Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Details

Status:
C of o
Type:
COMMERCIAL ALTERATION
Address:
1991 E AJO WY
Apply Date:
08/04/2008
Applicant:
N/A
Description:
TI:OFFICE
Architects:
  • PETRICK KEVIN BLAKE
Contractors:
  • BENTLEY DRYWALL DESIGNS INC ,
  • PRESTON INSULATION ,
  • SWEETWATER GROUP L L C ,

Permit Reviews

Permit Number - T08CM02673
Permit Status: C of o
Permit Description: TI:OFFICE
Start Date Submittal Complete Date Status  
01/12/2009 REVISION - - 2ND 01/12/2009 COMPLETED Review Details
08/04/2008 COMMERCIAL TI 12/18/2008 COMPLETED Review Details
12/18/2008 REVISION - - 1ST 12/24/2008 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T08CM02673
Permit Status: C of o
Permit Description: TI:OFFICE
Total Outstanding Activity Conditions - 1
Date Name
08/04/2008 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Completed Inspections

Permit Status: C of o
Permit Number: T08CM02673
Permit Description: TI:OFFICE
Total Completed Inspections - 25
Date Description Inspector Results Comments
11/14/2008 PLUMBING - ROUGH, SOIL RLEDONNE Approved IVRS - Inspection :*
CELL#: 520-465-6322
PRE-SLAB OK
12/03/2008 ELECTRIC - INTERMEDIATE DSANTACR Approved IVRS - Inspection :*
OK WALLS ROUGH, HARD LIDS
12/03/2008 PLUMBING - INTERMEDIATE RLEDONNE Approved IVRS - Inspection :*
FIRST FLOOR PIPING IN WALL TEST OK
12/12/2008 FRAMING MHENSON Approved IVRS - Inspection :*
NEED REVISED PLAN AND RFI's
12/16/2008 SHEET ROCK NAILING MHENSON Approved IVRS - Inspection :*
1. PER A2 NOTES 6 & 7 1/2 SAG RESISTANT DRYWALL ON CEILING JOIST 5/8 USED
NEED RFI
2. TAPE CEILING AT OWN RISK
12/30/2008 MECHANICAL - ABOVE CEILING MRAMBER Approved IVRS - Inspection :*
01/08/2009 PLUMBING - PROGRESS RLEDONNE Approved IVRS - Inspection :*
01/12/2009 ROOF NAILING MHENSON Approved IVRS - Inspection :*
TI ROOF NAILING DONE WITH SHELL
01/12/2009 BUILDING ABOVE CEILING MHENSON Approved IVRS - Inspection :*
01/15/2009 TEP CLEARANCE - AM JWEATHER Approved TEC CLEARED PER R. JIROUDEK
01/21/2009 ELECTRIC - TEMP POWER FOR TEST DSANTACR Approved
01/21/2009 ELECTRIC - ABOVE CEILING DSANTACR Approved IVRS - Inspection :*
01/21/2009 ELECTRIC - FINAL DSANTACR Approved IVRS - Inspection :*
01/21/2009 FIRE SPKLR - FINAL LTHOMAS Approved
01/21/2009 FIRE - FINAL LTHOMAS Approved
01/23/2009 PLUMBING - FINAL RLEDONNE Approved IVRS - Inspection :*
01/27/2009 BUILDING - PROGRESS MHENSON Approved IVRS - Inspection :*
01/29/2009 MECHANICAL - FINAL JMILITEL Approved IVRS - Inspection :*
CORRECTIONS HAVE BEEN MADE
AIR BALANCE OK
OK FOR FINAL
01/29/2009 BUILDING - FINAL MHENSON Approved IVRS - Inspection :*
OK FOR C OF O
01/30/2009 NPPO - FINAL ACONNOR Approved N/A
01/30/2009 LANDSCAPE - FINAL ACONNOR Approved N/A
01/30/2009 ENGINEERING - FINAL MAVERY Approved
01/30/2009 SIGN - FINAL JYBARRA Approved IVRS - Inspection :*
02/02/2009 PERMIT FINALED LJACKSON Approved
02/02/2009 RIGHT OF WAY - FINAL LLOPEZ Approved

Documents

File Name Document Type  
C OF O_02-02-2009.TIF CERT OF OCC VIEW
001__T.1.TIF CONSTRPLANS VIEW
002__A.1.TIF CONSTRPLANS VIEW
003__A.2.TIF CONSTRPLANS VIEW
004__A.3.TIF CONSTRPLANS VIEW
005__M.1.TIF CONSTRPLANS VIEW
006__P.1.TIF CONSTRPLANS VIEW
007__E.1.TIF CONSTRPLANS VIEW
008__E.2.TIF CONSTRPLANS VIEW
None DOCUMENTS VIEW