Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Details

Status:
C of o
Type:
COMMERCIAL ALTERATION
Apply Date:
01/28/2008
Applicant:
INTERTECH ARCHITECTS
Description:
TI:RESTAURANT
Architects:
  • SWAN WAYNE E
Contractors:
  • DI STEFANO BUILDERS INC

Permit Reviews

Permit Number - T08CM00276
Permit Status: C of o
Permit Description: TI:RESTAURANT
Start Date Submittal Complete Date Status  
01/28/2008 PLANS OK TO SUBMIT - 3RD PARTY 01/28/2008 COMPLETED Review Details
01/29/2008 3RD PARTY REVIEW-COMMERCIAL TI 03/10/2008 COMPLETED Review Details
03/10/2008 POST 3RD PARTY REVIEW 03/12/2008 COMPLETED Review Details
03/12/2008 POST 3RD PARTY REVIEW 03/13/2008 COMPLETED Review Details
04/16/2008 3RD PARTY REVIEW-REVISION/OTHER 04/22/2008 COMPLETED Review Details
05/19/2008 3RD PARTY REVIEW-REVISION/OTHER-2ND 09/18/2008 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T08CM00276
Permit Status: C of o
Permit Description: TI:RESTAURANT
Total Outstanding Activity Conditions - 1
Date Name
01/28/2008 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Completed Inspections

Permit Status: C of o
Permit Number: T08CM00276
Permit Description: TI:RESTAURANT
Total Completed Inspections - 30
Date Description Inspector Results Comments
04/25/2008 PLUMBING - ROUGH, SOIL RRICH Approved IVRS - Inspection :*
WATER TEST THRU ROOF ALL AREAS OK
PIPE WRAP PRE-SLAB OK
05/16/2008 FRAMING GDABBS Approved IVRS - Inspection :*
05/19/2008 MECHANICAL - INTERMEDIATE JMILITEL Approved IVRS - Inspection :*
1. DUCTS IN A VENTILATED ATTIC ABOVE ATTIC INSULATION REQUIRED TO BE INSULATED MIN. R8
2. SEE CITY OF TUCSON AMENDMENTS
3. T-STAT HEIGHT TO BE 48"
4. PROVIDE BACKING AROUND CEILING BOXES
5. GREASE DUCTS TO BE WRAPPED WITH 2 LAYERS OF
FIRE WRAP
6. PROVIDE THE REQUIRED HEAT SENSOR AT EACH
TYPE 1 HOOD
05/19/2008 SHEET ROCK NAILING GDABBS Approved IVRS - Inspection :*
06/24/2008 PLUMBING - PROGRESS RRICH Approved IVRS - Inspection :*
CLOSET FLANGES OK
06/30/2008 MECHANICAL - ABOVE CEILING JMILITEL Approved IVRS - Inspection :*
1. OK FOR CEILING TILES
2. WATER HEATER VENT OFFSET NOT TO EXCEED 60 DEG.
3. PROVIDE 1" CLEARANCE TO COMBUSTIBLES
4. PROVIDE FULL LENGTH HANGER RODS ON HOOD
NO SPLICES
5. DO NOT USE PLUMBERS TAPE TO SUPPORT
WATER HEATER VENT
07/08/2008 BUILDING ABOVE CEILING LHANLY Approved IVRS - Inspection :*
07/08/2008 PLUMBING - ABOVE CEILING RRICH Approved IVRS - Inspection :*
07/08/2008 PLUMBING - INTERMEDIATE RRICH Approved IVRS - Inspection :*
09/15/2008 PLUMBING - GAS PRESS TEST FNL RRICH Approved IVRS - Inspection :*
GAS CARD WHEN BOND IS POSTED
09/22/2008 MECHANICAL - HOOD SYSTEMS JMILITEL Approved IVRS - Inspection :*
09/22/2008 PLUMBING - GAS PRESSURE TEST RRICH Approved IVRS - Inspection :*
1. PROVIDE DRAIN FOR BEER TAP DRAIN
2. DRAINS FROM SODA DISPENSER TO HAVE P-TRAP IF OVER 5' WITH PRIMER THEN GLUE FOR PVC SCH40 PER 2006 UPC
INSTALLATION STANDARDS WITH APPROVED SUPPORTS.
3. PROVIDE 6" MINIMUM CRITICAL LEVEL FOR URINAL
FLUSH VALVE
4. SHOW ACCESS FOR WATER HAMMER ARRESTOR
5. SUPPORT ICE MACHINE DRAIN PIPING
09/22/2008 NPPO - FINAL ACONNOR Approved N/A
09/22/2008 LANDSCAPE - FINAL ACONNOR Approved N/A
09/24/2008 HEALTH DEPT - FINAL 724-7908 LANDERSO Approved
09/24/2008 PLUMBING - FINAL RRICH Approved IVRS - Inspection :*
RECEIVED (3) IN HOUSE BACKFLOW CERTIFICATIONS
RECEIVED BACTERIA REPORT FOR POTABLE WATER
09/24/2008 FIRE SPKLR - FINAL LLAKEY Approved
09/25/2008 RIGHT OF WAY - FINAL MCASTRO Approved PER EMAIL
09/26/2008 MECHANICAL - FINAL JMILITEL Approved IVRS - Inspection :*
09/26/2008 MECHANICAL - PROGRESS JMILITEL Approved
09/26/2008 MECHANICAL - HOODS JMILITEL Approved
09/26/2008 ELECTRIC - INTERMEDIATE DSANTACR Approved
09/26/2008 ELECTRIC - ABOVE CEILING DSANTACR Approved
09/26/2008 ELECTRIC - PROGRESS DSANTACR Approved
09/26/2008 ELECTRIC - FINAL DSANTACR Approved IVRS - Inspection :*
09/26/2008 SIGN - FINAL JYBARRA Approved IVRS - Inspection :*
09/26/2008 ENGINEERING - FINAL NKALAHAR Approved PREVIOUS INSPECTION ITEMS ADDRESSED
09/26/2008 FIRE - KITCHEN EXH HOOD FINAL LLAKEY Approved
09/26/2008 FIRE - FINAL LLAKEY Approved
09/29/2008 BUILDING - FINAL GDABBS Approved IVRS - Inspection :*

