Permit: T09CM01370
Permit Details
Apply Date:
05/29/2009
Applicant:
N/A
Description:
RESTAURANT:NEW TACO BELL
Architects:
- LOOKER, JEFF ANTHONY
Contractors:
- HAWORTH CORPORATION , THE
Permit Reviews
Permit Number - T09CM01370
Permit Status: C of o
Permit Description: RESTAURANT:NEW TACO BELL
Start Date | Submittal | Complete Date | Status |
---|---|---|---|
05/29/2009 | PLANS OK TO SUBMIT - COMM | 05/29/2009 | COMPLETED |
05/29/2009 | COMMERCIAL NEW | 08/13/2009 | COMPLETED |
08/19/2009 | RESUBMITTAL | 08/27/2009 | COMPLETED |
08/27/2009 | RESUBMITTAL - TI ALL | 10/06/2009 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T09CM01370
Permit Status: C of o
Permit Description: RESTAURANT:NEW TACO BELL
Total Outstanding Activity Conditions - 1
Date | Name |
---|---|
05/29/2009 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: C of o
Permit Number: T09CM01370
Permit Description: RESTAURANT:NEW TACO BELL
Total Completed Inspections - 44
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
10/06/2009 | BUILDING PRE-SLAB | JBURGE | Approved | 1) OK TO POUR, NO CONTROL JOINT AS PER ARCHITECT DATED 10/09/09 |
10/06/2009 | PLUMBING - PRE SLAB | RLEDONNE | Approved | IVRS - Inspection :* |
10/13/2009 | ELECTRIC - INTERMEDIATE | RMORENO | Approved | IVRS - Inspection :* 1) ALL WALLS IN BLDG OK |
10/14/2009 | FRAMING | JBURGE | Approved | IVRS - Inspection :* 1) OK TO SHEETROCK; ELECTRIC AND PLUMBING INTER: COMPLETE |
10/15/2009 | PLUMBING - GAS PRESSURE TEST | RLEDONNE | Approved | IVRS - Inspection :* |
10/15/2009 | PLUMBING - ROOF DRAINS | RLEDONNE | Approved | IVRS - Inspection :* |
10/16/2009 | SHEET ROCK NAILING | JBURGE | Approved | IVRS - Inspection :* 1) OK TO TAPE THROUGHOUT |
10/26/2009 | PLUMBING - SEWER HCS CONNECT | RLEDONNE | Approved | IVRS - Inspection :* |
10/27/2009 | EXCAVATION/LAYOUT REBAR & ZON | JBURGE | Approved | IVRS - Inspection :* 1) MENU BOARD, SPEAKER POST, CLEARANCE BAR CAISSON FOOTINGS; DETAILS 331,32,30-OK TO POUR FOOTINGS |
10/27/2009 | TEP CLEARANCE - AM | JWEATHER | Approved | TEC CLEARED PER R. MORENO |
10/30/2009 | MECHANICAL - HOODS | JMILITEL | Approved | IVRS - Inspection :* |
10/30/2009 | MECHANICAL - ABOVE CEILING | JMILITEL | Approved | IVRS - Inspection :* 1) OK FOR CEILING TILES 2) CONDENSATE FROM RTU-2 CANNOT BE REDUCED FROM THE SIZE OF THE OUTLET ON UNIT 307.1 2006 I.M.C. 3) DISCHARGE FROM EXHAUST FAN TO BE EQUAL TO OR HIGHER THAN PARAPET WALL |
10/30/2009 | ELECTRIC - ABOVE CEILING | RMORENO | Approved | IVRS - Inspection :* 1) CEILING IN BLDG OK |
10/30/2009 | BUILDING ABOVE CEILING | JBURGE | Approved | IVRS - Inspection :* 1) OK TO SET CEILING TILES |
10/30/2009 | ROOF NAILING | JBURGE | Approved | IVRS - Inspection :* |
10/30/2009 | REINFORCED MASONRY PRE-GROUT | JBURGE | Approved | IVRS - Inspection :* |
10/30/2009 | STEM WALL/RETAINING WALL | JBURGE | Approved | IVRS - Inspection :* |
10/30/2009 | ELECTRIC - UNDERGROUND | RMORENO | Approved | IVRS - Inspection :* |
10/30/2009 | ELECTRIC - UFER | RMORENO | Approved | IVRS - Inspection :* |
10/30/2009 | ELECTRIC - CABLE DROP | RMORENO | Approved | IVRS - Inspection :* |
11/06/2009 | ELECTRIC - FINAL | RMORENO | Approved | IVRS - Inspection :* 1) LIGHTING, POWER, EXITS, EM LIGHTS, ROOF A/C AND EXHAUST FAN |
11/09/2009 | PLUMBING - GAS PRESS TEST FNL | BBENEDON | Approved | IVRS - Inspection :* |
11/09/2009 | PLUMBING - INTERMEDIATE | BBENEDON | Approved | IVRS - Inspection :* |
11/09/2009 | PLUMBING - YARD WTR LINE/TEST | BBENEDON | Approved | IVRS - Inspection :* |
11/09/2009 | PLUMBING - ROUGH, SOIL | BBENEDON | Approved | IVRS - Inspection :* |
11/09/2009 | BUILDING - PROGRESS | JBURGE | Approved | IVRS - Inspection :* |
11/10/2009 | MECHANICAL - FINAL | JMILITEL | Approved | IVRS - Inspection :* 1) AIR BALANCE OK 2) OK FOR FINAL |
11/10/2009 | MECHANICAL - INTERMEDIATE | JMILITEL | Approved | IVRS - Inspection :* |
11/10/2009 | ENGINEERING - FINAL | DROBERTS | Approved | |
11/10/2009 | FIRE - KITCHEN EXH HOOD FINAL | DRamirez | Approved | Approved 11.10.09. |
11/10/2009 | FIRE - FINAL | DRamirez | Approved | Approved 11/10/09. |
11/10/2009 | ELECTRIC - OUTDOOR LIGHTING | RMORENO | Approved | IVRS - Inspection :* |
11/14/2009 | BUILDING - FINAL | JBURGE | Approved | IVRS - Inspection :* 1) ALL TRADES AND FIRE FINALS ARE COMPLETE 2) AFTER HOURS INSPECTION-CHECK #02794 AT $300 GIVEN TO PLUMBING INSPECTOR |
11/14/2009 | PLUMBING - FINAL | RLEDONNE | Approved | IVRS - Inspection :* |
11/14/2009 | PLUMBING - PROGRESS | RLEDONNE | Approved | IVRS - Inspection :* |
11/16/2009 | NPPO - FINAL | ACONNOR | Approved | |
11/16/2009 | LANDSCAPE - FINAL | ACONNOR | Approved | |
11/16/2009 | RIGHT OF WAY - FINAL | PWHIDDON | Approved | |
11/16/2009 | EXT METAL CLIPS/EXT SHEATHING | JBURGE | Approved | |
11/16/2009 | PLUMBING - ABOVE CEILING | RLEDONNE | Approved | |
11/16/2009 | ELECTRIC - TEMP POWER FOR TEST | RMORENO | Approved | |
11/16/2009 | OUTDOOR LIGHTING FINAL | RMORENO | Approved | |
11/16/2009 | HEALTH DEPT - FINAL 724-7908 | LGERINGER | Approved | |
11/18/2009 | SIGN - FINAL | JYBARRA | Approved |