Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit: T08CM02655
Permit Details
Apply Date:
08/01/2008
Applicant:
N/A
Description:
NEW: MIDDLE SCHOOL (GYM) RINCON VISTA MIDDLE SCHOOL BUILDING #2
Contractors:
- DIVERSIFIED DESIGN AND CONSTRUCT
Permit Reviews
Permit Number - T08CM02655
Permit Status: C of o
Permit Description: NEW: MIDDLE SCHOOL (GYM)
RINCON VISTA MIDDLE SCHOOL BUILDING #2
Start Date | Submittal | Complete Date | Status |
---|---|---|---|
01/14/2009 | 3RD PARTY REVIEW-REVISION/OTHER | 01/15/2009 | COMPLETED |
05/07/2009 | 3RD PARTY REVIEW-REVISION/OTHER-2ND | 05/08/2009 | COMPLETED |
07/16/2009 | 3RD PARTY REVIEW-REVISION/OTHER | 07/16/2009 | COMPLETED |
08/01/2008 | PLANS OK TO SUBMIT - 3RD PARTY | 08/01/2008 | COMPLETED |
08/01/2008 | 3RD PARTY REVIEW-COMMERCIAL | 09/17/2008 | COMPLETED |
09/17/2008 | POST 3RD PARTY REVIEW | 09/19/2008 | COMPLETED |
09/19/2008 | POST 3RD PARTY REVIEW | 10/01/2008 | COMPLETED |
10/01/2008 | POST 3RD PARTY REVIEW | 10/06/2008 | COMPLETED |
12/18/2008 | 3RD PARTY REVIEW-REVISION/OTHER | 12/22/2008 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T08CM02655
Permit Status: C of o
Permit Description: NEW: MIDDLE SCHOOL (GYM)
RINCON VISTA MIDDLE SCHOOL BUILDING #2
Total Outstanding Activity Conditions - 1
Date | Name |
---|---|
08/01/2008 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: C of o
Permit Number: T08CM02655
Permit Description: NEW: MIDDLE SCHOOL (GYM)
RINCON VISTA MIDDLE SCHOOL BUILDING #2
Total Completed Inspections - 41
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
10/14/2008 | EXCAVATION/LAYOUT REBAR & ZON | GDABBS | Approved | IVRS - Inspection :* PERIMETER FOOTINGS FOR BLDG. #2 SOUTH END @ GL/GO SOUTH ROOMS 201, 202, 203, 204, 205 SPECIAL INSPECTOR ACCEPTED |
10/16/2008 | STEM WALL/RETAINING WALL | GDABBS | Approved | IVRS - Inspection :* PERIMETER & INTERIOR STEM WALLS @ GRID LINES A.0 TO G.0/1.0 TO 2.0 - 53 L.F SOUTH OF GL/1.0 TO AL - 36 L.F EAST OF GL/2.0/AG - 36 L.F NORTH OF A.0/36 LF EAST OF 2.0 36 LF NORTH OF A.0/53 LF NORTH OF GL/1.0 & ROOMS #201, 202, 203, 204, 205 |
10/22/2008 | PLUMBING - ROUGH, SOIL | RRICH | Approved | IVRS - Inspection :* WATER TEST UNDERGROUND PER RED LINE TO 2-WAY CLEANOUT OK |
10/28/2008 | PLUMBING - YARD WTR LINE/TEST | RRICH | Approved | IVRS - Inspection :* 2" T/K SOUTH 2 1/2 T/K NORTH STUB UP & OUT OF BLD. OK |
11/06/2008 | PLUMBING - PRE SLAB | RLEDONNE | Approved | IVRS - Inspection :* |
11/07/2008 | BUILDING PRE-SLAB | GDABBS | Approved | IVRS - Inspection :* MAIN BLDG. PAD |
11/10/2008 | PLUMBING - INTERMEDIATE | RLEDONNE | Approved | IVRS - Inspection :* TYPE L COPPER PRE-SLAB FOR BLOCK WALL #214, #203, #202 |
11/12/2008 | ELECTRIC - UFER | RJIROUDE | Approved | IVRS - Inspection :* |
12/10/2008 | ELECTRIC - INTERMEDIATE | RJIROUDE | Approved | IVRS - Inspection :* OK TOPOUT ALL MASONRY WALLS |
