Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Details

Status:
C of o
Type:
COMMERCIAL ALTERATION
Address:
153 S PLUMER AV
Apply Date:
04/20/2010
Applicant:
N/A
Description:
TI & C OF O: ADMIN OFFICE
Contractors:
  • KITTLE DESIGN AND CONSTRUCTION L L C

Permit Reviews

Permit Number - T10CM01057
Permit Status: C of o
Permit Description: TI & C OF O: ADMIN OFFICE
Start Date Submittal Complete Date Status  
04/20/2010 COMMERCIAL TI 04/20/2010 COMPLETED Review Details
04/20/2010 SITE 04/20/2010 COMPLETED Review Details
04/20/2010 COMMERCIAL TI 05/20/2010 COMPLETED Review Details
04/20/2010 SITE 05/20/2010 COMPLETED Review Details
05/20/2010 RESUBMITTAL - TI ALL 06/24/2010 COMPLETED Review Details
05/20/2010 RESUBMITTAL - SITE 06/21/2010 COMPLETED Review Details
06/21/2010 RESUBMITTAL - SITE 06/24/2010 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T10CM01057
Permit Status: C of o
Permit Description: TI & C OF O: ADMIN OFFICE
Total Outstanding Activity Conditions - 1
Date Name
04/20/2010 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Completed Inspections

Permit Status: C of o
Permit Number: T10CM01057
Permit Description: TI & C OF O: ADMIN OFFICE
Total Completed Inspections - 30
Date Description Inspector Results Comments
06/30/2010 PLUMBING - ROUGH, SOIL BBENEDON Approved IVRS - Inspection :*
1) TEST THRU RE-VENT
07/02/2010 PLUMBING - PRE SLAB RLEDONNE Approved IVRS - Inspection :*
07/14/2010 ELECTRIC - INTERMEDIATE RJIROUDE Approved IVRS - Inspection :*
07/27/2010 ROOF NAILING MHENSON Approved IVRS - Inspection :*
08/02/2010 FRAMING MHENSON Approved IVRS - Inspection :*
08/16/2010 FIRE SPKLR - UG, PIPING, HYDRO LTHOMAS Approved
08/25/2010 SHEET ROCK NAILING AQUIROZ Approved IVRS - Inspection :*
09/07/2010 PLUMBING - ABOVE CEILING RLEDONNE Approved IVRS - Inspection :*
1) PROVIDE SUPPORT ON ALL GAS PIPING
2) PROVIDE GAUGE IN 1/10 PSI INCREMENTATIONS FOR FINAL
09/07/2010 PLUMBING - GAS PRESSURE TEST RLEDONNE Approved IVRS - Inspection :*
09/21/2010 MECHANICAL - ABOVE CEILING MRAMBER Approved IVRS - Inspection :*
10/07/2010 PLUMBING - GAS PRESS TEST FNL RLEDONNE Approved IVRS - Inspection :*
10/13/2010 FIREWALL/FIREBARRIER/FIRESTOP JBURGE Approved IVRS - Inspection :*
10/13/2010 BUILDING ABOVE CEILING JBURGE Approved IVRS - Inspection :*
10/13/2010 RIGHT OF WAY - FINAL M.Otero Approved
10/14/2010 NPPO - FINAL MCARREON Approved
10/14/2010 LANDSCAPE - FINAL MCARREON Approved
10/14/2010 ELECTRIC - ABOVE CEILING RHOLLAND Approved IVRS - Inspection :*
10/14/2010 ELECTRIC - UNDERGROUND RHOLLAND Approved IVRS - Inspection :*
10/15/2010 MECHANICAL - FINAL MRAMBER Approved IVRS - Inspection :*
10/15/2010 MECHANICAL - INTERMEDIATE MRAMBER Approved IVRS - Inspection :*
10/19/2010 FIRE SPKLR - FINAL LTHOMAS Approved
10/19/2010 ELECTRIC - FINAL RJIROUDE Approved IVRS - Inspection :*
10/20/2010 PLUMBING - FINAL RLEDONNE Approved IVRS - Inspection :*
10/20/2010 PLUMBING - PROGRESS RLEDONNE Approved IVRS - Inspection :*
10/20/2010 PLUMBING - INTERMEDIATE RLEDONNE Approved IVRS - Inspection :*
10/22/2010 CERTIFICATE OF OCCUPANCY MHENSON Approved IVRS - Inspection :*
10/22/2010 BUILDING - FINAL MHENSON Approved IVRS - Inspection :*
10/22/2010 FIRE - FINAL LTHOMAS Approved
10/27/2010 SIGN - FINAL ACONNOR Approved
10/27/2010 ENGINEERING - FINAL JGREEN Approved Per Malena there were no site changes therefore no "As-built" plans should have been required. The plan set in SIRE is up to date per the inspector.

Documents

File Name Document Type  
C OF O_10-27-2010.TIF CERT OF OCC VIEW
001_COVER.TIF CONSTRPLANS VIEW
002_SP-1.TIF CONSTRPLANS VIEW
003_SP-2.TIF CONSTRPLANS VIEW
004_D-1.TIF CONSTRPLANS VIEW
005_NPPO.TIF CONSTRPLANS VIEW
006_L-1.TIF CONSTRPLANS VIEW
007_L-2.TIF CONSTRPLANS VIEW
008_G-1.TIF CONSTRPLANS VIEW
009_G-2.TIF CONSTRPLANS VIEW
010_G-3.TIF CONSTRPLANS VIEW
011_A1.0.TIF CONSTRPLANS VIEW
012_A2.0.TIF CONSTRPLANS VIEW
013_A2.1.TIF CONSTRPLANS VIEW
014_A2.2.TIF CONSTRPLANS VIEW
015_A3.0.TIF CONSTRPLANS VIEW
016_A3.1.TIF CONSTRPLANS VIEW
017_A4.0.TIF CONSTRPLANS VIEW
018_A5.0.TIF CONSTRPLANS VIEW
019_A6.0.TIF CONSTRPLANS VIEW
020_A7.0.TIF CONSTRPLANS VIEW
021_S.1.TIF CONSTRPLANS VIEW
022_P1.1.TIF CONSTRPLANS VIEW
023_P1.2.TIF CONSTRPLANS VIEW
024_P2.1.TIF CONSTRPLANS VIEW
025_P3.1.TIF CONSTRPLANS VIEW
026_M1.1.TIF CONSTRPLANS VIEW
027_M1.2.TIF CONSTRPLANS VIEW
028_M2.1.TIF CONSTRPLANS VIEW
029_M2.2.TIF CONSTRPLANS VIEW
030_M3.1.TIF CONSTRPLANS VIEW
031_M4.1.TIF CONSTRPLANS VIEW
032_E.1.TIF CONSTRPLANS VIEW
033_E.2.TIF CONSTRPLANS VIEW
034_E.3.TIF CONSTRPLANS VIEW
035_E.4.TIF CONSTRPLANS VIEW
036_E.5.TIF CONSTRPLANS VIEW
None DOCUMENTS VIEW