Permit: T10CM01647
Permit Details
Apply Date:
06/17/2010
Applicant:
N/A
Description:
TI: RESTAURANT (SUBWAY)
Architects:
- TIENI, ROBERT MICHAEL
Contractors:
- A R G CONSTRUCTION INC
Permit Reviews
Permit Number - T10CM01647
Permit Status: Expired
Permit Description: TI: RESTAURANT (SUBWAY)
Start Date | Submittal | Complete Date | Status |
---|---|---|---|
06/17/2010 | COMMERCIAL TI | 06/24/2010 | COMPLETED |
06/24/2010 | RESUBMITTAL | 07/07/2010 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T10CM01647
Permit Status: Expired
Permit Description: TI: RESTAURANT (SUBWAY)
Total Outstanding Activity Conditions - 1
Date | Name |
---|---|
06/17/2010 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Outstanding Inspections
Permit Status: Expired
Permit Number: T10CM01647
Permite Description: TI: RESTAURANT (SUBWAY)
Total Outstanding Inspections - 5
Last Inspection Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
MECHANICAL - INTERMEDIATE | N/A | Not Inspected | ||
07/26/2010 | MECHANICAL - ABOVE CEILING | N/A | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) THE ENTIRE STORE WAS REDUCTED 2) PROVIDE A COMPLETE MECHANICAL PLAN WITH ALL NEW DUCT SIZES AND CFM REQUIREMENTS 3) SUPPORT DIFFUSER TO STRUCTURE 4) DO NOT USE PRODUCT STRAPS TO SUPPORT ANY DUCTS 5) STRAP ALL FLEX UP OFF OF LIGHTS 6) FOR FINAL PROVIDE A COMPLETE AIR BALANCE REPORT 7) TERMINATE CONDENSATE TO AN APPROVED LOCATION 8) PAINT EXPOSED ARMAFLEX WITH PROTECTIVE COATING |
07/26/2010 | MECHANICAL - FINAL | N/A | Denied | IVRS - Inspection : See detailed listing on site.| 999* |
07/27/2010 | SIGN - FINAL | N/A | Partial Approval | IVRS - Inspection :* need to final elec on t10ot00868 before c/o can be issued or HAVE SIGN COMPANY POST BOND FOR SIGN COMPLETION |
07/28/2010 | PLUMBING - FINAL | N/A | Not ready for Inspection | IVRS - Inspection :* 1) COMPLETE NOTES 2, 9 AND 10, ALSO YOU HAVE A LEAK 2) SUPPORT ICE MAKER DRAIN AND PROVIDE AIR GAP 3) SEE UPC CODE SECTION 602.2 REQUIRING EACH CONNECTION TO BE SEPERATELY PROTECTED 4) YOU WILL NEED TO RECERT RP |
Completed Inspections
Permit Status: Expired
Permit Number: T10CM01647
Permit Description: TI: RESTAURANT (SUBWAY)
Total Completed Inspections - 18
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
07/14/2010 | FRAMING | JBURGE | Approved | IVRS - Inspection :* |
07/15/2010 | SHEET ROCK NAILING | JBURGE | Approved | IVRS - Inspection :* |
07/15/2010 | ELECTRIC - INTERMEDIATE | RJIROUDE | Approved | IVRS - Inspection :* |
07/20/2010 | PLUMBING - PRE SLAB | BBENEDON | Approved | IVRS - Inspection :* |
07/21/2010 | PLUMBING - ABOVE CEILING | BBENEDON | Approved | IVRS - Inspection :* |
07/22/2010 | PLUMBING - INTERMEDIATE | BBENEDON | Approved | IVRS - Inspection :* |
07/22/2010 | PLUMBING - ROUGH, SOIL | BBENEDON | Approved | IVRS - Inspection :* |
07/23/2010 | ELECTRIC - ABOVE CEILING | RMORENO | Approved | |
07/23/2010 | ROOF NAILING | JBURGE | Approved | IVRS - Inspection :* |
07/23/2010 | ELECTRIC - FINAL | RMORENO | Approved | IVRS - Inspection :* |
07/26/2010 | BUILDING - FINAL | JBURGE | Approved | IVRS - Inspection :* 1) PENDING PLUMBING FINAL |
07/26/2010 | PLUMBING - PROGRESS | BBENEDON | Approved | IVRS - Inspection :* |
07/27/2010 | FIRE SPKLR - FINAL | LTHOMAS | Approved | |
07/27/2010 | FIRE - FINAL | LTHOMAS | Approved | |
07/27/2010 | RIGHT OF WAY - FINAL | P.Whiddon | Approved | |
07/28/2010 | ENGINEERING - FINAL | MRUSSO | Approved | |
07/28/2010 | NPPO - FINAL | MRUSSO | Approved | |
07/28/2010 | LANDSCAPE - FINAL | MRUSSO | Approved |