Permit: T08CM03397
Permit Details
Apply Date:
10/16/2008
Applicant:
N/A
Description:
TI:OFFICE
Architects:
- QUIHUIS, DANNY XAVIER
Contractors:
- BARKER MORRISSEY CONTRACTING INC **C
Permit Reviews
Permit Number - T08CM03397
Permit Status: C of o
Permit Description: TI:OFFICE
Start Date | Submittal | Complete Date | Status |
---|---|---|---|
10/16/2008 | PLANS OK TO SUBMIT - 3RD PARTY | 10/20/2008 | COMPLETED |
10/20/2008 | 3RD PARTY REVIEW-COMMERCIAL TI | 11/14/2008 | COMPLETED |
11/14/2008 | POST 3RD PARTY REVIEW | 11/17/2008 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T08CM03397
Permit Status: C of o
Permit Description: TI:OFFICE
Total Outstanding Activity Conditions - 1
Date | Name |
---|---|
10/16/2008 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: C of o
Permit Number: T08CM03397
Permit Description: TI:OFFICE
Total Completed Inspections - 28
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
11/26/2008 | PLUMBING - PROGRESS | RMYERS | Approved | |
11/26/2008 | PLUMBING - INTERMEDIATE | RMYERS | Approved | |
11/26/2008 | PLUMBING - ROUGH, SOIL | RMYERS | Approved | |
12/09/2008 | PLUMBING - ABOVE CEILING | BBENEDON | Approved | IVRS - Inspection :* WESTERN WATER TECH. INJECTED 75PPM AT 6 LOCATIONS ON 12/8 SAMPLES TAKEN ON 12/9 WILL PROVIDE TEST REPORT - LETTER RECEIVED FOR DELETION OF FD's IN RMS. 506, 606 AND 615 PER DANNY QUIHUIS (ARCHITECT) |
12/09/2008 | SHEET ROCK NAILING | AQUIROZ | Approved | IVRS - Inspection :* WEST HALF 5TH FLOOR |
12/09/2008 | FRAMING | AQUIROZ | Approved | IVRS - Inspection :* |
12/18/2008 | BUILDING ABOVE CEILING | AQUIROZ | Approved | IVRS - Inspection :* 5TH FLOOR |
12/22/2008 | MECHANICAL - INTERMEDIATE | MRAMBER | Approved | IVRS - Inspection :* COL. 7 NORTH TO 8 SOUTH TO WEST END OF 5TH FLOOR OK FOR TILES MECH. ONLY |
12/22/2008 | ELECTRIC - INTERMEDIATE | RHOLLAND | Approved | IVRS - Inspection :* 1. SECURE VDV CABLING UPON EXITING OF CABLE TRAY 2. SUPPORT VDV CABLING AS PER 725.24, 800.24, 300.11, 725.3, 800.3 OK 2X4 LAY-INS 5 WEST 1/2 OK BORDERS ONLY 5 WEST 1/2 |
12/22/2008 | MECHANICAL - ABOVE CEILING | MRAMBER | Approved | IVRS - Inspection :* |
12/22/2008 | ELECTRIC - PROGRESS | RHOLLAND | Approved | IVRS - Inspection :* |
12/31/2008 | MECHANICAL - PROGRESS | MRAMBER | Approved | IVRS - Inspection :* 1) 5TH FLOOR OK FOR TILES |
12/31/2008 | ELECTRIC - ABOVE CEILING | RHOLLAND | Approved | IVRS - Inspection :* 5TH FLOOR: 1) DISCONNECTS TO A/C IN AN UNSAFE MOUNTING CONDITIONS 2) CLOSE OPENINGS TO BOXES WITH LIVE CIRCUITS 3) CAP UNUSED RELOC BLOCKS 4) CAP UNUSED CONDUITS 5) SUPPORT WIRES NEEDED FOR EXIT SIGNS 6) SUPPORT RELOCK WIRING PER APPLICABLE CODES 7) FINISH VDV CABELING 8) OK TO TILE EXCEPT AREAS NOTED 6TH FLOOR: 1) CHECK VDV CABELING THRU ACCESS OPENINGS 2) OK HARD LID LOBBY |
12/31/2008 | FIRE SPKLR - FINAL | LTHOMAS | Approved | |
01/20/2009 | FIRE - FINAL | LTHOMAS | Approved | |
01/21/2009 | PLUMBING - FINAL | RMYERS | Approved | IVRS - Inspection :* |
01/26/2009 | SIGN - FINAL | JYBARRA | Approved | IVRS - Inspection :* |
01/26/2009 | NPPO - FINAL | ACONNOR | Approved | N/A |
01/26/2009 | LANDSCAPE - FINAL | ACONNOR | Approved | N/A |
01/27/2009 | RIGHT OF WAY - FINAL | MOTERO | Approved | |
01/29/2009 | MECHANICAL - FINAL | JMILITEL | Approved | IVRS - Inspection :* |
01/30/2009 | BUILDING - PROGRESS | AQUIROZ | Approved | IVRS - Inspection :* |
02/04/2009 | ELECTRIC - RECONNECT | RHOLLAND | Approved | IVRS - Inspection :* |
02/04/2009 | ELECTRIC - CONSTRUCTION POWER | RHOLLAND | Approved | IVRS - Inspection :* |
02/04/2009 | ENGINEERING - FINAL | LHANLY | Approved | THIS INSPECTION WAS SCHEDULED 1-26-09 BUT NO RESULTS WERE ENTERED. NO WORK AT THIS SITE OCCURED ON THE EXTERIOR OF THE BUILDING. EXISTING CONDITIONS MAINTAINED. |
02/04/2009 | BUILDING - FINAL | LHANLY | Approved | |
02/05/2009 | ELECTRIC - FINAL | LHANLY | Approved | CONTRACTURAL WORK ON THIS PERMIT COMPLETE. NEC ARTICLE 240.33 ALLOWS FOR OTHER THAN VERTICAL MOUNTING OF DISCONNECTS WHEN IMPRACTIABLE. PER MANUFACTURER OF EQUIPMENT, AND AZ REGISTERED ENGINEER THE CIELING MOUNT OF THE G.E. "TH" DISCONNECTS IS SUITABLE. |
02/09/2009 | PERMIT FINALED | LJACKSON | Approved |