Permit Details

Status:
C of o
Type:
COMMERCIAL ALTERATION
Address:
333 W AJO WY
Apply Date:
08/18/2008
Applicant:
N/A
Description:
TI: OFFICE
Contractors:
  • T K R L L C

Permit Reviews

Permit Number - T08CM02806
Permit Status: C of o
Permit Description: TI: OFFICE
Start Date Submittal Complete Date Status  
08/18/2008 PLANS OK TO SUBMIT - COMM 08/18/2008 COMPLETED Review Details
08/18/2008 COMMERCIAL TI 09/19/2008 COMPLETED Review Details
09/19/2008 RESUBMITTAL 10/01/2008 COMPLETED Review Details
10/01/2008 RESUBMITTAL 10/08/2008 COMPLETED Review Details
12/31/2009 REVISION - - 1ST 12/31/2009 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T08CM02806
Permit Status: C of o
Permit Description: TI: OFFICE
Total Outstanding Activity Conditions - 1
Date Name
08/18/2008 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Completed Inspections

Permit Status: C of o
Permit Number: T08CM02806
Permit Description: TI: OFFICE
Total Completed Inspections - 23
Date Description Inspector Results Comments
11/13/2008 BUILDING ABOVE CEILING MHENSON Approved IVRS - Inspection :*
REMAINING CEILING PATCHES IN OFFICE AREAS

NEED TO CALL FOR ELEC. INTERMEDIATES BEFORE COVERING
11/13/2008 FRAMING MHENSON Approved IVRS - Inspection :*
2 WINDOWS ON SO. WALL FRAMING OK PHASE 1 LINTEL H1
11/17/2008 SHEET ROCK NAILING JBURGE Approved IVRS - Inspection :*
2 @ WINDOWS ON SOUTH WALL (H1) --
OK TO TAPE PROGRESS AREAS
11/19/2008 PLUMBING - GAS PRESSURE TEST RLEDONNE Approved IVRS - Inspection :*
CAP GAS PIPE IN WATER HEATER ROOM
10/09/2009 BUILDING - PROGRESS GDABBS Approved IVRS - Inspection :*
1) SHEETROCK PATCHES OK
10/09/2009 PLUMBING - PROGRESS RLEDONNE Approved IVRS - Inspection :*
10/09/2009 PLUMBING - INTERMEDIATE RLEDONNE Approved IVRS - Inspection :*
10/09/2009 ROOF NAILING GDABBS Approved IVRS - Inspection :*
12/03/2009 PLUMBING - ROUGH, SOIL RLEDONNE Approved IVRS - Inspection :*
OUTSIDE BUILDING TIE IN OK (ONLY)
12/29/2009 MECHANICAL - ABOVE CEILING MRAMBER Approved IVRS - Inspection :
See detailed listing on site.| 999*
1) ITEMS 7 AND 8 DATED 10/13/09 NOT COMPLETE AT THIS TIME
2) ITEM 13 DATED 10/13/09 NOT COMPLETE
3) ALL PVC EXPOSED TO EXTERIOR TO BE PAINTED
12/29/2009 BUILDING - FINAL MHENSON Approved IVRS - Inspection :*
1) NEED FIRE, ENGINEERING, PLUMBING, ELECTRIC AND MECHANICAL FINALS
2) RESTROOM SIGNAGE 60" TO CENTER
3) 34" MAX TO TOP OF BATH COUNTERS
4) NO KNOWLEDGE LEVER KNOBS RESTROOMS
5) WOMENS TOILET NEEDS TO BE 16 TO 18" OFF WALL
12/29/2009 ELECTRIC - INTERMEDIATE RHOLLAND Approved IVRS - Inspection :
The wiring is not complete or does not comply with code.| 245*
1) BOXES MORE THAN 1/4" 314.20
2) MAINTAIN WORKING CLEARANCES IN FRONT OF PANEL "A"-CANNOT ACCESS TO INSPECT
3) COUNTER RECEPT BREAKROOM TO BE GFCI PROTECTED
4) CLOSET FIXTURE TO BE PER 410.8 (D)
5) WHERE IS A/C AND EXHAUST FAN RELAY PLANS
6) FIXTURES NOT PER PLANS
7) PLEASE VERIFY INSPECTION REPORT FOR OCCUPIED AREAS
8) POINTED OUT TO CONTRACTOR POTENTIAL FIRE RISKS ON ROOF
12/29/2009 PLUMBING - FINAL RLEDONNE Approved IVRS - Inspection :*
1) CALL IN ALL INSPECTIONS
2) PROVIDE APPROVED PLAN WITH ALL CHANGES
3) ADD SUPPPORT AT WATER HEATER WATER PIPING
12/29/2009 MECHANICAL - FINAL MRAMBER Approved IVRS - Inspection :
See detailed listing on site.| 999*
12/29/2009 ELECTRIC - FINAL RHOLLAND Approved IVRS - Inspection :
The wiring is not complete or does not comply with code.| 245*
12/29/2009 ELECTRIC - ABOVE CEILING RHOLLAND Approved IVRS - Inspection :
The wiring is not complete or does not comply with code.| 245*
01/11/2010 ENGINEERING - FINAL MCARREON Approved
01/11/2010 FIRE - FINAL DSIWARSKI Approved Approved
01/11/2010 SIGN - FINAL JYBARRA Approved IVRS - Inspection :*
01/11/2010 NPPO - FINAL ACONNIOR Approved
01/11/2010 LANDSCAPE - FINAL ACONNIOR Approved
01/12/2010 RIGHT OF WAY - FINAL LLopez Approved
01/13/2010 PERMIT FINALED JWEATHER Approved

Documents

File Name Document Type  
C OF O_01-14-2010.TIF CERT OF OCC VIEW
ASBESTOSSURVEY DOCUMENTS VIEW
None DOCUMENTS VIEW
001__T-1.TIF CONSTRPLANS VIEW
002__A-1.TIF CONSTRPLANS VIEW
003__A-1.1.TIF CONSTRPLANS VIEW
004__A-2.TIF CONSTRPLANS VIEW
005__MD-1.TIF CONSTRPLANS VIEW
006__M-1.TIF CONSTRPLANS VIEW
007__M-2.TIF CONSTRPLANS VIEW
008__M-3.TIF CONSTRPLANS VIEW
009__M-4.TIF CONSTRPLANS VIEW
010__PD-1.TIF CONSTRPLANS VIEW
011__P-1.TIF CONSTRPLANS VIEW
012__P-2.TIF CONSTRPLANS VIEW
013__P-3.TIF CONSTRPLANS VIEW
014__P-4.TIF CONSTRPLANS VIEW
015__P-5.TIF CONSTRPLANS VIEW
016__E-1.TIF CONSTRPLANS VIEW