Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 09/28/2012 | FRAMING | Approved | IVRS - Inspection :* | |
| 09/27/2012 | FRAMING | Denied | -STAPE ALL CONDUCTOTS WITHIN 8" OF BOXES -NAIL AND SECURE ALL ELECTRICAL BOXES -BLANK OFF UNUSED KNOCK OUTS AT SUBPANEL -2LAYER OF OSB NEEDED ON FLOOT FOR MINIMUM CODE REQUIREMENTS ABOVE ITEMS FOR BEDROOM LESS CLOSET AREA |
|
| 08/17/2012 | FRAMING | Not ready for Inspection | IVRS - Inspection :* | |
| 08/16/2012 | FRAMING | Denied | ADD OUTLET TO COMPLY WITH 12' RULE. MOVE LIGHT IN CLOSET TO COMPLY WITH DISTANCE FROM SHELVING. STAPLE WIRES WITHIN 8" OF BOXES. REMOVE BOXES INSIDE STUD CAVITIES BY WINDOW. |
|
| 07/31/2012 | FRAMING | Not ready for Inspection | COMPLETE EXTERIOR SHEATHING BEFORE COVERING UP WITH LATH |