Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

PRO is currently experiencing an outage. Some documents and records may not be available on PRO momentarily. We apologize for the inconvenience and are working to restore full access.

Permit Details

Status:
C of o
Type:
MULTI FAMILY NEW
Address NEW:
2121 E BROADWAY BL 01
Apply Date:
05/14/2008
Applicant:
N/A
Description:
NEW APARTMENT BUILDING #5
Architects:
  • MCQUILLEN, THOMAS
Contractors:
  • TOFEL CONSTRUCTION

Permit Reviews

Permit Number - T08CM01565
Permit Status: C of o
Permit Description: NEW APARTMENT BUILDING #5
Start Date Submittal Complete Date Status  
02/04/2009 RESUBMITTAL 09/28/2009 COMPLETED Review Details
05/14/2008 PLANS OK TO SUBMIT - 3RD PARTY 05/14/2008 COMPLETED Review Details
05/14/2008 3RD PARTY REVIEW-COMMERCIAL 09/22/2008 COMPLETED Review Details
09/22/2008 POST 3RD PARTY REVIEW 02/04/2009 COMPLETED Review Details
10/06/2009 REVISION - - 1ST 11/04/2009 COMPLETED Review Details
11/04/2009 REVISION - - 1ST 11/10/2009 COMPLETED Review Details
11/10/2009 REVISION - - 1ST 11/19/2009 COMPLETED Review Details
11/19/2009 REVISION - - 3RD 11/23/2009 ACTIVE Review Details
11/19/2009 REVISION - - 2ND 11/19/2009 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T08CM01565
Permit Status: C of o
Permit Description: NEW APARTMENT BUILDING #5
Total Outstanding Activity Conditions - 1
Date Name
05/14/2008 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Completed Inspections

Permit Status: C of o
Permit Number: T08CM01565
Permit Description: NEW APARTMENT BUILDING #5
Total Completed Inspections - 37
Date Description Inspector Results Comments
10/19/2009 PLUMBING - ROUGH, SOIL RMYERS Approved IVRS - Inspection :*
1) PVC SCHEDULE 40 UNDERGROUND DWV OK TO COVER
10/23/2009 ELECTRIC - UNDERGROUND RMORENO Approved IVRS - Inspection :*
ROM EDSD BUILDING TO WEST CENTER OF BUILDING OK
TRENCH 2*4", 1.3, 1 1 1/2 ALL OK
11/04/2009 ELECTRIC - INTERMEDIATE RMORENO Approved IVRS - Inspection :*
1) UFER #2 OK 3 PHASE HOUSE PANLE 2HA1 OK 200 A, UFER #2 PANEL 2A 800 A
11/05/2009 PLUMBING - PROGRESS RMYERS Approved IVRS - Inspection :*
1) CONDENSATE AND T & P RELIEF DRAIN INSTALLED PER PLAN
2) OK TO CONCRETE
11/05/2009 BUILDING PRE-SLAB MHENSON Approved IVRS - Inspection :*
1) BLDG SLAB OK TO POUR
2) COMPLIANT WESTERN TECH SPECIAL INSPECTION
11/18/2009 EXCAVATION/LAYOUT REBAR & ZON JBURGE Approved 1) FOOTING/MC1 AS PER DETAILS #113 & 114 PAGE S3.0-OK TO POUR FOOTING
12/02/2009 REINFORCED MASONRY PRE-GROUT JBURGE Approved MASONRY PRE-GROUT PARTIAL 10 COLUMNS TOPPED OUT @9' - OK TO GROUT PROGRESS AREAS.
12/18/2009 BUILDING - PROGRESS JBURGE Approved IVRS - Inspection :*
1) 2ND FLOOR SUB FLOOR OK TO FRAME
03/05/2010 FRAMING JBURGE Approved IVRS - Inspection :*
03/09/2010 STUCCO MESH JBURGE Approved IVRS - Inspection :*
1) OK TO STUCCO MESH
03/18/2010 PLUMBING - INTERMEDIATE RMYERS Approved IVRS - Inspection :*
1) PEX OK
2) PVC OK
3) FLANGES OK
05/12/2010 SHEET ROCK NAILING JBURGE Approved IVRS - Inspection :*
1) OK TO TAPE THROUGHOUT
06/16/2010 ELECTRIC - CABLE DROP DSANTACR Approved IVRS - Inspection :*
07/02/2010 BUILDING ABOVE CEILING JBURGE Approved IVRS - Inspection :*
1) OK TO SET CEILING TILES
07/07/2010 ELECTRIC - ABOVE CEILING DSANTACR Approved IVRS - Inspection :*
07/28/2010 ELECTRIC - FINAL RMORENO Approved IVRS - Inspection :*
08/05/2010 PLUMBING - FINAL RMYERS Approved IVRS - Inspection :*
08/05/2010 PLUMBING - SEWER HCS CONNECT RMYERS Approved IVRS - Inspection :*
08/05/2010 PLUMBING - YARD WTR LINE/TEST RMYERS Approved IVRS - Inspection :*
08/05/2010 PLUMBING - ABOVE CEILING RMYERS Approved IVRS - Inspection :*
08/06/2010 MECHANICAL - FINAL MRAMBER Approved IVRS - Inspection :*
08/06/2010 MECHANICAL - PROGRESS MRAMBER Approved IVRS - Inspection :*
08/06/2010 MECHANICAL - ABOVE CEILING MRAMBER Approved IVRS - Inspection :*
08/06/2010 MECHANICAL - INTERMEDIATE MRAMBER Approved IVRS - Inspection :*
08/09/2010 FIRE SPKLR - FINAL LTHOMAS Approved
08/09/2010 FIRE - ALARM FINAL LTHOMAS Approved
08/09/2010 FIRE - FINAL LTHOMAS Approved
08/09/2010 U VALUE FOR WINDOW JBURGE Approved IVRS - Inspection :*
08/09/2010 EXT METAL CLIPS/EXT SHEATHING JBURGE Approved IVRS - Inspection :*
08/11/2010 ELECTRIC - UFER RMORENO Approved
08/11/2010 OUTDOOR LIGHTING FINAL RMORENO Approved
08/11/2010 ELECTRIC - OUTDOOR LIGHTING RMORENO Approved
08/11/2010 ELECTRIC - PROGRESS RMORENO Approved
08/11/2010 ELECTRIC - RECONNECT RMORENO Approved
08/11/2010 ELECTRIC - CONSTRUCTION POWER RMORENO Approved
08/11/2010 ROOF NAILING JBURGE Approved
08/11/2010 BUILDING - FINAL JBURGE Approved IVRS - Inspection :*