Permit: T09PL01739

Parcel: 136332760


Addresses:

9049 E ARBOR ST


Inspection Status: Approved

Inspection History: PLUMBING - GAS PRESSURE TEST

Permit Number - T09PL01739

Inspection Description - PLUMBING - GAS PRESSURE TEST

Inspection Status - Approved

Date Description Inspector Results Comments
03/01/2010 PLUMBING - GAS PRESSURE TEST Approved IVRS - Inspection :*
02/24/2010 PLUMBING - GAS PRESSURE TEST Denied IVRS - Inspection :
1. PROVIDE MINIMUM OF 10 PSI TEST ON ENTIRE GAS SYSTEM AT TIME OF INSPECTION.
2. TEST TO BE INTO HEARTH OF FIREPLACE, LEAVE LOG LIGHTER KEY TO VERIFY VALVE IS ON
3. RELOCATED WATER HEATER REQUIRES SOME FORM OF PROTECTION FROM COLLISION WITH CAR IN NEW GARAGE
4. PROVIDE BONDING OF BUILDING GAS PIPING.
10/29/2009 PLUMBING - GAS PRESSURE TEST Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) NEED TO SEE THE PIPING CONNECTIONS COVERED INSIDE HOME
2) CORRECT LEAKING T & P RELIEF VALVE
3) WILL ACCEPT MAKE-SHIFT PLATFORM IF YOU INSTALL A WATER HEATER PAN AND DIRECT DRAIN AWAY FROM WOOD
4) PROVIDE SEDIMENT TRAP
5) FOR GAS RECONNECT, CORRECT PIPING ON ROOF; SUPPORTS, FLASHINGS, ETC...PROVIDE ACCESS (LADDER)
6) REMOVE UN-APPROVED PIPING AT WEST SIDE
7) PROVIDE A GAUGE WITH 1/10 PSI INCREMENTATIONS
8) PROVIDE A MINIMUM 10 PSI, (9.5 ON 30 PSI GAUGE)
9) CORRECT LEAKS
10/28/2009 PLUMBING - GAS PRESSURE TEST Not ready for Inspection IVRS - Inspection :*
1) CONTINUED "NOT READYS" MAY RESULT IN A REINSPECTION FEE
10/26/2009 PLUMBING - GAS PRESSURE TEST Not ready for Inspection IVRS - Inspection :*