LUGGED
08/05/2011 ELECTRIC - RECONNECT WLAHR Approved IVRS - Inspection :*
08/05/2011 TEP CLEARANCE - AM DROBEY Approved
08/08/2011 ELECTRIC - SERVICE UPGRADE RMAJUTA Approved 1) 8/8/11-CALLED CARLOS RAMIREZ WITH RAY MAJUTA AND LEFT MESSAGE FOR HIM TO PLEASE RETURN THE CALL
2) REVIEWED PERMITS WITH CLAYTON FOR 1ST STORY ISSUED 10/96, WITH ONLY ELECTRICAL INTERMEDIATE APPROVED
3) IT WAS DETERMINED THAT AT THIS TIME A STRUCTURAL ENGINEER NEEDS TO SUBMIT PLANS FOR APPROVAL PRIOR TO CONTINUING CONSTRUCTION
4) APPROVAL FOR 1ST STORY CONSTRUCTION AND OCCUPANCY HAS NOT BEEN ISSUED
8/9/11:
1) RAY MAJUTA SPOKE WITH CARLOS AND NOTIFIED HIM THAT HE NEEDED TO OBTAIN PLANS FROM A STRUCTURAL ENGINEER AND SUBMIT TO THE CITY OF TUCSON FOR APPROVAL
08/17/2012 ELECTRIC - INTERMEDIATE WLAHR Approved IVRS - Inspection :*
09/27/2012 ROOF NAILING WLAHR Approved IVRS - Inspection :*
09/27/2012 EXT METAL CLIPS/EXT SHEATHING WLAHR Approved IVRS - Inspection :$
09/28/2012 FRAMING WLAHR Approved IVRS - Inspection :*
09/28/2012 MECHANICAL - INTERMEDIATE WLAHR Approved IVRS - Inspection :*
10/05/2012 SHEET ROCK NAILING WLAHR Approved IVRS - Inspection :*
11/06/2012 BUILDING - FINAL WLAHR Approved -HANDRAIL NEEDED AT STAIRWAY TO CODE
-MAKE UP ALL OUTLETS AND SWITCHES WITH COVERPLATES
-SUB-PANEL REQUIRES BREAKERS TO BE SAME BRAND AS PANEL
-ARC FAULT PROTECT ALL BEDROOM CIRCUITS
-SMOKE DETECTOR NEEDED IN BEDROOM CEILING
-U-VALVE FOR SITE BUILT WINDOW
-VERIFICATION OF OUTBUILDINGS ON PERMIT
-LOWER BEDROOM EGRESS WINDOW MAXIMUM SILL HEIGHT OF 44" OR DELIET BEDROOM FOR OFFICE PER HOMEOWNER
-FINISH PLAYROOM TO CODE
-EXTERIOR FITTINGS NEEDED FOR RACEWAYS AND EXTERIOR BOXES
-OVERSIZED BREAKERS FOR CONDUCTIORS AT MAIN PANEL
-PANEL SCHEDULE NEEDED FOR PANELS
-NEUTRALS NEEDED TO BE UNDER SCREWS TO NEUTRAL BAR
11/19/2012 ELECTRIC - FINAL RMORENO Approved NOT READY
07/28/2015 MECHANICAL - FINAL JBURGE Approved IVRS - Inspection :*
07/28/2015 OUTDOOR LIGHTING FINAL JBURGE Approved IVRS - Inspection :*
07/28/2015 U VALUE FOR WINDOW JBURGE Approved IVRS - Inspection :*

Documents

File Name Document Type  
None LETTER OF COMPLETION VIEW
001_SITE.TIF CONSTRPLANS VIEW
002_FOOTING.TIF CONSTRPLANS VIEW
003_SPECS.TIF CONSTRPLANS VIEW
004_FLOOR.TIF CONSTRPLANS VIEW
005_ELEC.TIF CONSTRPLANS VIEW
006_MECH.TIF CONSTRPLANS VIEW
001_MECH PLAN.TIF CONSTRPLANS VIEW
007_2ND FL.TIF CONSTRPLANS VIEW
008_2ND FL ELEC.TIF CONSTRPLANS VIEW
009_2ND FL MECH.TIF CONSTRPLANS VIEW
010_FRAMING.TIF CONSTRPLANS VIEW
011_ROOF.TIF CONSTRPLANS VIEW
012_ELEV.TIF CONSTRPLANS VIEW
013_ELEV.TIF CONSTRPLANS VIEW
001_FOUNDATION.TIF CONSTRPLANS VIEW
002_DETAIL.TIF CONSTRPLANS VIEW
003_ELEV.TIF CONSTRPLANS VIEW
001_FLOOR FRAMING.TIF CONSTRPLANS VIEW
None DOCUMENTS VIEW