Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Details

Status:
Final
Type:
COMMERCIAL OTHER
Apply Date:
11/06/2009
Applicant:
N/A
Description:
FOUNDATION ONLY
Contractors:
  • MCMANUS CONSTRUCTION

Permit Reviews

Permit Number - T09CM02954
Permit Status: Final
Permit Description: FOUNDATION ONLY
Start Date Submittal Complete Date Status  
11/06/2009 OTHER 11/06/2009 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T09CM02954
Permit Status: Final
Permit Description: FOUNDATION ONLY
Total Outstanding Activity Conditions - 1
Date Name
11/06/2009 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Completed Inspections

Permit Status: Final
Permit Number: T09CM02954
Permit Description: FOUNDATION ONLY
Total Completed Inspections - 11
Date Description Inspector Results Comments
11/06/2009 ELECTRIC - UFER MHENSON Approved 1) APPROVED SHEET NOT ON SITE
2) OBSERVATION ONLY 20' OF 3 OF CLAMPED AT BOTH ENDS WITH APPROVED CLAMPS TO FULL LENGTH PIECES OF REBAR
11/17/2009 STEM WALL/RETAINING WALL MHENSON Approved IVRS - Inspection :*
1) ELEVATOR STEM OK WITH SPECIAL COMPLIANT INSPECTION
11/23/2009 ELECTRIC - UNDERGROUND RHOLLAND Approved IVRS - Inspection :*
1) OK PVC CONDUITS UNDER SLAB
12/16/2009 PLUMBING - ROUGH, SOIL RLEDONNE Approved IVRS - Inspection :*
1) PER HIGHLIGHT ON PAGE P1 ON APPROVED PLANS
12/23/2009 EXCAVATION/LAYOUT REBAR & ZON MHENSON Approved IVRS - Inspection :*
1) 8-F3 EXT COLUMN FOOTINGS, 3 PLANTER FOOTINGS, 1-F2 SCREEN WALL FOOTING AND RESTRAINING WALL FOOTING
2) TERRACON SPECIAL INSPECTED
12/30/2009 REINFORCED MASONRY PRE-GROUT MHENSON Approved IVRS - Inspection :*
1) PLANTERS COMPLETE
04/15/2010 PLUMBING - PRE SLAB RRICH Approved IVRS - Inspection :*
04/15/2010 BUILDING PRE-SLAB MHENSON Approved IVRS - Inspection :*
04/16/2010 PLUMBING - FINAL RLEDONNE Approved
04/16/2010 PLUMBING - SEWER HCS CONNECT RLEDONNE Approved
04/16/2010 PLUMBING - YARD WTR LINE/TEST RLEDONNE Approved

Documents

File Name Document Type  
001_C1.TIF CONSTRPLANS VIEW
002_C2.TIF CONSTRPLANS VIEW
003_S1.0.TIF CONSTRPLANS VIEW
004_S1.1.TIF CONSTRPLANS VIEW
005_S1.2.TIF CONSTRPLANS VIEW
006_S1.3.TIF CONSTRPLANS VIEW
007_S1.4.TIF CONSTRPLANS VIEW
008_S1.5.TIF CONSTRPLANS VIEW
009_S2.0.TIF CONSTRPLANS VIEW
010_S3.0.TIF CONSTRPLANS VIEW
011_S3.1.TIF CONSTRPLANS VIEW
012_S4.0.TIF CONSTRPLANS VIEW
013_S5.0.TIF CONSTRPLANS VIEW
014_S5.1.TIF CONSTRPLANS VIEW
015_S5.2.TIF CONSTRPLANS VIEW
016_P1.TIF CONSTRPLANS VIEW
017_E0.TIF CONSTRPLANS VIEW
018_E1.TIF CONSTRPLANS VIEW
None DOCUMENTS VIEW