Permit: T08CM01201
Permit Details
Apply Date:
04/15/2008
Applicant:
N/A
Description:
TI:OFFICE - TEXAS INSTRUMENTS
Architects:
- MORROW, KEVIN THOMAS
Contractors:
- BARKER MORRISSEY CONTRACTING INC
Permit Reviews
Permit Number - T08CM01201
Permit Status: C of o
Permit Description: TI:OFFICE - TEXAS INSTRUMENTS
Start Date | Submittal | Complete Date | Status |
---|---|---|---|
04/15/2008 | PLANS OK TO SUBMIT - 3RD PARTY | 04/15/2008 | COMPLETED |
04/15/2008 | 3RD PARTY REVIEW-COMMERCIAL TI | 05/20/2008 | COMPLETED |
05/20/2008 | POST 3RD PARTY REVIEW | 05/21/2008 | COMPLETED |
07/30/2008 | 3RD PARTY REVIEW-REVISION/OTHER | 07/31/2008 | COMPLETED |
10/06/2008 | 3RD PARTY REVIEW-REVISION/OTHER | 10/16/2008 | COMPLETED |
11/24/2008 | 3RD PARTY REVIEW-REVISION/OTHER | 11/25/2008 | COMPLETED |
12/17/2008 | 3RD PARTY REVIEW-REVISION/OTHER | 12/17/2008 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T08CM01201
Permit Status: C of o
Permit Description: TI:OFFICE - TEXAS INSTRUMENTS
Total Outstanding Activity Conditions - 1
Date | Name |
---|---|
04/15/2008 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: C of o
Permit Number: T08CM01201
Permit Description: TI:OFFICE - TEXAS INSTRUMENTS
Total Completed Inspections - 29
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
08/06/2008 | PLUMBING - ROUGH, SOIL | RRICH | Approved | IVRS - Inspection :* 1) UNDERGROUND DWV WATER TEST OK |
08/12/2008 | PLUMBING - PRE SLAB | RRICH | Approved | IVRS - Inspection :* |
08/25/2008 | FRAMING | GDABBS | Approved | IVRS - Inspection :* BOTH FIRST AND SECOND FLOORS |
08/27/2008 | SHEET ROCK NAILING | GDABBS | Approved | IVRS - Inspection :* BALANCE OF 1ST AND 2ND FLOOR |
08/27/2008 | PLUMBING - INTERMEDIATE | RRICH | Approved | IVRS - Inspection :* |
09/19/2008 | PLUMBING - ABOVE CEILING | RRICH | Approved | IVRS - Inspection :* |
10/03/2008 | MECHANICAL - ABOVE CEILING | JMILITEL | Approved | IVRS - Inspection :* 1. WILL TEST FIRE/SMOKE DAMPER ON FINAL 2. PROVIDE ACCESS TO FIRE DAMPER & FIRE CAULK AROUND FLOOR PENETRATION 3. OK FOR CEILING TILES |
10/03/2008 | BUILDING ABOVE CEILING | GDABBS | Approved | IVRS - Inspection :* 2ND FLOOR COMPLETE OK |
10/03/2008 | ROOF NAILING | GDABBS | Approved | IVRS - Inspection :* |
10/10/2008 | ELECTRIC - TEMP POWER FOR TEST | RHOLLAND | Approved | IVRS - Inspection :* |
10/15/2008 | FIRE SPKLR - FINAL | LTHOMAS | Approved | |
10/16/2008 | MECHANICAL - FINAL | JMILITEL | Approved | IVRS - Inspection :* PROVIDE AIR BALANCE REPORT & INCLUDE DUCT SMOKE DETECTOR TEST |
10/16/2008 | MECHANICAL - INTERMEDIATE | JMILITEL | Approved | IVRS - Inspection :* |
10/16/2008 | BUILDING - PROGRESS | GDABBS | Approved | IVRS - Inspection :* OK FOR STOCKING, FURNITURE PLACEMENT & EQUIPMENT HOOK UP - NO OCCUPANCY OF OFFICE OR LAB STAFF WILL BE ALLOWED. THE ABOVE HAS BEEN OK'd BY THE MECH., ELEC., AND PLUMBING INSPECTORS PAID AFTER HOURS INSP. PAID $150.00 -- CHECK#001431 |
10/16/2008 | ELECTRIC - UFER | RJIROUDE | Approved | IVRS - Inspection :* |
10/16/2008 | ENGINEERING - FINAL | NKALAHAR | Approved | OK TO STOCK/INSTALL COMPUTERS (TEMP C OF O) |
10/17/2008 | RIGHT OF WAY - FINAL | WCASTRO | Approved | |
10/23/2008 | FIRE - FINAL | LTHOMAS | Approved | |
10/24/2008 | PLUMBING - FINAL | RRICH | Approved | IVRS - Inspection :* RECEIVED BACKFLOW CERTIFICATION FOR ICE MACHINE AFTER HRS. INSP. PAID BY ACCT. FOR BARKER MORRISSEY WITHDRAWAL PER LEE RAY OK TO OPEN AND MAKE AS PARTIAL FOR REVISION PER PHONE CALL WITH BOB RICH |
10/28/2008 | ELECTRIC - ABOVE CEILING | RJIROUDE | Approved | IVRS - Inspection :* |
10/28/2008 | ELECTRIC - INTERMEDIATE | RJIROUDE | Approved | IVRS - Inspection :* |
10/31/2008 | ELECTRIC - FINAL | RJIROUDE | Approved | IVRS - Inspection :* 1ST FLOOR 1. ONE EM LIGHT ON GEN. CKT. NOT WORKING 2. SEAL OPEN KNOCKOUTS ELECTRIC ROOM 3. CHECK WITH BUILDING INSPECTOR FOR TCO 1ST FLOOR I HAVE NO ISSUES 4. CHECK ON HANDLE TIES FOR WORK STATIONS |
10/31/2008 | BUILDING - FINAL | GDABBS | Approved | IVRS - Inspection :* 1ST FLOOR - OK TO OCCUPY UNDER EXISTING TCO PAID AFTER HRS. INSP. $150.00 FEE TO BE CHARGED TO BARKER MORRISSEY's ACCT. |
03/30/2009 | SIGN - FINAL | JYBARRA | Approved | IVRS - Inspection :* |
04/15/2009 | TEP CLEARANCE - PM | JWEATHER | Approved | TMPP CLEARED PER R. MORENO |
04/21/2009 | STUCCO MESH | GDABBS | Approved | |
04/21/2009 | BUILDING PRE-SLAB | GDABBS | Approved | |
04/21/2009 | EXCAVATION/LAYOUT REBAR & ZON | GDABBS | Approved | |
04/22/2009 | PERMIT FINALED | LJACKSON | Approved |