Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Details

Status:
Si_xpire
Type:
SINGLE FAMILY ADDITION
Address:
960 S PANTANO RD
Address NEW:
960 S PANTANO RD
Apply Date:
11/25/2009
Applicant:
N/A
Description:
SOLAR WATER HEATER
Contractors:
  • RUSSETT SERVICE CORPORATION, *C

Permit Reviews

Permit Number - T09CM03116
Permit Status: Si_xpire
Permit Description: SOLAR WATER HEATER
Start Date Submittal Complete Date Status  
02/12/2010 REVISION - - 1ST 03/04/2010 COMPLETED Review Details
11/25/2009 RESIDENTIAL BLDG/ZONING-WALKTHRU 11/25/2009 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T09CM03116
Permit Status: Si_xpire
Permit Description: SOLAR WATER HEATER
Total Outstanding Activity Conditions - 3
Date Name
11/25/2009 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.
11/25/2009 SPECIAL INSPECTION FORMS AND REPORTS REQUIRED PRIOR TO ISSUANCE OF A CERTIFICATE OF OCCUPANCY.
11/25/2009 SPECIAL INSPECTION FOR EXPANSION ANCHORS IS REQUIRED.

Completed Inspections

Permit Status: Si_xpire
Permit Number: T09CM03116
Permit Description: SOLAR WATER HEATER
Total Completed Inspections - 2
Date Description Inspector Results Comments
12/21/2009 PLUMBING - FINAL RRICH Approved IVRS - Inspection :
See detailed listing on site.| 999*
1) PROVIDE CORRECT COLOR WIRE FOR NEW CIRCUIT TO WATER HEATER
2) LOCATE DISCONNECT WITH CORRECT CLEARANCE PER 2006 NEC REQUIREMENTS
3) PROPERLY SECURE UPPER PIPING FOR DRAIN BACK TANK
4) IF FITTINGS ARE USED ON ROOF TOP THEY ARE TO BE UV LISTED FOR EXPOSURE TO SUNLIGHT AS IS TUBING
5) WHERE IS TEMPERING VALVE PER PLAN TO AVOID SCALDING ?
12/21/2009 PLUMBING - INTERMEDIATE RRICH Approved IVRS - Inspection :
See detailed listing on site.| 999*
1) SUPPORT PANEL AND ROOF TOP PIPING MINIMUM 1 1/2" ABOVE ROOF SURFACE
2) PROVIDE UV LISTED ROOF TOP PIPING
3) INSULATION TO BE SEALED PROPERLY WITH NO GAPS AND HAVE UV PROTECTION FROM SUNLIGHT
4) PROPERLY REPAIR HOLES IN ROOF FROM SUPPORTS DIRECTLY THRU ROOF SURFACE WITHOUT ANY FORM OF WEATHER PROOF