Permit: T10CM01057

Parcel: 12901018L


Addresses:

153 S PLUMER AV


Inspection Status: Approved

Inspection History: PLUMBING - PROGRESS

Permit Number - T10CM01057

Inspection Description - PLUMBING - PROGRESS

Inspection Status - Approved

Date Description Inspector Results Comments
10/20/2010 PLUMBING - PROGRESS Approved IVRS - Inspection :*
09/22/2010 PLUMBING - PROGRESS Partial Approval IVRS - Inspection :*
1) ALL FLANGES OK
09/20/2010 PLUMBING - PROGRESS Not ready for Inspection IVRS - Inspection :*
1) RP INSTALLS OK, WILL REQUIRE ON IRR ASSEM, ALSO CORRECT DRIP
2) NIBCO NOT LISTED FOR INSIDE PIPE
3) ALSO PROVIDE 100 MAKEUP ON SOLVENT WELD FITTINGS AND PROVIDE A SMOOTH INTERIOR WITH PIPE EVEN WITH TOP OF FLANGES
09/17/2010 PLUMBING - PROGRESS Partial Approval IVRS - Inspection :*
1) FLANGES WEST SIDE OK
2) KEEP OPEN PIPES CAPPED FOR SAFETY
09/15/2010 PLUMBING - PROGRESS Not ready for Inspection IVRS - Inspection :*
1) 316.3.1, 316.3.2 AND 704.4.5
08/20/2010 PLUMBING - PROGRESS Partial Approval IVRS - Inspection :*
1) YARDWATER STUB FROM BLDG THRU CURB 1' 1 1/2 PVC WITH TRACER WIRE
08/19/2010 PLUMBING - PROGRESS Not ready for Inspection IVRS - Inspection :*
1) COMPLETE INSTALL AND PROVIDE TRACER WIRE
07/29/2010 PLUMBING - PROGRESS Partial Approval IVRS - Inspection :*
1) ICE MAKER BOXES OK ROOM #16
07/28/2010 PLUMBING - PROGRESS Not ready for Inspection IVRS - Inspection :*
07/27/2010 PLUMBING - PROGRESS Partial Approval IVRS - Inspection :*
1) COMPLETE WATER PIPING TO ICE MAKER BOX ON WEST SIDE OF BLDG IN ROOM #6 AND INSULATE
07/26/2010 PLUMBING - PROGRESS Partial Approval IVRS - Inspection :*
1) MEN 30 PLUS WOMEN 31 & P-SH IN WALL PIPING TEST OK
2) MEN 8 & WOMEN 7-ABS IN WALL & THRU ROOF TEST OK
3) ROOM 6 SOUTH WALL SINK P-7H & ICE MAKER BOX COPPER STUB UP WALL ABS THRU ROOF TEST OK
4) HOSE BIB ON SOUTH WEST SIDE OF BLDG STUB UP THRU WALL TEST OK (ONLY)