12/15/2008 | ELECTRIC - UNDERGROUND | RJIROUDE | Approved | IVRS - Inspection :* OK 1" PVC FOR GATE MOTOR |
12/17/2008 | REINFORCED MASONRY PRE-GROUT | GDABBS | Approved | IVRS - Inspection :* CMU WALL REINFORCEMENT @ GRID LINES G.0/0 TO 28' NORTH FROM S/W CORNER OF GYM FROM 28'0" TO TOP OUT SPECIAL INSPECTION PERFORMED |
01/30/2009 | PLUMBING - SEWER HCS CONNECT | RRICH | Approved | IVRS - Inspection :* |
02/12/2009 | PLUMBING - GAS PRESSURE TEST | RLEDONNE | Approved | IVRS - Inspection :* 1) NORTH SINK GAS PIPING TEST |
02/17/2009 | ROOF NAILING | GDABBS | Approved | IVRS - Inspection :* |
04/02/2009 | PLUMBING - ABOVE CEILING | RRICH | Approved | IVRS - Inspection :* |
04/03/2009 | SHEET ROCK NAILING | GDABBS | Approved | IVRS - Inspection :* HARD LIDS NORTH SIDE |
04/06/2009 | U VALUE FOR WINDOW | GDABBS | Approved | IVRS - Inspection :* |
04/07/2009 | PLUMBING - GAS PRESS TEST FNL | RRICH | Approved | IVRS - Inspection :* GAS CARD WITH CHUCK 1. PROVIDE STORM COLLARS FOR WATER HEATER VENT THRU ROOF AND TERMINATE T&P 90 DEG. DOWN |
04/08/2009 | FRAMING | GDABBS | Approved | IVRS - Inspection :* |
04/08/2009 | EXT METAL CLIPS/EXT SHEATHING | GDABBS | Approved | IVRS - Inspection :* |
04/09/2009 | STUCCO MESH | GDABBS | Approved | IVRS - Inspection :* |
04/09/2009 | BUILDING ABOVE CEILING | GDABBS | Approved | IVRS - Inspection :* |
06/29/2009 | NPPO - FINAL | ACONNOR | Approved | N/A |
06/29/2009 | LANDSCAPE - FINAL | ACONNOR | Approved | N/A |
07/09/2009 | PLUMBING - FINAL | RRICH | Approved | IVRS - Inspection :* |
07/09/2009 | FIRE SPKLR - FINAL | LTHOMAS | Approved | |
07/09/2009 | FIRE SPKLR - UG, PIPING, HYDRO | LTHOMAS | Approved | |
07/09/2009 | FIRE - LANE SIGNS | LTHOMAS | Approved | |
07/09/2009 | FIRE - FINAL | LTHOMAS | Approved | |
07/13/2009 | MECHANICAL - FINAL | JMILITEL | Approved | IVRS - Inspection :* 1) AIR BALANCE OK 2) DUCT SMOKE DETECTOR TEST OK 3) OK FOR FINAL |
07/13/2009 | MECHANICAL - ABOVE CEILING | JMILITEL | Approved | IVRS - Inspection :* |
07/13/2009 | MECHANICAL - INTERMEDIATE | JMILITEL | Approved | IVRS - Inspection :* |
07/15/2009 | OUTDOOR LIGHTING FINAL | RJIROUDE | Approved | IVRS - Inspection :* |
07/15/2009 | ELECTRIC - OUTDOOR LIGHTING | RJIROUDE | Approved | IVRS - Inspection :* |
07/15/2009 | ELECTRIC - ABOVE CEILING | RJIROUDE | Approved | IVRS - Inspection :* |
07/16/2009 | RIGHT OF WAY - FINAL | MCASTRO | Approved | PER EMAIL |
07/28/2009 | ELECTRIC - FINAL | RJIROUDE | Approved | IVRS - Inspection :* |
07/29/2009 | BUILDING - PROGRESS | GDABBS | Approved | per final |
07/29/2009 | BUILDING - FINAL | GDABBS | Approved | IVRS - Inspection :* |
07/29/2009 | ENGINEERING - FINAL | JFEMLING | Approved | Approved |
11/02/2009 | PERMIT FINALED | BGRANT | Approved |