Permit: T09OT00192
Permit Details
Status:
Expired
Type:
COMMERCIAL OTHER
Address:
9431 E 22ND ST #137
Address NEW:
9431 E 22ND ST #137
Apply Date:
01/30/2009
Applicant:
CARL SORELL
Description:
C OF O: RESTAURANT SUITES 137 AND 139
Permit Reviews
Permit Number - T09OT00192
Permit Status: Expired
Permit Description: C OF O: RESTAURANT SUITES 137 AND 139
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 01/30/2009 | C OF O | 01/30/2009 | COMPLETED |
Outstanding Inspections
Permit Status: Expired
Permit Number: T09OT00192
Permite Description: C OF O: RESTAURANT SUITES 137 AND 139
Total Outstanding Inspections - 2
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 02/23/2009 | FIRE - FINAL | N/A | Partial Approval | TEMP C OF O ONLY. NEED TO INSTALL FIRE EXTINGUISHER SYSTEM TO HOOD FOR CONVEYOR PIZZA OVEN. |
| 02/24/2009 | MECHANICAL - HOODS | N/A | Denied | IVRS - Inspection : See detailed listing on site.| 999* THE HOOD WOULD MEET TYPE I REQUIREMENTS IF IT HAD A FILTER RACK, 16GA. WELDED DUCT W/2 LAYERS FIRE WRAP, A TYPE I FAN, FIRE SUPPRESSION SYSTEM, HEAT SENSOR |
Completed Inspections
Permit Status: Expired
Permit Number: T09OT00192
Permit Description: C OF O: RESTAURANT SUITES 137 AND 139
Total Completed Inspections - 1
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 02/20/2009 | CERTIFICATE OF OCCUPANCY | GDABBS | Approved | IVRS - Inspection :* |