Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: T09CM03116

Parcel: 134142540


Addresses:

960 S PANTANO RD

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
03/30/2010 PLUMBING - FINAL Approved IVRS - Inspection :*
02/08/2010 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
1) PLEASE PROVIDE THE SRCC OG-300 PLAN THAT IS CITY OF TUCSON APPROVED FOR THIS SITE SPECIAL INSTALLATION (PIPING DIAGRAM)
12/21/2009 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) PROVIDE CORRECT COLOR WIRE FOR NEW CIRCUIT TO WATER HEATER
2) LOCATE DISCONNECT WITH CORRECT CLEARANCE PER 2006 NEC REQUIREMENTS
3) PROPERLY SECURE UPPER PIPING FOR DRAIN BACK TANK
4) IF FITTINGS ARE USED ON ROOF TOP THEY ARE TO BE UV LISTED FOR EXPOSURE TO SUNLIGHT AS IS TUBING
5) WHERE IS TEMPERING VALVE PER PLAN TO AVOID SCALDING ?