Permit: T09PL01739

Parcel: 136332760


Addresses:

9049 E ARBOR ST


Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Permit Number - T09PL01739

Inspection Description - PLUMBING - FINAL

Inspection Status - Approved

Date Description Inspector Results Comments
03/01/2010 PLUMBING - FINAL Approved IVRS - Inspection :*
02/26/2010 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
1) PRESSURE GAUGE FOR GAS PIPING TEST IS BAD
2) PROVIDE GOOD WORKING GAUGE FOR GAS PRESSSURE TEST
02/24/2010 PLUMBING - FINAL Denied IVRS - Inspection :
1. PROVIDE MINIMUM OF 10 PSI TEST ON ENTIRE GAS SYSTEM AT TIME OF INSPECTION.
2. TEST TO BE INTO HEARTH OF FIREPLACE, LEAVE LOG LIGHTER KEY TO VERIFY VALVE IS ON
3. RELOCATED WATER HEATER REQUIRES SOME FORM OF PROTECTION FROM COLLISION WITH CAR IN NEW GARAGE
4. PROVIDE BONDING OF BUILDING GAS PIPING.
10/29/2009 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
10/28/2009 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
10/26/2009 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*