Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Details

Status:
Expired
Type:
COMMERCIAL ALTERATION
Apply Date:
04/27/2010
Applicant:
N/A
Description:
TI: RESTAURANT; SUBWAY
Contractors:
  • A R G CONSTRUCTION INC

Permit Reviews

Permit Number - T10CM01138
Permit Status: Expired
Permit Description: TI: RESTAURANT; SUBWAY
Start Date Submittal Complete Date Status  
04/27/2010 COMMERCIAL TI 04/27/2010 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T10CM01138
Permit Status: Expired
Permit Description: TI: RESTAURANT; SUBWAY
Total Outstanding Activity Conditions - 1
Date Name
04/27/2010 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Outstanding Inspections

Permit Status: Expired
Permit Number: T10CM01138
Permite Description: TI: RESTAURANT; SUBWAY
Total Outstanding Inspections - 13
Last Inspection Date Description Inspector Results Comments
BUILDING - FINAL N/A Not Inspected
ELECTRIC - INTERMEDIATE N/A Not Inspected
ELECTRIC - FINAL N/A Not Inspected
PLUMBING - INTERMEDIATE N/A Not Inspected
PLUMBING - PROGRESS N/A Not Inspected
PLUMBING - FINAL N/A Not Inspected
MECHANICAL - HOODS N/A Not Inspected
MECHANICAL - FINAL N/A Not Inspected
FIRE SPKLR - FINAL N/A Not Inspected
HEALTH DEPT - FINAL 724-7908 N/A Not Inspected
05/21/2010 PLUMBING - ROUGH, SOIL N/A Partial Approval IVRS - Inspection :*
1) COMPLETE LIST FROM 5/20/10
05/24/2010 PLUMBING - PRE SLAB N/A Partial Approval IVRS - Inspection :*
1) WAITING ON ITEM #4 FROM 5/20/10 INSPECTION
05/26/2010 PLUMBING - ABOVE CEILING N/A Not ready for Inspection IVRS - Inspection :*
1) SUPPORT WATER PIPING FOR RELOCATED WATER HEATER AND TO RESTROOM
2) PROVIDE INSULATION 8' IN + 8' OUT OF WATER HEATER PER 2006 IECC REQUIREMENTS

Completed Inspections

Permit Status: Expired
Permit Number: T10CM01138
Permit Description: TI: RESTAURANT; SUBWAY
Total Completed Inspections - 5
Date Description Inspector Results Comments
05/19/2010 SHEET ROCK NAILING JBURGE Approved IVRS - Inspection :*
1) OK TO TAPE THROUGHOUT
05/19/2010 FRAMING JBURGE Approved IVRS - Inspection :*
1) AS PER PLANS
05/26/2010 BUILDING ABOVE CEILING GDABBS Approved IVRS - Inspection :*
05/27/2010 MECHANICAL - ABOVE CEILING JMILITEL Approved IVRS - Inspection :*
1) FOR FINAL PROVIDE APPROVED MECHANICAL PLAN, PERMITS FOR 2 A/C UNITS INSTALLED WITHOUT PERMITS OR INSPECTIONS
2) UNITS ARE MISSING FRESH AIR INTAKES, WRONG FUSES, WRONG DISCONNECT, CONDENSATE NOT PROPERLY SUPPORTED OR PAINTED WITH LATEX PAINT, IMPROPER WRING METHODS, CANVAS CONNECTOR NOT PROPERLY COVERED, I.D. DATA PLATES WITH PROPER HEAT STRIP AND FUSE ACCORDINGLY
05/27/2010 ELECTRIC - ABOVE CEILING RJIROUDE Approved IVRS - Inspection :*

Documents

File Name Document Type  
001_CS-01.TIF CONSTRPLANS VIEW
002_D-01.TIF CONSTRPLANS VIEW
003_A-00.TIF CONSTRPLANS VIEW
004_A-01.TIF CONSTRPLANS VIEW
005_A-02.TIF CONSTRPLANS VIEW
006_A-03.TIF CONSTRPLANS VIEW
007_A-04.TIF CONSTRPLANS VIEW
008_A-05.TIF CONSTRPLANS VIEW
009_A-06.TIF CONSTRPLANS VIEW
010_A-07.TIF CONSTRPLANS VIEW
011_A-08.TIF CONSTRPLANS VIEW
012_A-09.TIF CONSTRPLANS VIEW
013_MP-01.TIF CONSTRPLANS VIEW
014_MP-02.TIF CONSTRPLANS VIEW
015_E-01.TIF CONSTRPLANS VIEW
016_E-02.TIF CONSTRPLANS VIEW
None DOCUMENTS VIEW