Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: T08CM00956

Parcel: 136284230


Addresses:

7581 E IRVINGTON RD

Inspection Status: Approved

Inspection History: BUILDING - PROGRESS

Date Description Inspector Results Comments
05/12/2009 BUILDING - PROGRESS Approved IVRS - Inspection :*
ALL CORRECTIONS HAVE BEEN COMPLETED
04/29/2009 BUILDING - PROGRESS Not ready for Inspection IVRS - Inspection :*
12/10/2008 BUILDING - PROGRESS Partial Approval 1) FRONT FAMILY ROOM (ENCLOSED CARPORT)
1A) ENCLOSED CARPORT BUILT CIRCA 1986. STRUCTURALLY SOUND PER ADOPTED CODES AT THAT TIME.
1B) ADDED LIGHT OUTLET ON EXTERIOR ABOVE SLIDING DOOR WILL NEED TO BE OPENED UP FOR VERIFICATION OF ELECTRIC COMPLIANCE.

2) REAR FAMILY ROOM
2A) THIS FAMILY ROOM CONSTRUCTION PRE-DATES 1976. ALL ASPECTS ARE IN GENERAL COMPLIANCE WITH CODES USED AT THAT TIME. NO SUBSTANDARD CONDITIONS NOTED AT THIS TIME.

3) SOUTH-EAST PORCH
3A) THIS SMALL PORCH WAS ADDED IN THE EARLY 1990'S. CORRECTIONS WILL BE REQUIRED.
3B) OWNER MAY USE A.35 CLIPS FROM FASCIA TO ALL RAFTERS ALONG THIS SECTION. FASCIA AT SOUTH SIDE WILL REQUIRE A GUSSET PLATE TO EXISTING FASCIA WITH 12 TOTAL HANGER SCREWS OR TICO NAILS. 2" TUBE STEEL POST WILL REQURE AN ADDITIONAL 1/2" BOLT TO SOUTH FASCIA.

4) EAST (REAR) PORCH
4A) THIS PORCH EASILY PREDATES 1976 AND WAS BUILT IN COMPLIANCE WITH THE CODES AT THAT TIME. THERE ARE MINOR MAINTENANCE ISSUES BUT NOTHING THAT WOULD REQUIRE IMMEDIATE CORRECTION AT THIS TIME.

5) UNATTACHED GARAGE
5A) GARAGE WAS BUILT CIRCA 1982 AND WAS DONE FROM A KIT THAT WAS FAIRLY COMMON AT THAT TIME. THERE HAS BEEN SOME DETERIORATION OVER THE YEARS THAT REQUIRES SOME STRUCTURAL CORRECTION.
5B) OWNER MAY INSTALL CABLE COLLAR TIES 4' O.C. STARTING FROM FRONT OF GARAGE. ADDITIONAL PLYWOOD COLLAR TIES WILL NEED TO BE INSTALLED AT BOTTOM OF RIDGE FOR EACH RAFTER SET AFTER THE CABLE TIES HAVE PROPERLY ALIGNED THE BUILDING.
5C) THERE IS SOME MISAPPLIED ROOF SHEATHING FROM 2 OR 3 YEAR OLD WIND DAMAGE THAT WILL NEED TO BE REPAIRED AFTER COLLAR TIES ARE ESTABLISHED.
5D) THE ELECTRICAL SUBPANEL WILL NEED FURTHER EVALUATION AND WILL REQUIRE SOME REPAIRS AFTER THE STRUCTURAL ISSUES ARE RESOLVED.