Permit Number: T10CM01057
Parcel: 12901018L

Address:
153 S PLUMER AV

Review Status: Completed

Review Details: SITE

Permit Number - T10CM01057
Review Name: SITE
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
04/21/2010 BIANCA RAMIREZ ENGINEERING REVIEW Denied DATE: May 5, 2010
SUBJECT: 153 S Plumer Ave
TO: Jim Watson
LOCATION: 153 S Plumer Ave, T14S, R14E, Section 17, Ward 6
REVIEWERS: Bianca Ramirez, CFM
ACTIVITY: T10CM01057 (First Review)


RESUBMITTAL REQUIRED: Site Plan

SUMMARY: Engineering Division of Development Services Department has received and reviewed the proposed site plan for the above referenced property. Engineering Division does not recommend approval of the site plan at this time. Please address the following review comments prior to the next submittal.

Please include a response letter to the comments with the corrected copies of the site plan.
Site Plan:

1. Please provide property description per D.S. 2-02.2.1.A.2.
2. Please label lot bearings for west and northeast property line per D.S. 2-02.2.1.A.5
3. Please provide location, type, size, and height of existing and proposed signage D.S. 2-02.2.1.A.13. Signage should be provided to clearly indicate one way areas.
4. DS Sec.2.02.2.1.A.16: Provide roof drainage arrows and locations of all concentration points. Specifically show roof down spout locations proposed buildings at pedestrian circulation areas. A detail for the dimension of the proposed scuppers that are used for collecting onsite roof drainage at all pedestrian sidewalk is required; refer to City of Tucson details. Any scuppers proposed under the sidewalk will be designed and constructed to convey the 10-year flood flow.
5. D.S. Sec.2-02.2.1.A.17: It appears that cut and fill will not be occurring for the proposal. However, as part of the site submittal requirement estimated cut and fill quantities are required to be indicated on the plans so that it is clear to the inspector that no cut in fill is to be taking place. If not cut and fill is taking place indicate the quantity of zero (0) on the plan. Estimated cut and Fill: Cut = 0 and Fill = 0 will suffice.
6. Please label R.O.W. dimensions as existing or future. If the distance is the same for both the existing and future please indicate accordingly on site plan.
7. Provide the site plan activity number in the bottom right hand corner of each sheet in the lower right hand corner.
8. Show refuse container location, size, and access thereto fully dimensioned per D.S. 2-02.2.1.32 and D.S. 6-01.0.
9. A permit or a private improvement agreement will be necessary for any work performed within the right-of-way. Contact Permits and Codes at (520) 791-5100 for permit information.
10. Add note: "Depress all landscaped areas 6" maximum for water harvesting".
11. Verify that all easement of record have been graphically shown on the plan together with recording docket and page reference per D.S. 2-02.2.1.20.
12. Additional comments may be forthcoming.

If you have any questions, I can be reached at 837-4928 or Bianca.Ramirez@tucsonaz.gov

Bianca C. Ramirez
Engineering Associate
City of Tucson/Development Services Department
201 N. Stone Avenue
P.O. Box 27210
Tucson, Arizona 85726-7210
(520) 837-4928 office
(520) 879-8010 fax
04/23/2010 STEVE SHIELDS ZONING REVIEW Denied PDSD TRANSMITTAL

FROM: Steve Shields
Lead Planner

PROJECT: Aviva Children Services - Office Bldg.
T10CM01057
Site Plan (1st Review)

TRANSMITTAL DATE: April 23, 2010

COMMENTS: Please resubmit revised drawings and a response letter, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed.

1. This site plan was reviewed for compliance with the City of Tucson Development Standards (D.S.) and Land Use Code (LUC) for full code compliance due to a 29.6% expansion of vehicle use area.

2. D.S. 2-02.2.1.A.12 As this site comprises two (2) parcels a parcels combination is required. Provide copies of the approved Pima County Combination Request form and a copy of the recorded Covenant Regarding Development and Use of Real Property prior to approval of the site plan.

3. D.S. 2-02.2.1.A.2 Provide a property description (legal description) on the site plan.

4. D.S. 2-02.2.1.A.8 Zoning acknowledges that the following requested information is shown on sheet G-1 but as it is a requirement of this development standard please provide a radius dimension for the backup spur and the distance from curb to the adjacent wall at the east end of the southern most parking area access lane (PAAL) on sheet D-1.

5. D.S. 2-02.2.1.A.9 Demonstrate on the plan how the requirements of D.S. 2-09.5.1.B A minimum of thirty-six (36) inches will be provided between a bicycle parking space and a perpendicular wall or other obstruction measured from the end of the bicycle rack to the perpendicular wall, see Figure 9.

6. D.S. 2-02.2.1.A.12 Per D.S. 2-08.4.1.C Provide a sidewalk between the two (2) parallel vehicle parking spaces and the north side of the existing building.

7. D.S. 2-02.2.1.A.12 Due to the one-way PAAL shown at the northeast corner of the existing building the two (2) two-way PAALs shown along the north and east side of the building will need to be one-way due to the lack of turn around space. Clearly demonstrate on the plan how the one-way PAALs will be designated, i.e. signage, pavement markings, etc.

8. D.S. 2-02.2.1.A.20 If applicable show all easements of record must be graphically shown on the plan together with recording docket and page reference.

9. D.S. 2-02.2.2.A.1 Revise General Note 5 to reflect only the Gross site area for this proposed project.
10. Depending on how the above comments are addressed addition comments may be forth coming.
If you have any questions about this transmittal, please contact me at Steve.Shields@tucsonaz.gov or (520) 837-4956.

C:\planning\site\t10cm01057

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised site plan and additional requested documents.
04/23/2010 ANDREW CONNOR LANDSCAPE REVIEW Approved
04/26/2010 ANDREW CONNOR NPPO REVIEW Approved
04/27/2010 RONALD BROWN ZONING HC REVIEW Denied SHEET G2
1. Insure that all grades, dimensions etc. match those as the referenced large scale detail shown on sheet G-3.
SHEET G-3
2. Neither ramp at the marked crossing to Plumber Av is compliant with ICC (ANSI 117,1) Section 405.7. Each ramp must have a 5' deep landing at the top and bottom and the may not be in the PAAL.
3. None of the ramp handrails comply with Section 505 and figure 505.10.1
END OF REVIEW
05/06/2010 ROBERT SHERRY PLUMBING-COMMERCIAL REVIEW Approved

Final Status

Task End Date Reviewer's Name Type of Review Description
05/20/2010 CPIERCE1 OUT TO CUSTOMER Completed
05/20/2010 SUE REEVES REJECT SHELF Completed