Documents

File Name Document Type  
C OF O_09-30-2008.TIF CERT OF OCC VIEW
T08CM00276_001.TIF CONSTRPLANS VIEW
T08CM00276_002.TIF CONSTRPLANS VIEW
T08CM00276_003.TIF CONSTRPLANS VIEW
T08CM00276_004.TIF CONSTRPLANS VIEW
T08CM00276_005.TIF CONSTRPLANS VIEW
T08CM00276_006.TIF CONSTRPLANS VIEW
T08CM00276_001.TIF CONSTRPLANS VIEW
T08CM00276_002.TIF CONSTRPLANS VIEW
T08CM00276_003.TIF CONSTRPLANS VIEW
T08CM00276_004.TIF CONSTRPLANS VIEW
T08CM00276_005.TIF CONSTRPLANS VIEW
T08CM00276_006.TIF CONSTRPLANS VIEW
T08CM00276_007.TIF CONSTRPLANS VIEW
T08CM00276_008.TIF CONSTRPLANS VIEW
T08CM00276_009.TIF CONSTRPLANS VIEW
T08CM00276_010.TIF CONSTRPLANS VIEW
T08CM00276_011.TIF CONSTRPLANS VIEW
T08CM00276_012.TIF CONSTRPLANS VIEW
T08CM00276_013.TIF CONSTRPLANS VIEW
T08CM00276_014.TIF CONSTRPLANS VIEW
T08CM00276_015.TIF CONSTRPLANS VIEW
T08CM00276_016.TIF CONSTRPLANS VIEW
T08CM00276_017.TIF CONSTRPLANS VIEW
T08CM00276_018.TIF CONSTRPLANS VIEW
T08CM00276_019.TIF CONSTRPLANS VIEW
T08CM00276_020.TIF CONSTRPLANS VIEW
T08CM00276_021.TIF CONSTRPLANS VIEW
T08CM00276_022.TIF CONSTRPLANS VIEW
001__A-1.TIF CONSTRPLANS VIEW
002__A-3.TIF CONSTRPLANS VIEW
003__F-1.TIF CONSTRPLANS VIEW
004__P-1.TIF CONSTRPLANS VIEW
005__P-2.TIF CONSTRPLANS VIEW
006__P-3.TIF CONSTRPLANS VIEW
007__P-4.TIF CONSTRPLANS VIEW
008__E-2.TIF CONSTRPLANS VIEW
009__E-3.TIF CONSTRPLANS VIEW
None DOCUMENTS VIEW