Inspection Status: Approved
Inspection History: ELECTRIC - INTERMEDIATE
Permit Number - T08CM01201
Inspection Description - ELECTRIC - INTERMEDIATE
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
03/30/2009 | ELECTRIC - INTERMEDIATE | Approved | IVRS - Inspection :* | |
03/27/2009 | ELECTRIC - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* | |
03/16/2009 | ELECTRIC - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* | |
03/13/2009 | ELECTRIC - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* | |
03/06/2009 | ELECTRIC - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* | |
10/28/2008 | ELECTRIC - INTERMEDIATE | Partial Approval | IVRS - Inspection :* | |
10/16/2008 | ELECTRIC - INTERMEDIATE | Partial Approval | IVRS - Inspection :* | |
10/15/2008 | ELECTRIC - INTERMEDIATE | Partial Approval | IVRS - Inspection :* 1. ENSURE MDV GROUNDS AND NEUTRALS SEPARATE 2. GEC TO TERMINATE @ NEUTRAL OR BONDING JUMPER IN XFMR 3. BONDING JUMPERS TO BE SIZED PROPERLY @ DS2 4. BONDING JUMPER FROM XFMR TO DISCONNECT TO BE SIZED PROPERLY 5. SEAL OPEN KNOCKOUTS 6. OK MAKE UP @ SES |
|
10/14/2008 | ELECTRIC - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* | |
10/10/2008 | ELECTRIC - INTERMEDIATE | Partial Approval | IVRS - Inspection :* ED @ 289-0328 - $150.00 CK#1432 1. RECEIVED GFI MAIN TEST & LETTER OF TORQUE 2. ONLY AUTHORIZED PERSONNEL TO HAVE ACCESS TO ELECTRICAL EQUIPMENT KATHY @ TEP 918-8271/904-5771 CALLED CLEARANCE INTO TEP, MIKE KEISER |
|
10/09/2008 | ELECTRIC - INTERMEDIATE | Partial Approval | IVRS - Inspection :* | |
08/29/2008 | ELECTRIC - INTERMEDIATE | Partial Approval | IVRS - Inspection :* OK PANEL WALLS RM 241 |
|
08/25/2008 | ELECTRIC - INTERMEDIATE | Partial Approval | IVRS - Inspection :* 1. OK WALLS RMS. 108, 208 2. INSTALL BOX DIVIDERS AT SWITCH LOCATIONS AS NEEDED |
|
08/20/2008 | ELECTRIC - INTERMEDIATE | Partial Approval | IVRS - Inspection :* OK WALLS RMS. 133, 110-115, 129, 232 |
|
08/15/2008 | ELECTRIC - INTERMEDIATE | Partial Approval | IVRS - Inspection :* OK 101-107, 141-144, 135-139, 118-125, 110-115, 201-207 |
|
08/06/2008 | ELECTRIC - INTERMEDIATE | Partial Approval | IVRS - Inspection :* 1) OK WALLS 2ND FLOOR ROOMS 226-229, 218-222, 237-240, 210-215 AND 233-236 |
|
07/23/2008 | ELECTRIC - INTERMEDIATE | Partial Approval | IVRS - Inspection :* OK AREA UNDER RAISED FLOOR OPEN AREAS 1ST & 2ND FLOOR - SEPARATE HOME RUNS TO NO MORE THAN 7 PER BUNDLE - BE AWARE OF HANDLE TIE REQUIREMENTS FOR OFFICE FURNITURE NEC 605.6 & 605.7 |