Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit: T08CM02382
Permit Details
Apply Date:
07/07/2008
Applicant:
N/A
Description:
UPGRADE:HVAC
Contractors:
- TUCSON BUILDING AND REMODELING I
Permit Reviews
Permit Number - T08CM02382
Permit Status: Final
Permit Description: UPGRADE:HVAC
Start Date | Submittal | Complete Date | Status |
---|---|---|---|
06/26/2009 | REVISION - - 1ST | 06/30/2009 | COMPLETED |
07/07/2008 | PLANS OK TO SUBMIT - 3RD PARTY | 07/14/2008 | COMPLETED |
07/14/2008 | COMMERCIAL NEW | 08/08/2008 | COMPLETED |
08/07/2009 | REVISION - - 2ND | 08/07/2009 | COMPLETED |
08/27/2008 | RESUBMITTAL | 12/15/2008 | COMPLETED |
09/03/2009 | REVISION - - 3RD | 09/03/2009 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T08CM02382
Permit Status: Final
Permit Description: UPGRADE:HVAC
Total Outstanding Activity Conditions - 1
Date | Name |
---|---|
07/07/2008 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: Final
Permit Number: T08CM02382
Permit Description: UPGRADE:HVAC
Total Completed Inspections - 13
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
05/05/2009 | PLUMBING - FINAL | RMYERS | Approved | IVRS - Inspection :* 1. NEW GAS SERVICE TO ROOFTOP UNITS OK PRESSURE TEST OK 2. ASK MECHANICAL INSPECTOR TO LEAVE GAS CARD |
05/05/2009 | PLUMBING - PROGRESS | RMYERS | Approved | IVRS - Inspection :* |
05/05/2009 | PLUMBING - GAS PRESSURE TEST | RMYERS | Approved | IVRS - Inspection :* |
05/05/2009 | PLUMBING - INTERMEDIATE | RMYERS | Approved | IVRS - Inspection :* |
05/18/2009 | ELECTRIC - FINAL | DSANTACR | Approved | IVRS - Inspection :* |
05/18/2009 | ELECTRIC - UNDERGROUND | DSANTACR | Approved | IVRS - Inspection :* |
05/18/2009 | ELECTRIC - INTERMEDIATE | DSANTACR | Approved | IVRS - Inspection :* |
05/18/2009 | ELECTRIC - ABOVE CEILING | DSANTACR | Approved | IVRS - Inspection :* |
05/20/2009 | BUILDING - PROGRESS | GDABBS | Approved | IVRS - Inspection :* ABOVE CEILING ON ALL THREE FLOORS COMPLETE $150.00 PAID AFTER HRS. INSP. CHECK #005066 |
10/30/2009 | MECHANICAL - FINAL | LHANLY | Approved | IVRS - Inspection :* |
10/30/2009 | MECHANICAL - ABOVE CEILING | LHANLY | Approved | IVRS - Inspection :* |
10/30/2009 | BUILDING - FINAL | LHANLY | Approved | IVRS - Inspection :* |
11/02/2009 | PERMIT FINALED | JWEATHER | Approved |