Permit Details

Status:
C of o
Type:
COMMERCIAL ALTERATION
Address:
1043 N KOLB RD
Apply Date:
11/05/2010
Applicant:
N/A
Description:
TI: DONUT SHOP
Contractors:
  • A L SANTA MARIA DESIGN AND CONSTRUCTION

Permit Reviews

Permit Number - T10CM03114
Permit Status: C of o
Permit Description: TI: DONUT SHOP
Start Date Submittal Complete Date Status  
01/31/2011 REVISION - - 1ST 01/31/2011 ACTIVE Review Details
11/05/2010 COMMERCIAL - TI 11/09/2010 COMPLETED Review Details
11/05/2010 OTHER 11/09/2010 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T10CM03114
Permit Status: C of o
Permit Description: TI: DONUT SHOP
Total Outstanding Activity Conditions - 1
Date Name
11/05/2010 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Completed Inspections

Permit Status: C of o
Permit Number: T10CM03114
Permit Description: TI: DONUT SHOP
Total Completed Inspections - 29
Date Description Inspector Results Comments
11/10/2010 ELECTRIC - RECONNECT JBURGE Approved IVRS - Inspection :*
11/12/2010 TEP CLEARANCE - AM JWEATHER Approved RECN CLEARED PER J. BURGE
11/18/2010 PLUMBING - PRE SLAB BBENEDON Approved IVRS - Inspection :*
11/18/2010 PLUMBING - ROUGH, SOIL BBENEDON Approved IVRS - Inspection :*
12/10/2010 MECHANICAL - ABOVE CEILING JMILITEL Approved IVRS - Inspection :*
1) SUPPORT FLEX DUCTS
12/10/2010 MECHANICAL - INTERMEDIATE JMILITEL Approved IVRS - Inspection :*
12/10/2010 SHEET ROCK NAILING JBURGE Approved IVRS - Inspection :*
12/10/2010 BUILDING ABOVE CEILING JBURGE Approved IVRS - Inspection :*
12/10/2010 FRAMING JBURGE Approved IVRS - Inspection :*
12/10/2010 ELECTRIC - INTERMEDIATE RMORENO Approved IVRS - Inspection :*
12/13/2010 PLUMBING - ABOVE CEILING BBENEDON Approved IVRS - Inspection :*
12/13/2010 PLUMBING - INTERMEDIATE BBENEDON Approved IVRS - Inspection :*
12/16/2010 ELECTRIC - ABOVE CEILING RMORENO Approved IVRS - Inspection :*
1) TILES OFF ON 4 BOXES
12/17/2010 MECHANICAL - HOODS JMILITEL Approved IVRS - Inspection :*
1) ABOVE CEILING IS OK
2) CHECKED WELDS ON GREASE DUCT
3) OK TO DBL WRAP AND INSTALL
4) TERMINATE CONDENSATE TO AN APPROVED LOCATION
5) PROVIDE A FRESH AIR INTAKE
6) A/C UNIT MISSING FLUE HOOD
7) PROVIDE DRAIN FOR EVAP COOLER
12/21/2010 NPPO - FINAL DROBERTS Approved
12/21/2010 ENGINEERING - FINAL DROBERTS Approved
12/21/2010 LANDSCAPE - FINAL DROBERTS Approved
12/21/2010 PLUMBING - GAS PRESSURE TEST BBENEDON Approved IVRS - Inspection :*
12/21/2010 RIGHT OF WAY - FINAL P.Whiddon Approved
01/04/2011 HEALTH DEPT - FINAL 724-7908 NRAMIREZ Approved PER INSP CARD
01/18/2011 PLUMBING - GAS PRESS TEST FNL BBENEDON Approved IVRS - Inspection :*
01/27/2011 PLUMBING - PROGRESS BBENEDON Approved IVRS - Inspection :*
01/27/2011 ELECTRIC - FINAL RMORENO Approved IVRS - Inspection :*
01/31/2011 FIRE - KITCHEN EXH HOOD FINAL CSCHULTZ Approved Hood is approved as is, one fryer and one gas convection oven under hood. Need to change gas line piping; changed by installing elbow to piping and removing the tee next to oven so no gas appliance can be installed outside of hood coverage. Okay to have electrical oven outside of hood no gas

2. Also need to revise plans showing changes to appliance line up and that convection oven outside of hood is electrical only.
01/31/2011 SIGN - FINAL JYBARRA Approved
02/01/2011 PLUMBING - FINAL RRICH Approved IVRS - Inspection :*
02/02/2011 MECHANICAL - FINAL JMILITEL Approved IVRS - Inspection :*
02/02/2011 FIRE - FINAL DRamirez Approved Approved 2/2/11
02/02/2011 BUILDING - FINAL JBURGE Approved IVRS - Inspection :*

Documents

File Name Document Type  
C OF O_02-04-2011.TIF CERT OF OCC VIEW
001_CVR.TIF CONSTRPLANS VIEW
002_A1.TIF CONSTRPLANS VIEW
003_A2.TIF CONSTRPLANS VIEW
004_P1.TIF CONSTRPLANS VIEW
005_P2.TIF CONSTRPLANS VIEW
006_M1.TIF CONSTRPLANS VIEW
007_M2.TIF CONSTRPLANS VIEW
008_E1.TIF CONSTRPLANS VIEW
009_E2.TIF CONSTRPLANS VIEW
None DOCUMENTS VIEW