Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit: T09BU00399
Permit Details
Apply Date:
03/18/2009
Applicant:
N/A
Description:
GRADING QuikTrip 1493 S Kolb
Contractors:
- BARKER MORRISSEY CONTRACTING INC **C
Permit Reviews
Permit Number - T09BU00399
Permit Status: Final
Permit Description: GRADING QuikTrip 1493 S Kolb
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 03/18/2009 | PLANS OK TO SUBMIT - GRADING | 12/18/2009 | COMPLETED |
| 12/18/2009 | RESUBMITTAL - GRADING | 02/12/2010 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T09BU00399
Permit Status: Final
Permit Description: GRADING QuikTrip 1493 S Kolb
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 03/18/2009 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: Final
Permit Number: T09BU00399
Permit Description: GRADING QuikTrip 1493 S Kolb
Total Completed Inspections - 11
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 02/18/2010 | ENGINEERING PRE-CONSTRUCTION | MRUSSO | Approved | MET WITH SUPERINTENDENT ON SITE, DISCUSSED STORM WATER PLAN AND GRADING PLAN. CONTRACTOR IN PROCESS OF INSTALLING SEDIMENT CONTROLS |
| 02/25/2010 | STORMWATER INSTALL OF CONTROLS | MRUSSO | Approved | SEDIMENT CONTROLS HAVE BEEN INSTALLED AT PERIMETER. A STABILIZED CONSTRUCTION ENTRANCE HAS BEEN INSTALLED. MAINTAIN CONTROLS THROUGHOUT CONSTRUCTION PER YOUR PLAN. SWEEP UP TRACKING OFF OF PUBLIC ROADWAYS ROUTINELY |
| 06/11/2010 | GRADING - CHECK FOR ACTIVITY | MRUSSO | Approved | |
| 06/11/2010 | STORMWATER FOLLOW-UP INSP | MRUSSO | Approved | MINOR CHANGE TO SIDEWALK LOCATION FOR PED ACCESS FROM STREET TO BLDG, ENSURE RUN SLOPE NO GREATER THAN 5%. SITE WORK APPROXIMATELY 75% COMPLETE, SITE IS STABILIZED, LANDSCAPE 80% DONE. NO OTHER CHANGES OR CONCERNS WITH APPROVED GRADING PLAN. PROVIDE RET/DET, DRAINAGE CERT STATEMENT FROM THE ENGINEER OF RECORD FOR FINAL. |
| 06/15/2010 | GRADING - TIER REV | MRUSSO | Approved | |
| 06/15/2010 | LANDSCAPE INSPECTION | MRUSSO | Approved | MISSING 1 -15 GAL MESQUITE ALONG KOLB RD FRONTAGE CONTRACTOR MUST INSTALL MOISTURE (RAIN) SENSORS PER APPROVED PLAN. |
| 06/15/2010 | STORMWATER FINAL INSPECTION | MRUSSO | Approved | SITE HAS BEEN 100% STABILIZED |
| 06/15/2010 | GRADING - INTERMEDIATE | MRUSSO | Approved | |
| 06/25/2010 | GRADING - FINAL | MRUSSO | Approved | |
| 10/20/2010 | NPPO PRE PERMIT INSPECTION | JFEMLING | Approved | Approved |
| 05/24/2019 | GRADING - REBAR | RLEDONNE | Approved |