Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - INTERMEDIATE
Permit Number - T10CM03114
Inspection Description - PLUMBING - INTERMEDIATE
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
12/13/2010 | PLUMBING - INTERMEDIATE | Approved | IVRS - Inspection :* | |
12/10/2010 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* 1) ALL OK EXCEPT AT 3 COMP SINK |
|
11/16/2010 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* 1) YOU HAVE A OFF SET MADE WITH 4 1/8" BENDS TOTALING 180 DEGREE CHANGE OF DIRECTION 2) ELIMINATE 2 1/8" BENDS TO SATISFY UPC 707.5 (YOU DO NOT NEED A FCO FOR MS) 3) PROVIDE 1/4" PER SLOPE; 708 4) ALSO NOTE SECTION 1014.2.1 FOR FLOW CONTROL VENTING, IF NOT USING AN INTERCEPTOR WITH AN INTERNAL FLOW CONTROL 5) RED LINE ANY CHANGES TO YOUR PLAN |