Permit Details

Status:
Final
Type:
SINGLE FAMILY COMPLIANCE
Address NEW:
7581 E IRVINGTON RD
Apply Date:
03/24/2008
Applicant:
BETSY JENNINGS
Description:
FIELD EVALUATION FOR APPLICABLE CODE COMPLIANCE. PORCH ADDITIONS, CARPORT ENCLOSURE, AND GARAGE. RESPONSE TO VIOLATION FROM DNR #T07DV13117

Permit Reviews

Permit Number - T08CM00956
Permit Status: Final
Permit Description: FIELD EVALUATION FOR APPLICABLE CODE COMPLIANCE. PORCH ADDITIONS, CARPORT ENCLOSURE, AND GARAGE. RESPONSE TO VIOLATION FROM DNR #T07DV13117
Start Date Submittal Complete Date Status  
03/24/2008 RESIDENTIAL BLDG/ZONING/ENGINE/NPPO 09/24/2008 COMPLETED Review Details
09/24/2008 RESIDENTIAL BLDG/WWM 10/28/2008 COMPLETED Review Details
12/10/2008 RESUBMITTAL 12/15/2008 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T08CM00956
Permit Status: Final
Permit Description: FIELD EVALUATION FOR APPLICABLE CODE COMPLIANCE. PORCH ADDITIONS, CARPORT ENCLOSURE, AND GARAGE. RESPONSE TO VIOLATION FROM DNR #T07DV13117
Total Outstanding Activity Conditions - 1
Date Name
03/24/2008 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Completed Inspections

Permit Status: Final
Permit Number: T08CM00956
Permit Description: FIELD EVALUATION FOR APPLICABLE CODE COMPLIANCE. PORCH ADDITIONS, CARPORT ENCLOSURE, AND GARAGE. RESPONSE TO VIOLATION FROM DNR #T07DV13117
Total Completed Inspections - 3
Date Description Inspector Results Comments
12/10/2008 BUILDING - PROGRESS LHANLY Approved 1) FRONT FAMILY ROOM (ENCLOSED CARPORT)
1A) ENCLOSED CARPORT BUILT CIRCA 1986. STRUCTURALLY SOUND PER ADOPTED CODES AT THAT TIME.
1B) ADDED LIGHT OUTLET ON EXTERIOR ABOVE SLIDING DOOR WILL NEED TO BE OPENED UP FOR VERIFICATION OF ELECTRIC COMPLIANCE.

2) REAR FAMILY ROOM
2A) THIS FAMILY ROOM CONSTRUCTION PRE-DATES 1976. ALL ASPECTS ARE IN GENERAL COMPLIANCE WITH CODES USED AT THAT TIME. NO SUBSTANDARD CONDITIONS NOTED AT THIS TIME.

3) SOUTH-EAST PORCH
3A) THIS SMALL PORCH WAS ADDED IN THE EARLY 1990'S. CORRECTIONS WILL BE REQUIRED.
3B) OWNER MAY USE A.35 CLIPS FROM FASCIA TO ALL RAFTERS ALONG THIS SECTION. FASCIA AT SOUTH SIDE WILL REQUIRE A GUSSET PLATE TO EXISTING FASCIA WITH 12 TOTAL HANGER SCREWS OR TICO NAILS. 2" TUBE STEEL POST WILL REQURE AN ADDITIONAL 1/2" BOLT TO SOUTH FASCIA.

4) EAST (REAR) PORCH
4A) THIS PORCH EASILY PREDATES 1976 AND WAS BUILT IN COMPLIANCE WITH THE CODES AT THAT TIME. THERE ARE MINOR MAINTENANCE ISSUES BUT NOTHING THAT WOULD REQUIRE IMMEDIATE CORRECTION AT THIS TIME.

5) UNATTACHED GARAGE
5A) GARAGE WAS BUILT CIRCA 1982 AND WAS DONE FROM A KIT THAT WAS FAIRLY COMMON AT THAT TIME. THERE HAS BEEN SOME DETERIORATION OVER THE YEARS THAT REQUIRES SOME STRUCTURAL CORRECTION.
5B) OWNER MAY INSTALL CABLE COLLAR TIES 4' O.C. STARTING FROM FRONT OF GARAGE. ADDITIONAL PLYWOOD COLLAR TIES WILL NEED TO BE INSTALLED AT BOTTOM OF RIDGE FOR EACH RAFTER SET AFTER THE CABLE TIES HAVE PROPERLY ALIGNED THE BUILDING.
5C) THERE IS SOME MISAPPLIED ROOF SHEATHING FROM 2 OR 3 YEAR OLD WIND DAMAGE THAT WILL NEED TO BE REPAIRED AFTER COLLAR TIES ARE ESTABLISHED.
5D) THE ELECTRICAL SUBPANEL WILL NEED FURTHER EVALUATION AND WILL REQUIRE SOME REPAIRS AFTER THE STRUCTURAL ISSUES ARE RESOLVED.
05/12/2009 BUILDING - FINAL JBURGE Approved IVRS - Inspection :*
05/13/2009 PERMIT FINALED BFLORES Approved