Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - GAS PRESSURE TEST
Permit Number - T09PL01739
Inspection Description - PLUMBING - GAS PRESSURE TEST
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 03/01/2010 | PLUMBING - GAS PRESSURE TEST | Approved | IVRS - Inspection :* | |
| 02/24/2010 | PLUMBING - GAS PRESSURE TEST | Denied | IVRS - Inspection : 1. PROVIDE MINIMUM OF 10 PSI TEST ON ENTIRE GAS SYSTEM AT TIME OF INSPECTION. 2. TEST TO BE INTO HEARTH OF FIREPLACE, LEAVE LOG LIGHTER KEY TO VERIFY VALVE IS ON 3. RELOCATED WATER HEATER REQUIRES SOME FORM OF PROTECTION FROM COLLISION WITH CAR IN NEW GARAGE 4. PROVIDE BONDING OF BUILDING GAS PIPING. |
|
| 10/29/2009 | PLUMBING - GAS PRESSURE TEST | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) NEED TO SEE THE PIPING CONNECTIONS COVERED INSIDE HOME 2) CORRECT LEAKING T & P RELIEF VALVE 3) WILL ACCEPT MAKE-SHIFT PLATFORM IF YOU INSTALL A WATER HEATER PAN AND DIRECT DRAIN AWAY FROM WOOD 4) PROVIDE SEDIMENT TRAP 5) FOR GAS RECONNECT, CORRECT PIPING ON ROOF; SUPPORTS, FLASHINGS, ETC...PROVIDE ACCESS (LADDER) 6) REMOVE UN-APPROVED PIPING AT WEST SIDE 7) PROVIDE A GAUGE WITH 1/10 PSI INCREMENTATIONS 8) PROVIDE A MINIMUM 10 PSI, (9.5 ON 30 PSI GAUGE) 9) CORRECT LEAKS |
|
| 10/28/2009 | PLUMBING - GAS PRESSURE TEST | Not ready for Inspection | IVRS - Inspection :* 1) CONTINUED "NOT READYS" MAY RESULT IN A REINSPECTION FEE |
|
| 10/26/2009 | PLUMBING - GAS PRESSURE TEST | Not ready for Inspection | IVRS - Inspection :* |