RELOCATE & REPL WATER HEATER TO CARPORT

Permit Reviews

Permit Number - T09PL01739
Permit Status: Final
Permit Description: RELOCATE & REPL WATER HEATER TO CARPORT
Start Date Submittal Complete Date Status  
10/23/2009 PLUMBING 10/23/2009 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T09PL01739
Permit Status: Final
Permit Description: RELOCATE & REPL WATER HEATER TO CARPORT
Total Outstanding Activity Conditions - 1
Date Name
10/23/2009 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Completed Inspections

Permit Status: Final
Permit Number: T09PL01739
Permit Description: RELOCATE & REPL WATER HEATER TO CARPORT
Total Completed Inspections - 3
Date Description Inspector Results Comments
10/29/2009 PLUMBING - GAS PRESSURE TEST BBENEDON Approved IVRS - Inspection :
See detailed listing on site.| 999*
1) NEED TO SEE THE PIPING CONNECTIONS COVERED INSIDE HOME
2) CORRECT LEAKING T & P RELIEF VALVE
3) WILL ACCEPT MAKE-SHIFT PLATFORM IF YOU INSTALL A WATER HEATER PAN AND DIRECT DRAIN AWAY FROM WOOD
4) PROVIDE SEDIMENT TRAP
5) FOR GAS RECONNECT, CORRECT PIPING ON ROOF; SUPPORTS, FLASHINGS, ETC...PROVIDE ACCESS (LADDER)
6) REMOVE UN-APPROVED PIPING AT WEST SIDE
7) PROVIDE A GAUGE WITH 1/10 PSI INCREMENTATIONS
8) PROVIDE A MINIMUM 10 PSI, (9.5 ON 30 PSI GAUGE)
9) CORRECT LEAKS
10/29/2009 PLUMBING - FINAL BBENEDON Approved IVRS - Inspection :*
03/02/2010 PERMIT FINALED JWEATHER Approved