Permit Details

Status:
C of o
Type:
COMMERCIAL ALTERATION
Apply Date:
10/16/2008
Applicant:
N/A
Description:
TI:OFFICE
Architects:
  • QUIHUIS, DANNY XAVIER
Contractors:
  • BARKER MORRISSEY CONTRACTING INC **C

Permit Reviews

Permit Number - T08CM03397
Permit Status: C of o
Permit Description: TI:OFFICE
Start Date Submittal Complete Date Status  
10/16/2008 PLANS OK TO SUBMIT - 3RD PARTY 10/20/2008 COMPLETED Review Details
10/20/2008 3RD PARTY REVIEW-COMMERCIAL TI 11/14/2008 COMPLETED Review Details
11/14/2008 POST 3RD PARTY REVIEW 11/17/2008 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T08CM03397
Permit Status: C of o
Permit Description: TI:OFFICE
Total Outstanding Activity Conditions - 1
Date Name
10/16/2008 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Completed Inspections

Permit Status: C of o
Permit Number: T08CM03397
Permit Description: TI:OFFICE
Total Completed Inspections - 28
Date Description Inspector Results Comments
11/26/2008 PLUMBING - PROGRESS RMYERS Approved
11/26/2008 PLUMBING - INTERMEDIATE RMYERS Approved
11/26/2008 PLUMBING - ROUGH, SOIL RMYERS Approved
12/09/2008 PLUMBING - ABOVE CEILING BBENEDON Approved IVRS - Inspection :*
WESTERN WATER TECH.
INJECTED 75PPM AT 6 LOCATIONS ON 12/8
SAMPLES TAKEN ON 12/9 WILL PROVIDE TEST REPORT
- LETTER RECEIVED FOR DELETION OF FD's IN RMS. 506, 606 AND 615 PER DANNY QUIHUIS (ARCHITECT)
12/09/2008 SHEET ROCK NAILING AQUIROZ Approved IVRS - Inspection :*
WEST HALF 5TH FLOOR
12/09/2008 FRAMING AQUIROZ Approved IVRS - Inspection :*
12/18/2008 BUILDING ABOVE CEILING AQUIROZ Approved IVRS - Inspection :*
5TH FLOOR
12/22/2008 MECHANICAL - INTERMEDIATE MRAMBER Approved IVRS - Inspection :*
COL. 7 NORTH TO 8 SOUTH TO WEST END
OF 5TH FLOOR OK FOR TILES MECH. ONLY
12/22/2008 ELECTRIC - INTERMEDIATE RHOLLAND Approved IVRS - Inspection :*
1. SECURE VDV CABLING UPON EXITING OF CABLE TRAY
2. SUPPORT VDV CABLING AS PER 725.24, 800.24, 300.11, 725.3, 800.3

OK 2X4 LAY-INS 5 WEST 1/2
OK BORDERS ONLY 5 WEST 1/2
12/22/2008 MECHANICAL - ABOVE CEILING MRAMBER Approved IVRS - Inspection :*
12/22/2008 ELECTRIC - PROGRESS RHOLLAND Approved IVRS - Inspection :*
12/31/2008 MECHANICAL - PROGRESS MRAMBER Approved IVRS - Inspection :*
1) 5TH FLOOR OK FOR TILES
12/31/2008 ELECTRIC - ABOVE CEILING RHOLLAND Approved IVRS - Inspection :*
5TH FLOOR:
1) DISCONNECTS TO A/C IN AN UNSAFE MOUNTING CONDITIONS
2) CLOSE OPENINGS TO BOXES WITH LIVE CIRCUITS
3) CAP UNUSED RELOC BLOCKS
4) CAP UNUSED CONDUITS
5) SUPPORT WIRES NEEDED FOR EXIT SIGNS
6) SUPPORT RELOCK WIRING PER APPLICABLE CODES
7) FINISH VDV CABELING
8) OK TO TILE EXCEPT AREAS NOTED
6TH FLOOR:
1) CHECK VDV CABELING THRU ACCESS OPENINGS
2) OK HARD LID LOBBY
12/31/2008 FIRE SPKLR - FINAL LTHOMAS Approved
01/20/2009 FIRE - FINAL LTHOMAS Approved
01/21/2009 PLUMBING - FINAL RMYERS Approved IVRS - Inspection :*
01/26/2009 SIGN - FINAL JYBARRA Approved IVRS - Inspection :*
01/26/2009 NPPO - FINAL ACONNOR Approved N/A
01/26/2009 LANDSCAPE - FINAL ACONNOR Approved N/A
01/27/2009 RIGHT OF WAY - FINAL MOTERO Approved
01/29/2009 MECHANICAL - FINAL JMILITEL Approved IVRS - Inspection :*
01/30/2009 BUILDING - PROGRESS AQUIROZ Approved IVRS - Inspection :*
02/04/2009 ELECTRIC - RECONNECT RHOLLAND Approved IVRS - Inspection :*
02/04/2009 ELECTRIC - CONSTRUCTION POWER RHOLLAND Approved IVRS - Inspection :*
02/04/2009 ENGINEERING - FINAL LHANLY Approved THIS INSPECTION WAS SCHEDULED 1-26-09 BUT NO RESULTS WERE ENTERED. NO WORK AT THIS SITE OCCURED ON THE EXTERIOR OF THE BUILDING. EXISTING CONDITIONS MAINTAINED.
02/04/2009 BUILDING - FINAL LHANLY Approved
02/05/2009 ELECTRIC - FINAL LHANLY Approved CONTRACTURAL WORK ON THIS PERMIT COMPLETE. NEC ARTICLE 240.33 ALLOWS FOR OTHER THAN VERTICAL MOUNTING OF DISCONNECTS WHEN IMPRACTIABLE. PER MANUFACTURER OF EQUIPMENT, AND AZ REGISTERED ENGINEER THE CIELING MOUNT OF THE G.E. "TH" DISCONNECTS IS SUITABLE.
02/09/2009 PERMIT FINALED LJACKSON Approved

Documents

File Name Document Type  
TEMP C OF O_01-20-2009.TIF CERT OF OCC VIEW
C OF O_02-05-2009.TIF CERT OF OCC VIEW
C OF O_05-07-2009.TIF CERT OF OCC VIEW
001__T1.1.TIF CONSTRPLANS VIEW
002__C1.1.TIF CONSTRPLANS VIEW
003__A0.1.TIF CONSTRPLANS VIEW
004__A0.2.TIF CONSTRPLANS VIEW
005__A1.1.TIF CONSTRPLANS VIEW
006__A1.2.TIF CONSTRPLANS VIEW
007__A1.5.TIF CONSTRPLANS VIEW
008__A1.6.TIF CONSTRPLANS VIEW
009__A2.1.TIF CONSTRPLANS VIEW
010__A2.2.TIF CONSTRPLANS VIEW
011__A3.1.TIF CONSTRPLANS VIEW
012__A3.2.TIF CONSTRPLANS VIEW
013__A4.1.TIF CONSTRPLANS VIEW
014__A5.1.TIF CONSTRPLANS VIEW
015__A6.1.TIF CONSTRPLANS VIEW
016__A7.1.TIF CONSTRPLANS VIEW
017__M1.1.TIF CONSTRPLANS VIEW
018__M1.2.TIF CONSTRPLANS VIEW
019__M2.1.TIF CONSTRPLANS VIEW
020__M3.1.TIF CONSTRPLANS VIEW
021__P1.1.TIF CONSTRPLANS VIEW
022__P2.1.TIF CONSTRPLANS VIEW
023__E1.1.TIF CONSTRPLANS VIEW
024__E1.2.TIF CONSTRPLANS VIEW
025__E2.1.TIF CONSTRPLANS VIEW
026__E2.2.TIF CONSTRPLANS VIEW
027__E3.1.TIF CONSTRPLANS VIEW
028__E3.2.TIF CONSTRPLANS VIEW
029__E4.1.TIF CONSTRPLANS VIEW
030__E5.0.TIF CONSTRPLANS VIEW
031__E6.0.TIF CONSTRPLANS VIEW
032__E7.0.TIF CONSTRPLANS VIEW
033__E8.0.TIF CONSTRPLANS VIEW
T08CM03397_APPROVAL.PDF DOCUMENTS VIEW
MEMO.TIF DOCUMENTS VIEW
None DOCUMENTS VIEW